These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


1025 related items for PubMed ID: 20506236

  • 1. Series of transcatheter valve-in-valve implantations in high-risk patients with degenerated bioprostheses in aortic and mitral position.
    Seiffert M, Franzen O, Conradi L, Baldus S, Schirmer J, Meinertz T, Reichenspurner H, Treede H.
    Catheter Cardiovasc Interv; 2010 Oct 01; 76(4):608-15. PubMed ID: 20506236
    [Abstract] [Full Text] [Related]

  • 2. Transcatheter mitral valve-in-valve implantation in patients with degenerated bioprostheses.
    Seiffert M, Conradi L, Baldus S, Schirmer J, Knap M, Blankenberg S, Reichenspurner H, Treede H.
    JACC Cardiovasc Interv; 2012 Mar 01; 5(3):341-9. PubMed ID: 22440502
    [Abstract] [Full Text] [Related]

  • 3. Transcatheter transapical mitral valve-in-valve implantations for a failed bioprosthesis: a case series.
    Cheung AW, Gurvitch R, Ye J, Wood D, Lichtenstein SV, Thompson C, Webb JG.
    J Thorac Cardiovasc Surg; 2011 Mar 01; 141(3):711-5. PubMed ID: 21269643
    [Abstract] [Full Text] [Related]

  • 4. Impact of patient-prosthesis mismatch after transcatheter aortic valve-in-valve implantation in degenerated bioprostheses.
    Seiffert M, Conradi L, Baldus S, Knap M, Schirmer J, Franzen O, Koschyk D, Meinertz T, Reichenspurner H, Treede H.
    J Thorac Cardiovasc Surg; 2012 Mar 01; 143(3):617-24. PubMed ID: 22169448
    [Abstract] [Full Text] [Related]

  • 5. Valve-in-Valve Procedures in Failing Biological Xenografts Using a Novel Balloon-Expandable Device: Experience in Aortic, Mitral, and Tricuspid Positions.
    Schaefer A, Conradi L, Seiffert M, Lubos E, Blankenberg S, Reichenspurner H, Schaefer U, Treede H.
    Thorac Cardiovasc Surg; 2016 Aug 01; 64(5):366-73. PubMed ID: 26277078
    [Abstract] [Full Text] [Related]

  • 6. Transcatheter aortic valve implantation for treatment of patients with degenerated aortic bioprostheses--valve-in-valve technique.
    Gotzmann M, Mügge A, Bojara W.
    Catheter Cardiovasc Interv; 2010 Dec 01; 76(7):1000-6. PubMed ID: 20824744
    [Abstract] [Full Text] [Related]

  • 7. Transcatheter aortic valve implantation for treatment of failing homograft with preexisting mechanical mitral prosthesis.
    Attia R, Bapat V.
    Catheter Cardiovasc Interv; 2013 Aug 01; 82(2):324-7. PubMed ID: 22120953
    [Abstract] [Full Text] [Related]

  • 8. Transcatheter Aortic and Mitral Valve-in-Valve Implantation for Failed Surgical Bioprosthetic Valves: An 8-Year Single-Center Experience.
    Ye J, Cheung A, Yamashita M, Wood D, Peng D, Gao M, Thompson CR, Munt B, Moss RR, Blanke P, Leipsic J, Dvir D, Webb JG.
    JACC Cardiovasc Interv; 2015 Nov 01; 8(13):1735-44. PubMed ID: 26476608
    [Abstract] [Full Text] [Related]

  • 9. Transfemoral implantation of transcatheter heart valves after deterioration of mitral bioprosthesis or previous ring annuloplasty.
    Bouleti C, Fassa AA, Himbert D, Brochet E, Ducrocq G, Nejjari M, Ghodbane W, Depoix JP, Nataf P, Vahanian A.
    JACC Cardiovasc Interv; 2015 Jan 01; 8(1 Pt A):83-91. PubMed ID: 25616821
    [Abstract] [Full Text] [Related]

  • 10. Percutaneous Transvenous Transseptal Transcatheter Valve Implantation in Failed Bioprosthetic Mitral Valves, Ring Annuloplasty, and Severe Mitral Annular Calcification.
    Eleid MF, Cabalka AK, Williams MR, Whisenant BK, Alli OO, Fam N, Pollak PM, Barrow F, Malouf JF, Nishimura RA, Joyce LD, Dearani JA, Rihal CS.
    JACC Cardiovasc Interv; 2016 Jun 13; 9(11):1161-74. PubMed ID: 27085576
    [Abstract] [Full Text] [Related]

