These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
398 related items for PubMed ID: 20173575
1. Inappropriate application of Yaşargil aneurysm clips: a new observation and technical remark. Celik O, Niemelä M, Romani R, Hernesniemi J. Neurosurgery; 2010 Mar; 66(3 Suppl Operative):84-7; discussion 87. PubMed ID: 20173575 [Abstract] [Full Text] [Related]
2. The new aneurysm clip system for particularly complex aneurysm surgery: technical note. Krammer MJ, Lumenta CB. Neurosurgery; 2010 Jun; 66(6 Suppl Operative):336-8. PubMed ID: 20489528 [Abstract] [Full Text] [Related]
3. Fenestrated aneurysm clips in the surgical management of anterior communicating artery aneurysms: operative techniques and strategy. Clinical article. Zada G, Christian E, Liu CY, Giannotta SL. Neurosurg Focus; 2009 May; 26(5):E7. PubMed ID: 19409008 [Abstract] [Full Text] [Related]
4. Primary treatment of a blister-like aneurysm with an encircling clip graft: technical case report. Sekula RF, Cohen DB, Quigley MR, Jannetta PJ. Neurosurgery; 2006 Jul; 59(1 Suppl 1):ONSE168; discussion ONSE168. PubMed ID: 16894653 [Abstract] [Full Text] [Related]
5. Complete neck clipping of internal carotid-posterior communicating artery aneurysms using bayonet-shaped aneurysm clips: technical note. Kashimura H, Ogasawara K, Kubo Y, Ogawa A. Neurol Med Chir (Tokyo); 2007 Jun; 47(6):282-4; discussion 284. PubMed ID: 17587783 [Abstract] [Full Text] [Related]
6. Assessment of incomplete clipping of aneurysms intraoperatively by a near-infrared indocyanine green-video angiography (Niicg-Va) integrated microscope. Imizu S, Kato Y, Sangli A, Oguri D, Sano H. Minim Invasive Neurosurg; 2008 Aug; 51(4):199-203. PubMed ID: 18683109 [Abstract] [Full Text] [Related]
8. Clinical application of 16-row multislice computed tomographic angiography in the preoperative and postoperative evaluation of intracranial aneurysms for surgical clipping. Chen W, Yang Y, Qiu J, Peng Y, Xing W. Surg Neurol; 2009 May; 71(5):559-65. PubMed ID: 18786701 [Abstract] [Full Text] [Related]
9. Self-closing Nitinol U-Clips for intracranial arterial microanastomosis: a preliminary experience on seven cases. Ferroli P, Acerbi F, Tringali G, Polvani G, Parati E, Broggi G. Acta Neurochir (Wien); 2009 Aug; 151(8):969-76; discussion 976. PubMed ID: 19444375 [Abstract] [Full Text] [Related]
10. Surgical Treatment of Middle Cerebral Artery Aneurysms Without Using Indocyanine Green Videoangiography Assistance: Retrospective Monocentric Study of 263 Clipped Aneurysms. Hallout S. World Neurosurg; 2015 Oct; 84(4):972-7. PubMed ID: 26074439 [Abstract] [Full Text] [Related]
11. Simulation of and training for cerebral aneurysm clipping with 3-dimensional models. Kimura T, Morita A, Nishimura K, Aiyama H, Itoh H, Fukaya S, Sora S, Ochiai C. Neurosurgery; 2009 Oct; 65(4):719-25; discussion 725-6. PubMed ID: 19834377 [Abstract] [Full Text] [Related]
12. Arterial suturing followed by clip reinforcement with circumferential wrapping for blister-like aneurysms of the internal carotid artery. Joo SP, Kim TS, Moon KS, Kwak HJ, Lee JK, Kim JH, Kim SH. Surg Neurol; 2006 Oct; 66(4):424-8; discussion 428-9. PubMed ID: 17015131 [Abstract] [Full Text] [Related]
13. Usefulness of multislice computerized tomographic angiography in the postoperative evaluation of patients with clipped aneurysms. Gerardin E, Tollard E, Derrey S, Langlois O, Dacher JN, Douvrin F, Freger P, Proust F. Acta Neurochir (Wien); 2010 May; 152(5):793-802. PubMed ID: 19639249 [Abstract] [Full Text] [Related]
14. Assessment of flow in perforating arteries during intracranial aneurysm surgery using intraoperative near-infrared indocyanine green videoangiography. de Oliveira JG, Beck J, Seifert V, Teixeira MJ, Raabe A. Neurosurgery; 2007 Sep; 61(3 Suppl):63-72; discussion 72-3. PubMed ID: 17876226 [Abstract] [Full Text] [Related]
15. Mirroring with Indocyanine Green Angiography in Aneurysm Surgery: Technical Note and Case Presentations. Lee Y, Kim M, Park J, Kim BJ, Son W, Jung S. World Neurosurg; 2019 Dec; 132():e696-e703. PubMed ID: 31421297 [Abstract] [Full Text] [Related]
16. Fenestrated T-bar Clips in Surgical Management of Internal Carotid Artery Aneurysms: Technical Note. Saura H, Kashimura H, Aso K, Matsumoto Y. World Neurosurg; 2018 Sep; 117():1-3. PubMed ID: 29883822 [Abstract] [Full Text] [Related]
18. Microsurgical clipping for recurrent aneurysms after initial endovascular coil embolization. Izumo T, Matsuo T, Morofuji Y, Hiu T, Horie N, Hayashi K, Nagata I. World Neurosurg; 2015 Feb; 83(2):211-8. PubMed ID: 25118057 [Abstract] [Full Text] [Related]
19. Double-clip technique for the microneurosurgical management of very small (< 3 mm) intracranial aneurysms. Kiran NA, Jahromi BR, Velasquez JC, Hijazy F, Goehre F, Kivisaari R, Siangprasertkij C, Munoz Gallegos LF, Lehto H, Hernesniemi J. Neurosurgery; 2015 Mar; 11 Suppl 2():3-7. PubMed ID: 25251196 [Abstract] [Full Text] [Related]
20. Essentials in intraoperative indocyanine green videoangiography assessment for intracranial aneurysm surgery: conclusions from 295 consecutively clipped aneurysms and review of the literature. Roessler K, Krawagna M, Dörfler A, Buchfelder M, Ganslandt O. Neurosurg Focus; 2014 Feb; 36(2):E7. PubMed ID: 24484260 [Abstract] [Full Text] [Related] Page: [Next] [New Search]