These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
148 related items for PubMed ID: 20122437
1. Pullout strength of miniscrews placed in anterior mandibles of adult and adolescent dogs: a microcomputed tomographic analysis. Wang Z, Zhao Z, Xue J, Song J, Deng F, Yang P. Am J Orthod Dentofacial Orthop; 2010 Jan; 137(1):100-7. PubMed ID: 20122437 [Abstract] [Full Text] [Related]
2. Insertional torque and axial pull-out strength of mini-implants in mandibles of dogs. Salmória KK, Tanaka OM, Guariza-Filho O, Camargo ES, de Souza LT, Maruo H. Am J Orthod Dentofacial Orthop; 2008 Jun; 133(6):790.e15-22. PubMed ID: 18538236 [Abstract] [Full Text] [Related]
3. Histomorphometric evaluation of cortical bone thickness surrounding miniscrew for orthodontic anchorage. Deguchi T, Yabuuchi T, Hasegawa M, Garetto LP, Roberts WE, Takano-Yamamoto T. Clin Implant Dent Relat Res; 2011 Sep; 13(3):197-205. PubMed ID: 19438949 [Abstract] [Full Text] [Related]
4. Pull-out strength of monocortical screws placed in the maxillae and mandibles of dogs. Huja SS, Litsky AS, Beck FM, Johnson KA, Larsen PE. Am J Orthod Dentofacial Orthop; 2005 Mar; 127(3):307-13. PubMed ID: 15775945 [Abstract] [Full Text] [Related]
6. Effects of pilot hole size and bone density on miniscrew implants' stability. Hung E, Oliver D, Kim KB, Kyung HM, Buschang PH. Clin Implant Dent Relat Res; 2012 Jun; 14(3):454-60. PubMed ID: 20345986 [Abstract] [Full Text] [Related]
12. Correlation between miniscrew stability and bone mineral density in orthodontic patients. Santiago RC, de Paula FO, Fraga MR, Picorelli Assis NM, Vitral RW. Am J Orthod Dentofacial Orthop; 2009 Aug; 136(2):243-50. PubMed ID: 19651355 [Abstract] [Full Text] [Related]
13. Evaluation of the surface characteristics of anodic oxidized miniscrews and their impact on biomechanical stability: An experimental study in beagle dogs. Choi SH, Jang SH, Cha JY, Hwang CJ. Am J Orthod Dentofacial Orthop; 2016 Jan; 149(1):31-8. PubMed ID: 26718375 [Abstract] [Full Text] [Related]
15. Three-dimensional analysis of peri-bone-implant contact of rough-surface miniscrew implants. Ikeda H, Rossouw PE, Campbell PM, Kontogiorgos E, Buschang PH. Am J Orthod Dentofacial Orthop; 2011 Feb; 139(2):e153-63. PubMed ID: 21300226 [Abstract] [Full Text] [Related]
16. Computed tomographic characterization of mini-implant placement pattern and maximum anchorage force in human cadavers. Lemieux G, Hart A, Cheretakis C, Goodmurphy C, Trexler S, McGary C, Retrouvey JM. Am J Orthod Dentofacial Orthop; 2011 Sep; 140(3):356-65. PubMed ID: 21889080 [Abstract] [Full Text] [Related]