These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
197 related items for PubMed ID: 20406767
1. Impact of the indexed effective orifice area on mid-term cardiac-related mortality after aortic valve replacement. Bleiziffer S, Ali A, Hettich IM, Akdere D, Laubender RP, Ruzicka D, Boehm J, Lange R, Eichinger W. Heart; 2010 Jun; 96(11):865-71. PubMed ID: 20406767 [Abstract] [Full Text] [Related]
2. Prosthesis-patient mismatch after transcatheter aortic valve implantation using the Edwards SAPIEN™ prosthesis. Van Linden A, Kempfert J, Blumenstein J, Rastan A, Holzhey D, Lehmann S, Mohr FW, Walther T. Thorac Cardiovasc Surg; 2013 Aug; 61(5):414-20. PubMed ID: 22791205 [Abstract] [Full Text] [Related]
3. [Aortic valve replacement in elderly patients with small aortic annulus; is the indexed effective orifice area important?]. Baba H, Aoki M, Nishimura Y, Hashimoto M, Okawa Y. Kyobu Geka; 2006 Apr; 59(4):329-35. PubMed ID: 16613153 [Abstract] [Full Text] [Related]
4. Patient-prosthesis mismatch does not affect survival following aortic valve replacement. Howell NJ, Keogh BE, Barnet V, Bonser RS, Graham TR, Rooney SJ, Wilson IC, Pagano D. Eur J Cardiothorac Surg; 2006 Jul; 30(1):10-4. PubMed ID: 16723251 [Abstract] [Full Text] [Related]
6. Limitations in the Assessment of Prosthesis-Patient Mismatch. Amorim PA, Diab M, Walther M, Färber G, Hagendorff A, Bonow RO, Doenst T. Thorac Cardiovasc Surg; 2020 Oct; 68(7):550-556. PubMed ID: 30609446 [Abstract] [Full Text] [Related]
7. The fallacy of indexed effective orifice area charts to predict prosthesis-patient mismatch after prosthesis implantation. Vriesendorp MD, De Lind Van Wijngaarden RAF, Head SJ, Kappetein AP, Hickey GL, Rao V, Weissman NJ, Reardon MJ, Moront MG, Sabik JF, Klautz RJM. Eur Heart J Cardiovasc Imaging; 2020 Oct 01; 21(10):1116-1122. PubMed ID: 32243493 [Abstract] [Full Text] [Related]
8. Patient-prosthesis mismatch in patients with aortic stenosis undergoing isolated aortic valve replacement does not affect survival. Howell NJ, Keogh BE, Ray D, Bonser RS, Graham TR, Mascaro J, Rooney SJ, Wilson IC, Pagano D. Ann Thorac Surg; 2010 Jan 01; 89(1):60-4. PubMed ID: 20103206 [Abstract] [Full Text] [Related]
14. Impact of different values of prosthesis-patient mismatch on outcome in male patients with aortic valve replacement. Mannacio VA, Mannacio L, Antignano A, Pinna GB, Giordano R, Mottola M, Iannelli G. J Cardiovasc Med (Hagerstown); 2017 May 01; 18(5):366-373. PubMed ID: 28212136 [Abstract] [Full Text] [Related]
15. Aortic valve replacement with smaller prostheses in elderly patients: does patient prosthetic mismatch affect outcomes? Concistrè G, Dell'aquila A, Pansini S, Corsini B, Costigliolo T, Piccardo A, Gallo A, Passerone G, Regesta T. J Card Surg; 2013 Jul 01; 28(4):341-7. PubMed ID: 23691967 [Abstract] [Full Text] [Related]
16. Prosthesis-Patient Mismatch After Aortic Valve Replacement in the PARTNER 2 Trial and Registry. Ternacle J, Pibarot P, Herrmann HC, Kodali S, Leipsic J, Blanke P, Jaber W, Mack MJ, Clavel MA, Salaun E, Guzzetti E, Annabi MS, Bernier M, Beaudoin J, Khalique OK, Weissman NJ, Douglas P, Bax J, Dahou A, Xu K, Alu M, Rogers E, Leon M, Thourani VH, Abbas AE, Hahn RT. JACC Cardiovasc Interv; 2021 Jul 12; 14(13):1466-1477. PubMed ID: 34238557 [Abstract] [Full Text] [Related]
17. Impact of valve prosthesis-patient mismatch on intermediate-term outcome and regression of left ventricular mass following aortic valve replacement with mechanical prosthesis. Tao K, Sakata R, Iguro Y, Ueno M, Tanaka Y, Otsuji Y, Tei C. J Card Surg; 2007 Jul 12; 22(6):486-92. PubMed ID: 18039208 [Abstract] [Full Text] [Related]
18. Impact of prosthesis-patient mismatch on the regression of secondary mitral regurgitation after isolated aortic valve replacement with a bioprosthetic valve in patients with severe aortic stenosis. Angeloni E, Melina G, Pibarot P, Benedetto U, Refice S, Ciavarella GM, Roscitano A, Sinatra R, Pepper JR. Circ Cardiovasc Imaging; 2012 Jan 12; 5(1):36-42. PubMed ID: 22138006 [Abstract] [Full Text] [Related]
19. Severe prosthesis-patient mismatch after aortic valve replacement for aortic stenosis: Analysis of risk factors for early and long-term mortality. Mannacio V, Mannacio L, Mango E, Antignano A, Mottola M, Caparrotti S, Musumeci F, Vosa C. J Cardiol; 2017 Jan 12; 69(1):333-339. PubMed ID: 27492659 [Abstract] [Full Text] [Related]
20. [Aortic valve replacement with a small valve prosthesis: a review of clinical and echocardiographic studies for impact of prosthesis-patient mismatch]. Aoyagi S, Yoshikawa K. Nihon Geka Gakkai Zasshi; 2007 Mar 12; 108(2):59-63. PubMed ID: 17405538 [Abstract] [Full Text] [Related] Page: [Next] [New Search]