These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
343 related items for PubMed ID: 2051261
1. Plastics, endotoxins, and the Limulus amebocyte lysate test. Roslansky PF, Dawson ME, Novitsky TJ. J Parenter Sci Technol; 1991; 45(2):83-7. PubMed ID: 2051261 [Abstract] [Full Text] [Related]
2. Recovery of endotoxin preparations from the surface of glass capillary tubes. Ludwig JD, Avis KE. J Parenter Sci Technol; 1989; 43(6):276-8. PubMed ID: 2600733 [Abstract] [Full Text] [Related]
3. Collaborative study of a control standard endotoxin using the Limulus amebocyte (gel-clot) test. Adner N, Flink O, Nystrand R, Pihl B, Vegis P. J Parenter Sci Technol; 1991; 45(2):88-93. PubMed ID: 2051262 [Abstract] [Full Text] [Related]
4. Endotoxins and medical devices. Ross VC, Twohy CW. Prog Clin Biol Res; 1985; 189():267-81. PubMed ID: 4048209 [Abstract] [Full Text] [Related]
5. The Limulus amebocyte lysate endotoxin assay: current status. Pearson FC. Am J Med Technol; 1979 Aug; 45(8):704-9. PubMed ID: 573551 [Abstract] [Full Text] [Related]
6. [Quantitative endotoxin determination. Automated kinetic Limulus amebocyte lysate microtiter test with measurement of sample-related interferences]. Ditter B, Becker KP, Urbaschek R, Urbaschek B. Arzneimittelforschung; 1983 Aug; 33(5):681-7. PubMed ID: 6683544 [Abstract] [Full Text] [Related]
7. Clinical utility of the Limulus amebocyte lysate (LAL) test. Elin RJ, Hosseini J. Prog Clin Biol Res; 1985 Aug; 189():307-27. PubMed ID: 4048211 [Abstract] [Full Text] [Related]
8. Application of LAL for detection of endotoxin in antibiotic preparations. Harrison SJ, Tsuji K, Enzinger RM. Prog Clin Biol Res; 1979 Aug; 29():353-65. PubMed ID: 388463 [Abstract] [Full Text] [Related]
9. The effect of refrigeration and mixing on detection of endotoxin in parenteral drugs using the Limulus Amebocyte Lysate (LAL) test. Guilfoyle DE, Yager JF, Carito SL. J Parenter Sci Technol; 1989 Aug; 43(4):183-7. PubMed ID: 2769526 [Abstract] [Full Text] [Related]
10. [The effect of mistletoe lectins on the limulus amebocyte lysate test]. Scheer R. Arzneimittelforschung; 1993 Jul; 43(7):795-800. PubMed ID: 8369015 [Abstract] [Full Text] [Related]
11. [Application of a bacterial endotoxin test for parenteral drugs]. Ogawa Y. Eisei Shikenjo Hokoku; 1994 Jul; (112):209-11. PubMed ID: 8854936 [Abstract] [Full Text] [Related]
12. Automated limulus amebocyte lysate (LAL) test for endotoxin analysis using a new Toxinometer ET-201. Oishi H, Takaoka A, Hatayama Y, Matsuo T, Sakata Y. J Parenter Sci Technol; 1985 Jul; 39(5):194-9. PubMed ID: 4067768 [No Abstract] [Full Text] [Related]
13. Guideline for validation of the LAL test as an end-product endotoxin test for human and biological drug products. Munson TE. Prog Clin Biol Res; 1985 Jul; 189():211-20. PubMed ID: 4048205 [Abstract] [Full Text] [Related]
14. Endotoxin concentration in contact lens storage cases. Fulk GW, Davis RD, Abbey MM. J Am Optom Assoc; 1997 May; 68(5):296-300. PubMed ID: 9170795 [Abstract] [Full Text] [Related]
15. A Validation Study of the Limulus Amebocyte Lysate Test as an End-Product Endotoxin Test for Polyvalent Horse Snake Antivenom. Sheraba NS, Diab MR, Yassin AS, Amin MA, Zedan HH. PDA J Pharm Sci Technol; 2019 May; 73(6):562-571. PubMed ID: 30770487 [Abstract] [Full Text] [Related]
16. Detection of endotoxin in biological products by the limulus test. Cooper JF, Pearson SM. Dev Biol Stand; 1977 May; 34():7-13. PubMed ID: 838151 [Abstract] [Full Text] [Related]
17. Expert system computer program for troubleshooting the gel-clot Limulus amebocyte lysate (LAL) assay. Tsuji K. J Parenter Sci Technol; 1989 May; 43(5):240-5. PubMed ID: 2809932 [Abstract] [Full Text] [Related]
18. [LAL (Limulus Amoebocyte Lysate) test as applied to the safety evaluation of biological preparations]. Aleksandrowicz J, Kudelski Z. Rocz Panstw Zakl Hig; 1997 May; 48(3):275-82. PubMed ID: 9432705 [Abstract] [Full Text] [Related]
19. [Use of the Limulus test (LAL) to detect endotoxins]. Kaca W. Postepy Hig Med Dosw; 1996 May; 50(5):447-57. PubMed ID: 9072761 [Abstract] [Full Text] [Related]
20. Optimization of a chromogenic Limulus amebocyte lysate (LAL) assay for automated endotoxin detection. Bussey DM, Tsuji K. J Parenter Sci Technol; 1984 May; 38(6):228-33. PubMed ID: 6527205 [No Abstract] [Full Text] [Related] Page: [Next] [New Search]