These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
137 related items for PubMed ID: 20414880
1. A magnetic bead-based serum proteomic fingerprinting method for parallel analytical analysis and micropreparative purification. Wong MY, Yu KO, Poon TC, Ang IL, Law MK, Chan KY, Ng EW, Ngai SM, Sung JJ, Chan HL. Electrophoresis; 2010 May; 31(10):1721-30. PubMed ID: 20414880 [Abstract] [Full Text] [Related]
2. Unravelling in vitro variables of major importance for the outcome of mass spectrometry-based serum proteomics. West-Nørager M, Kelstrup CD, Schou C, Høgdall EV, Høgdall CK, Heegaard NH. J Chromatogr B Analyt Technol Biomed Life Sci; 2007 Feb 15; 847(1):30-7. PubMed ID: 17112795 [Abstract] [Full Text] [Related]
3. Derivatized mesoporous silica beads for MALDI-TOF MS profiling of human plasma and urine. Terracciano R, Pasqua L, Casadonte F, Frascà S, Preianò M, Falcone D, Savino R. Bioconjug Chem; 2009 May 20; 20(5):913-23. PubMed ID: 19338374 [Abstract] [Full Text] [Related]
11. Detection of lung adenocarcinoma using magnetic beads based matrix-assisted laser desorption/ionization time-of-flight mass spectrometry serum protein profiling. Lin XL, Yang SY, Du J, Tian YX, Bu LN, Huo SF, Wang FP, Nan YD. Chin Med J (Engl); 2010 Jan 05; 123(1):34-9. PubMed ID: 20137572 [Abstract] [Full Text] [Related]
12. Reproducibility of serum protein profiling by systematic assessment using solid-phase extraction and matrix-assisted laser desorption/ionization mass spectrometry. Callesen AK, Christensen Rd, Madsen JS, Vach W, Zapico E, Cold S, Jørgensen PE, Mogensen O, Kruse TA, Jensen ON. Rapid Commun Mass Spectrom; 2008 Jan 05; 22(3):291-300. PubMed ID: 18181248 [Abstract] [Full Text] [Related]
13. A peptide concentration and purification method for protein characterization in the subpicomole range using matrix assisted laser desorption/ionization-postsource decay (MALDI-PSD) sequencing. Gevaert K, Demol H, Sklyarova T, Vandekerckhove J, Houthaeve T. Electrophoresis; 1998 May 05; 19(6):909-17. PubMed ID: 9638937 [Abstract] [Full Text] [Related]
14. Effects of pretreatment protocols on human amniotic fluid protein profiling with SELDI-TOF MS using protein chips and magnetic beads. Deng B, Dong Z, Liu Y, Wang C, Liu J, Wang C, Qu X. Clin Chim Acta; 2010 Aug 05; 411(15-16):1051-7. PubMed ID: 20361951 [Abstract] [Full Text] [Related]