These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
160 related items for PubMed ID: 20424884
1. Limitations of rapid myelin water quantification using 3D bSSFP. Lenz C, Klarhöfer M, Scheffler K. MAGMA; 2010 Jun; 23(3):139-51. PubMed ID: 20424884 [Abstract] [Full Text] [Related]
2. Using 3D spatial correlations to improve the noise robustness of multi component analysis of 3D multi echo quantitative T2 relaxometry data. Kumar D, Hariharan H, Faizy TD, Borchert P, Siemonsen S, Fiehler J, Reddy R, Sedlacik J. Neuroimage; 2018 Sep; 178():583-601. PubMed ID: 29763672 [Abstract] [Full Text] [Related]
3. Non-negative least squares computation for in vivo myelin mapping using simulated multi-echo spin-echo T2 decay data. Wiggermann V, Vavasour IM, Kolind SH, MacKay AL, Helms G, Rauscher A. NMR Biomed; 2020 Dec; 33(12):e4277. PubMed ID: 32124505 [Abstract] [Full Text] [Related]
4. Improved determination of the myelin water fraction in human brain using magnetic resonance imaging through Bayesian analysis of mcDESPOT. Bouhrara M, Spencer RG. Neuroimage; 2016 Feb 15; 127():456-471. PubMed ID: 26499810 [Abstract] [Full Text] [Related]
5. Conversion map from quantitative parameter mapping to myelin water fraction: comparison with R1·R2* and myelin water fraction in white matter. Kitano S, Kanazawa Y, Harada M, Taniguchi Y, Hayashi H, Matsumoto Y, Ito K, Bito Y, Haga A. MAGMA; 2024 Oct 15; 37(5):887-898. PubMed ID: 38581455 [Abstract] [Full Text] [Related]
6. Variable flip angle echo planar time-resolved imaging (vFA-EPTI) for fast high-resolution gradient echo myelin water imaging. Dong Z, Wang F, Chan KS, Reese TG, Bilgic B, Marques JP, Setsompop K. Neuroimage; 2021 May 15; 232():117897. PubMed ID: 33621694 [Abstract] [Full Text] [Related]
7. Transceive phase mapping using the PLANET method and its application for conductivity mapping in the brain. Gavazzi S, Shcherbakova Y, Bartels LW, Stalpers LJA, Lagendijk JJW, Crezee H, van den Berg CAT, van Lier ALHMW. Magn Reson Med; 2020 Feb 15; 83(2):590-607. PubMed ID: 31483520 [Abstract] [Full Text] [Related]
8. Field inhomogeneity correction for gradient echo myelin water fraction imaging. Alonso-Ortiz E, Levesque IR, Paquin R, Pike GB. Magn Reson Med; 2017 Jul 15; 78(1):49-57. PubMed ID: 27416957 [Abstract] [Full Text] [Related]
10. Multi-compartment relaxometry and diffusion informed myelin water imaging - Promises and challenges of new gradient echo myelin water imaging methods. Chan KS, Marques JP. Neuroimage; 2020 Nov 01; 221():117159. PubMed ID: 32663644 [Abstract] [Full Text] [Related]
11. Quantitative magnetization transfer imaging using balanced SSFP. Gloor M, Scheffler K, Bieri O. Magn Reson Med; 2008 Sep 01; 60(3):691-700. PubMed ID: 18727085 [Abstract] [Full Text] [Related]
12. Myelin water imaging from multi-echo T2 MR relaxometry data using a joint sparsity constraint. Nagtegaal M, Koken P, Amthor T, de Bresser J, Mädler B, Vos F, Doneva M. Neuroimage; 2020 Oct 01; 219():117014. PubMed ID: 32534123 [Abstract] [Full Text] [Related]
13. Data-driven myelin water imaging based on T1 and T2 relaxometry. Piredda GF, Hilbert T, Ravano V, Canales-Rodríguez EJ, Pizzolato M, Meuli R, Thiran JP, Richiardi J, Kober T. NMR Biomed; 2022 Jul 01; 35(7):e4668. PubMed ID: 34936147 [Abstract] [Full Text] [Related]
14. Feasibility of MRI Quantification of Myelin Water Fraction in the Fetal Guinea Pig Brain. Sethi S, Friesen-Waldner LJ, Wade TP, Courchesne M, Nygard K, Sarr O, Sutherland B, Regnault TRH, McKenzie CA. J Magn Reson Imaging; 2023 Jun 01; 57(6):1856-1864. PubMed ID: 36239714 [Abstract] [Full Text] [Related]
15. Multi-gradient-echo myelin water fraction imaging: Comparison to the multi-echo-spin-echo technique. Alonso-Ortiz E, Levesque IR, Pike GB. Magn Reson Med; 2018 Mar 01; 79(3):1439-1446. PubMed ID: 28656649 [Abstract] [Full Text] [Related]
16. Inherent and unpredictable bias in multi-component DESPOT myelin water fraction estimation. West DJ, Teixeira RPAG, Wood TC, Hajnal JV, Tournier JD, Malik SJ. Neuroimage; 2019 Jul 15; 195():78-88. PubMed ID: 30930311 [Abstract] [Full Text] [Related]
17. Echo time-range effects on gradient-echo based myelin water fraction mapping at 3T. Lee H, Nam Y, Kim DH. Magn Reson Med; 2019 Apr 15; 81(4):2799-2807. PubMed ID: 30346049 [Abstract] [Full Text] [Related]
18. In vivo multi-slice mapping of myelin water content using T2* decay. Hwang D, Kim DH, Du YP. Neuroimage; 2010 Aug 01; 52(1):198-204. PubMed ID: 20398770 [Abstract] [Full Text] [Related]
19. Applicability and reproducibility of 2D multi-slice GRASE myelin water fraction with varying acquisition acceleration. Drenthen GS, Backes WH, Aldenkamp AP, Jansen JFA. Neuroimage; 2019 Jul 15; 195():333-339. PubMed ID: 30965132 [Abstract] [Full Text] [Related]