  • 11. Use of transcatheter heart valves for a valve-in-valve implantation in patients with degenerated aortic bioprosthesis: technical considerations and results.
    Bapat V, Attia R, Redwood S, Hancock J, Wilson K, Young C, Thomas M.
    J Thorac Cardiovasc Surg; 2012 Dec 13; 144(6):1372-9; discussion 1379-80. PubMed ID: 23140962
    [Abstract] [Full Text] [Related]

  • 12. Valve-in-valve transcatheter aortic valve implantation for degenerated bioprosthetic heart valves.
    Eggebrecht H, Schäfer U, Treede H, Boekstegers P, Babin-Ebell J, Ferrari M, Möllmann H, Baumgartner H, Carrel T, Kahlert P, Lange P, Walther T, Erbel R, Mehta RH, Thielmann M.
    JACC Cardiovasc Interv; 2011 Nov 13; 4(11):1218-27. PubMed ID: 22115663
    [Abstract] [Full Text] [Related]

  • 13. Use of balloon expandable transcatheter valves for valve-in-valve implantation in patients with degenerative stentless aortic bioprostheses: Technical considerations and results.
    Bapat V, Davies W, Attia R, Hancock J, Bolter K, Young C, Redwood S, Thomas M.
    J Thorac Cardiovasc Surg; 2014 Sep 13; 148(3):917-22; discussion 922-4. PubMed ID: 25037622
    [Abstract] [Full Text] [Related]

  • 14. Transcatheter aortic valve implantation for high risk patients with severe aortic stenosis using the Edwards Sapien balloon-expandable bioprosthesis: a single centre study with immediate and medium-term outcomes.
    Osten MD, Feindel C, Greutmann M, Chamberlain K, Meineri M, Rubin B, Mezody M, Ivanov J, Butany J, Horlick EM.
    Catheter Cardiovasc Interv; 2010 Mar 01; 75(4):475-85. PubMed ID: 19937781
    [Abstract] [Full Text] [Related]

  • 15. Reoperative "valve-in-valve" transapical transcatheter mitral valve replacement in a high-risk patient with a recent transapical transcatheter aortic valve replacement and a degenerated bioprosthetic mitral valve.
    de Biasi AR, Wong SC, Salemi A.
    J Thorac Cardiovasc Surg; 2014 Nov 01; 148(5):e209-10. PubMed ID: 25135239
    [No Abstract] [Full Text] [Related]

  • 16. Transapical transcatheter valve-in-valve implantation for deteriorated mitral valve bioprostheses.
    Wilbring M, Alexiou K, Tugtekin SM, Sill B, Hammer P, Schmidt T, Simonis G, Matschke K, Kappert U.
    Ann Thorac Surg; 2013 Jan 01; 95(1):111-7. PubMed ID: 23063191
    [Abstract] [Full Text] [Related]

  • 17. Initial German experience with transapical implantation of a second-generation transcatheter heart valve for the treatment of aortic regurgitation.
    Seiffert M, Bader R, Kappert U, Rastan A, Krapf S, Bleiziffer S, Hofmann S, Arnold M, Kallenbach K, Conradi L, Schlingloff F, Wilbring M, Schäfer U, Diemert P, Treede H.
    JACC Cardiovasc Interv; 2014 Oct 01; 7(10):1168-74. PubMed ID: 25129672
    [Abstract] [Full Text] [Related]

  • 18. Valve-in-valve implantation of Medtronic CoreValve prosthesis in patients with failing bioprosthetic aortic valves.
    Linke A, Woitek F, Merx MW, Schiefer C, Möbius-Winkler S, Holzhey D, Rastan A, Ender J, Walther T, Kelm M, Mohr FW, Schuler G.
    Circ Cardiovasc Interv; 2012 Oct 01; 5(5):689-97. PubMed ID: 23048050
    [Abstract] [Full Text] [Related]

  • 19. First in human implantation of the mechanical expanding Lotus® valve in degenerated surgical valves in mitral position.
    Schaefer U, Conradi L, Lubos E, Deuschl F, Schofer N, Seiffert M, Treede H, Schirmer J, Reichenspurner H, Blankenberg S.
    Catheter Cardiovasc Interv; 2015 Dec 01; 86(7):1280-6. PubMed ID: 26389782
    [Abstract] [Full Text] [Related]

  • 20. Early clinical outcome of aortic transcatheter valve-in-valve implantation in the Nordic countries.
    Ihlberg L, Nissen H, Nielsen NE, Rück A, Busund R, Klaarborg KE, Soendergaard L, Harnek J, Miettinen H, Eskola M, Wahba A, Laine M.
    J Thorac Cardiovasc Surg; 2013 Nov 01; 146(5):1047-54; discussion 1054. PubMed ID: 23998786
    [Abstract] [Full Text] [Related]


    Page: [Next] [New Search]
    of 52.