These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
112 related items for PubMed ID: 19958856
21. Aortic counterpulsation: a review of the hemodynamic effects and indications for use. Santa-Cruz RA, Cohen MG, Ohman EM. Catheter Cardiovasc Interv; 2006 Jan; 67(1):68-77. PubMed ID: 16342217 [Abstract] [Full Text] [Related]
22. Preoperative intraaortic balloon pump enhances cardiac performance and improves the outcome of redo CABG. Christenson JT, Badel P, Simonet F, Schmuziger M. Ann Thorac Surg; 1997 Nov; 64(5):1237-44. PubMed ID: 9386685 [Abstract] [Full Text] [Related]
23. A prospective, randomized clinical trial of hemodynamic support with Impella 2.5 versus intra-aortic balloon pump in patients undergoing high-risk percutaneous coronary intervention: the PROTECT II study. O'Neill WW, Kleiman NS, Moses J, Henriques JP, Dixon S, Massaro J, Palacios I, Maini B, Mulukutla S, Dzavík V, Popma J, Douglas PS, Ohman M. Circulation; 2012 Oct 02; 126(14):1717-27. PubMed ID: 22935569 [Abstract] [Full Text] [Related]
24. Aggressive management of acute myocardial infarction: successful outcome in an older patient with cardiogenic shock. Tsao YT, Wu CJ, Lin SL, Liu CP, Tak T. Singapore Med J; 2007 Apr 02; 48(4):350-3. PubMed ID: 17384884 [Abstract] [Full Text] [Related]
25. Effects of intra-aortic balloon counterpulsation on coronary pressure in patients with stenotic coronary arteries. Yoshitani H, Akasaka T, Kaji S, Kawamoto T, Kume T, Neishi Y, Koyama Y, Yoshida K. Am Heart J; 2007 Oct 02; 154(4):725-31. PubMed ID: 17893000 [Abstract] [Full Text] [Related]
26. Intraaortic balloon pumping in patients with right ventricular insufficiency after cardiac surgery: parameters to predict failure of IABP Support. Boeken U, Feindt P, Litmathe J, Kurt M, Gams E. Thorac Cardiovasc Surg; 2009 Sep 02; 57(6):324-8. PubMed ID: 19707972 [Abstract] [Full Text] [Related]
27. Clinical and hemodynamic criteria for use of the intra-aortic balloon pump in patients requiring cardiac surgery. Bolooki H, Williams W, Thurer RJ, Vargas A, Kaiser GA, Mack F, Ghahramani AR. J Thorac Cardiovasc Surg; 1976 Nov 02; 72(5):756-68. PubMed ID: 979316 [Abstract] [Full Text] [Related]
28. [Off-pump coronary bypass grafting following percutaneous angioplasty and intra-aortic balloon pumping insertion in a patient with severe peripheral vascular disease]. Umeda Y, Kato T, Azuma K, Murakawa S. Kyobu Geka; 2008 Mar 02; 61(3):223-5. PubMed ID: 18323189 [Abstract] [Full Text] [Related]
29. Improvement in hemodynamics with a new, larger-volume (50 cc) intra-aortic balloon for high-risk percutaneous coronary intervention. Nair PK, Scolieri S, Lee AB. J Invasive Cardiol; 2011 Apr 02; 23(4):162-6. PubMed ID: 21474851 [Abstract] [Full Text] [Related]
30. Elective versus provisional intra-aortic balloon pumping in high-risk percutaneous transluminal coronary angioplasty. Briguori C, Sarais C, Pagnotta P, Airoldi F, Liistro F, Sgura F, Spanos V, Carlino M, Montorfano M, Di Mario C, Colombo A. Am Heart J; 2003 Apr 02; 145(4):700-7. PubMed ID: 12679768 [Abstract] [Full Text] [Related]
31. A randomized comparison of intra-aortic balloon pumping after primary coronary angioplasty in high risk patients with acute myocardial infarction. van 't Hof AW, Liem AL, de Boer MJ, Hoorntje JC, Suryapranata H, Zijlstra F. Eur Heart J; 1999 May 02; 20(9):659-65. PubMed ID: 10208786 [Abstract] [Full Text] [Related]
32. Prophylactic intra-aortic balloon pump in high-risk patients undergoing coronary artery bypass grafting: a propensity score analysis. Miceli A, Fiorani B, Danesi TH, Melina G, Sinatra R. Interact Cardiovasc Thorac Surg; 2009 Aug 02; 9(2):291-4. PubMed ID: 19359281 [Abstract] [Full Text] [Related]
33. The preoperative intraaortic balloon pump in coronary bypass surgery: a lack of evidence of effectiveness. Baskett RJ, O'Connor GT, Hirsch GM, Ghali WA, Sabadosa KA, Morton JR, Ross CS, Hernandez F, Nugent WC, Lahey SJ, Sisto D, Dacey LJ, Klemperer JD, Helm RE, Maitland A. Am Heart J; 2005 Dec 02; 150(6):1122-7. PubMed ID: 16338247 [Abstract] [Full Text] [Related]
35. Changing practice patterns in the management of acute myocardial infarction complicated by cardiogenic shock: elderly compared with younger patients. Dzavík V, Burton JR, Kee C, Teo KK, Ignaszewski A, Lucas AR, Tymchak WJ. Can J Cardiol; 1998 Jul 01; 14(7):923-30. PubMed ID: 9706277 [Abstract] [Full Text] [Related]
36. Major bleeding complicating contemporary primary percutaneous coronary interventions-incidence, predictors, and prognostic implications. Fuchs S, Kornowski R, Teplitsky I, Brosh D, Lev E, Vaknin-Assa H, Ben-Dor I, Iakobishvili Z, Rechavia E, Battler A, Assali A. Cardiovasc Revasc Med; 2009 Jul 01; 10(2):88-93. PubMed ID: 19327670 [Abstract] [Full Text] [Related]
37. Effect of prolonged intra-aortic balloon pumping in patients with cardiogenic shock following acute myocardial infarction. Li JL, Xue H, Wang BS, Zhang HY, Yin LH, Shun WD, Wu Y, Wang LX. Med Sci Monit; 2007 Jun 01; 13(6):CR270-74. PubMed ID: 17534233 [Abstract] [Full Text] [Related]
38. [The Impella system for mechanical support and myocardial recovery]. Engström AE, de Mol BA, Lagrand WK, Henriques JP. Ned Tijdschr Geneeskd; 2010 Jun 01; 154(45):A2699. PubMed ID: 21118589 [Abstract] [Full Text] [Related]
39. Does current treatment of cardiogenic shock complicating the acute coronary syndromes comply with guidelines? Iakobishvili Z, Behar S, Boyko V, Battler A, Hasdai D. Am Heart J; 2005 Jan 01; 149(1):98-103. PubMed ID: 15660040 [Abstract] [Full Text] [Related]
40. Transbrachial insertion of a 7.5-Fr intra-aortic balloon pump in a severely atherosclerotic patient. Onorati F, Bilotta M, Pezzo F, Impiombato B, Caroleo S, Santangelo E, Renzulli A. Crit Care Med; 2006 Aug 01; 34(8):2231-3. PubMed ID: 16775570 [Abstract] [Full Text] [Related] Page: [Previous] [Next] [New Search]