These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
1049 related items for PubMed ID: 20509731
1. Localization of cervical and cervicomedullary stimulation leads for pain treatment using median nerve somatosensory evoked potential collision testing. Balzer JR, Tomycz ND, Crammond DJ, Habeych M, Thirumala PD, Urgo L, Moossy JJ. J Neurosurg; 2011 Jan; 114(1):200-5. PubMed ID: 20509731 [Abstract] [Full Text] [Related]
3. Multimodal, Intraoperative Monitoring during Paddle Lead Placement for Cervicothoracic Spinal Cord Stimulation. Choi JG, Ha SW, Son BC. Stereotact Funct Neurosurg; 2015 Feb; 93(4):271-81. PubMed ID: 26183282 [Abstract] [Full Text] [Related]
4. Upper-limb somatosensory evoked potential monitoring in lumbosacral spine surgery: a prognostic marker for position-related ulnar nerve injury. Chung I, Glow JA, Dimopoulos V, Walid MS, Smisson HF, Johnston KW, Robinson JS, Grigorian AA. Spine J; 2009 Apr; 9(4):287-95. PubMed ID: 18684675 [Abstract] [Full Text] [Related]
5. The use of intraoperative electrophysiology for the placement of spinal cord stimulator paddle leads under general anesthesia. Mammis A, Mogilner AY. Neurosurgery; 2012 Jun; 70(2 Suppl Operative):230-6. PubMed ID: 21869720 [Abstract] [Full Text] [Related]
6. "Threshold-level" multipulse transcranial electrical stimulation of motor cortex for intraoperative monitoring of spinal motor tracts: description of method and comparison to somatosensory evoked potential monitoring. Calancie B, Harris W, Broton JG, Alexeeva N, Green BA. J Neurosurg; 1998 Mar; 88(3):457-70. PubMed ID: 9488299 [Abstract] [Full Text] [Related]
7. Intraoperative changes in transcranial motor evoked potentials and somatosensory evoked potentials predicting outcome in children with intramedullary spinal cord tumors. Cheng JS, Ivan ME, Stapleton CJ, Quinones-Hinojosa A, Gupta N, Auguste KI. J Neurosurg Pediatr; 2014 Jun; 13(6):591-9. PubMed ID: 24702615 [Abstract] [Full Text] [Related]
8. Neurophysiological monitoring of spinal cord function during instrumented anterior cervical fusion. Bose B, Sestokas AK, Schwartz DM. Spine J; 2004 Jun; 4(2):202-7. PubMed ID: 15016399 [Abstract] [Full Text] [Related]
9. Intraoperative somatosensory evoked potential monitoring during anterior cervical discectomy and fusion in nonmyelopathic patients--a review of 1,039 cases. Smith PN, Balzer JR, Khan MH, Davis RA, Crammond D, Welch WC, Gerszten P, Sclabassi RJ, Kang JD, Donaldson WF. Spine J; 2007 Jun; 7(1):83-7. PubMed ID: 17197338 [Abstract] [Full Text] [Related]
10. The usefulness of intraoperative neurophysiological monitoring in cervical spine surgery: a retrospective analysis of 200 consecutive patients. Li F, Gorji R, Allott G, Modes K, Lunn R, Yang ZJ. J Neurosurg Anesthesiol; 2012 Jul; 24(3):185-90. PubMed ID: 22525331 [Abstract] [Full Text] [Related]
11. Utility of neurophysiological monitoring using dorsal column mapping in intramedullary spinal cord surgery. Yanni DS, Ulkatan S, Deletis V, Barrenechea IJ, Sen C, Perin NI. J Neurosurg Spine; 2010 Jun; 12(6):623-8. PubMed ID: 20515347 [Abstract] [Full Text] [Related]
12. Intraoperative somatosensory evoked potential monitoring during cervical spine corpectomy surgery: experience with 508 cases. Khan MH, Smith PN, Balzer JR, Crammond D, Welch WC, Gerszten P, Sclabassi RJ, Kang JD, Donaldson WF. Spine (Phila Pa 1976); 2006 Feb 15; 31(4):E105-13. PubMed ID: 16481938 [Abstract] [Full Text] [Related]
13. Somatosensory evoked potential monitoring detection of carotid compression during ACDF surgery in a patient with a vascularly isolated hemisphere. Legatt AD, Laarakker AS, Nakhla JP, Nasser R, Altschul DJ. J Neurosurg Spine; 2016 Nov 15; 25(5):566-571. PubMed ID: 27285667 [Abstract] [Full Text] [Related]
14. Intraoperative decrease in amplitude of somatosensory-evoked potentials of the lower extremities with interbody fusion cage placement during lumbar fusion surgery. Duncan JW, Bailey RA, Baena R. Spine (Phila Pa 1976); 2012 Sep 15; 37(20):E1290-5. PubMed ID: 22614796 [Abstract] [Full Text] [Related]
16. [Somatosensory evoked potential]. Fukuda S. Masui; 2006 Mar 15; 55(3):280-93. PubMed ID: 16541777 [Abstract] [Full Text] [Related]
17. Neurophysiological Monitoring During Spinal Cord Stimulator Placement Surgery. Tamkus AA, Scott AF, Khan FR. Neuromodulation; 2015 Aug 15; 18(6):460-4; discussion 464. PubMed ID: 25677059 [Abstract] [Full Text] [Related]
18. Causal factors for position-related SSEP changes in spinal surgery. Silverstein JW, Matthews E, Mermelstein LE, DeWal H. Eur Spine J; 2016 Oct 15; 25(10):3208-3213. PubMed ID: 27209584 [Abstract] [Full Text] [Related]
19. Efficacy and limitations of intraoperative spinal cord monitoring using nasopharyngeal tube electrodes. Yamamoto N, Kobashi H, Shiba M, Itoh T. J Neurosurg Spine; 2010 Aug 15; 13(2):200-10. PubMed ID: 20672955 [Abstract] [Full Text] [Related]
20. [Functional studies of the spinal cord in chronic stenosing diseases of the cervical spine using somatosensory evoked potentials]. Kraus R, Christophis P. Zentralbl Neurochir; 1994 Aug 15; 55(2):96-101. PubMed ID: 7941832 [Abstract] [Full Text] [Related] Page: [Next] [New Search]