These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
2. Measurement of Elecsys NT-proBNP in serum, K2 EDTA and heparin plasma. Lippi G, Salvagno GL, Montagnana M, Guidi GC. Clin Biochem; 2007 Jun; 40(9-10):747-8. PubMed ID: 17408609 [Abstract] [Full Text] [Related]
3. Heparin plasma sampling as an alternative to EDTA for BNP determination on the Access-Beckman Coulter--effect of storage at -20 degrees C. Dupuy AM, Terrier N, Dubois M, Boularan AM, Cristol JP. Clin Lab; 2006 Jun; 52(7-8):393-7. PubMed ID: 16955639 [Abstract] [Full Text] [Related]
4. The Effects of Different Blood Sample and Anticoagulant Types on Quantitative Tests of B-Type Natriuretic Peptide. Yin L, Wang Q, Jiang Z, Meng X, Wang Y. Clin Lab; 2024 Jul 01; 70(7):. PubMed ID: 38965954 [Abstract] [Full Text] [Related]
5. Is heparin plasma suitable for the determination of B-type natriuretic peptide on the Beckman-Coulter Access 2? Santos H, Cauliez B, Tron C, Brunel V, Lavoinne A. Clin Chem Lab Med; 2010 Mar 01; 48(3):399-401. PubMed ID: 20113257 [Abstract] [Full Text] [Related]
6. Cardiac peptide stability, aprotinin and room temperature: importance for assessing cardiac function in clinical practice. Buckley MG, Marcus NJ, Yacoub MH. Clin Sci (Lond); 1999 Dec 01; 97(6):689-95. PubMed ID: 10585896 [Abstract] [Full Text] [Related]
7. B-type natriuretic peptide measured in serum--calibration using plasma samples for research purposes. Severo M, Pereira M, Bettencourt P, Gaio R, Azevedo A. Clin Lab; 2011 Dec 01; 57(11-12):1015-9. PubMed ID: 22239036 [Abstract] [Full Text] [Related]
8. EDTA plasma in glass and polyethylene terephthalate tubes is suitable for measurement of B-type natriuretic peptide on the Mindray CL-6000i. Zhao W, Feng G, Wan J, Wang X, Feng J, Zhang W, Yu Y, Pu R, Du Y, Cao Y. Ann Clin Biochem; 2023 Sep 01; 60(5):306-312. PubMed ID: 36823094 [Abstract] [Full Text] [Related]
9. Use of EDTA samples for prothrombin time measurement in patients receiving oral anticoagulants. Horsti J. Haematologica; 2001 Aug 01; 86(8):851-5. PubMed ID: 11522542 [Abstract] [Full Text] [Related]
10. Effects of percutaneous balloon mitral valvuloplasty on plasma B-type natriuretic peptide in rheumatic mitral stenosis with and without atrial fibrillation. Shang YP, Lai L, Chen J, Zhang F, Wang X. J Heart Valve Dis; 2005 Jul 01; 14(4):453-9. PubMed ID: 16116870 [Abstract] [Full Text] [Related]
11. Influence of sample matrix and storage on BNP measurement on the Bayer Advia Centaur. Lippi G, Fortunato A, Salvagno GL, Montagnana M, Soffiati G, Guidi GC. J Clin Lab Anal; 2007 Jul 01; 21(5):293-7. PubMed ID: 17847103 [Abstract] [Full Text] [Related]
12. [Influence of anticoagulant on the plasma level of fifteen biochemical parameters]. Sacchetto E, Ali D, Dumontet E, Le Carrer D, Orsonneau JL, Delaroche O, Bigot-Corbel E. Ann Biol Clin (Paris); 2014 Jul 01; 72(3):337-50. PubMed ID: 24876145 [Abstract] [Full Text] [Related]
13. Use of different anticoagulants in test tubes for analysis of blood lactate concentrations: Part 2. Implications for the proper handling of blood specimens obtained from critically ill patients. Wiese J, Didwania A, Kerzner R, Chernow B. Crit Care Med; 1997 Nov 01; 25(11):1847-50. PubMed ID: 9366768 [Abstract] [Full Text] [Related]
14. UPLC-ESI-QTOF/MS and multivariate data analysis for blood plasma and serum metabolomics: effect of experimental artefacts and anticoagulant. Barri T, Dragsted LO. Anal Chim Acta; 2013 Mar 20; 768():118-28. PubMed ID: 23473258 [Abstract] [Full Text] [Related]
15. Natriuretic peptide response to dynamic exercise in patients with atrial fibrillation. Engelmann MD, Niemann L, Kanstrup IL, Skagen K, Godtfredsen J. Int J Cardiol; 2005 Oct 20; 105(1):31-9. PubMed ID: 16207542 [Abstract] [Full Text] [Related]
16. Abnormal rhythmic oscillations of atrial natriuretic peptide and brain natriuretic peptide in heart failure. Bentzen H, Pedersen RS, Pedersen HB, Nyvad O, Pedersen EB. Clin Sci (Lond); 2003 Mar 20; 104(3):303-12. PubMed ID: 12605591 [Abstract] [Full Text] [Related]
17. Daily dialyses decrease plasma levels of brain natriuretic peptide (BNP), a biomarker of left ventricular dysfunction. Odar-Cederlöf I, Bjellerup P, Williams A, Blagg CR, Twardowski Z, Ting G, Kjellstrand CM. Hemodial Int; 2006 Oct 20; 10(4):394-8. PubMed ID: 17014518 [Abstract] [Full Text] [Related]
18. Right or wrong sample received for coagulation testing? Tentative algorithms for detection of an incorrect type of sample. Lippi G, Salvagno GL, Adcock DM, Gelati M, Guidi GC, Favaloro EJ. Int J Lab Hematol; 2010 Feb 20; 32(1 Pt 2):132-8. PubMed ID: 19220524 [Abstract] [Full Text] [Related]
19. Comparable increase of B-type natriuretic peptide and amino-terminal pro-B-type natriuretic peptide levels in patients with severe sepsis, septic shock, and acute heart failure. Rudiger A, Gasser S, Fischler M, Hornemann T, von Eckardstein A, Maggiorini M. Crit Care Med; 2006 Aug 20; 34(8):2140-4. PubMed ID: 16763507 [Abstract] [Full Text] [Related]
20. Influence of sample collection and storage on the detection of platelet factor 4-heparin antibodies. Krakow EF, Goudar R, Petzold E, Suvarna S, Last M, Welsby IJ, Ortel TL, Arepally GM. Am J Clin Pathol; 2007 Jul 20; 128(1):150-5. PubMed ID: 17580283 [Abstract] [Full Text] [Related] Page: [Next] [New Search]