These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


200 related items for PubMed ID: 20545670

  • 1. Dialysate and blood temperature during hemodialysis: comparing isothermic dialysis with a single-pass batch system.
    Dhondt A, Eloot S, Verbeke F, Vanholder R.
    Artif Organs; 2010 Dec; 34(12):1132-7. PubMed ID: 20545670
    [Abstract] [Full Text] [Related]

  • 2. Temperature and concentration distribution within the Genius dialysate container.
    Eloot S, Dhondt A, Vierendeels J, De Wachter D, Verdonck P, Vanholder R.
    Nephrol Dial Transplant; 2007 Oct; 22(10):2962-9. PubMed ID: 17567650
    [Abstract] [Full Text] [Related]

  • 3. Effect of dialysate temperature on hemodynamic stability among hemodialysis patients.
    Azar AT.
    Saudi J Kidney Dis Transpl; 2009 Jul; 20(4):596-603. PubMed ID: 19587499
    [Abstract] [Full Text] [Related]

  • 4. Studies on dialysate mixing in the Genius single-pass batch system for hemodialysis therapy.
    Dhondt AW, Vanholder RC, De Smet RV, Claus SA, Waterloos MA, Glorieux GL, Delanghe JR, Lameire NH.
    Kidney Int; 2003 Apr; 63(4):1540-7. PubMed ID: 12631371
    [Abstract] [Full Text] [Related]

  • 5. Isothermic hemodialysis and ultrafiltration.
    Rosales LM, Schneditz D, Morris AT, Rahmati S, Levin NW.
    Am J Kidney Dis; 2000 Aug; 36(2):353-61. PubMed ID: 10922314
    [Abstract] [Full Text] [Related]

  • 6. Effect of dialysate temperature on energy balance during hemodialysis: quantification of extracorporeal energy transfer.
    van der Sande FM, Kooman JP, Burema JH, Hameleers P, Kerkhofs AM, Barendregt JM, Leunissen KM.
    Am J Kidney Dis; 1999 Jun; 33(6):1115-21. PubMed ID: 10352200
    [Abstract] [Full Text] [Related]

  • 7. [Temperature dialysate and hemodialysis tolerance].
    Teruel JL, Martins J, Merino JL, Fernández Lucas M, Rivera M, Marcén R, Quereda C, Ortuño J.
    Nefrologia; 2006 Jun; 26(4):461-8. PubMed ID: 17058858
    [Abstract] [Full Text] [Related]

  • 8. Dialysate partitioning in the Genius batch hemodialysis system: effect of temperature and solute concentration.
    Dhondt A, Eloot S, Wachter DD, Smet RD, Waterloos MA, Glorieux G, Lameire N, Verdonck P, Vanholder R.
    Kidney Int; 2005 Jun; 67(6):2470-6. PubMed ID: 15882294
    [Abstract] [Full Text] [Related]

  • 9. Efficiency of the Genius batch hemodialysis system with low serum solute concentrations: the case of lithium intoxication therapy.
    Dhondt A, Verstraete A, Vandewoude K, Segers H, Eloot S, Decruyenaere J, Vanholder R.
    Am J Kidney Dis; 2005 Nov; 46(5):e95-9. PubMed ID: 16253717
    [Abstract] [Full Text] [Related]

  • 10. [How can we improve symptomatic hypotension in hemodialysis patients: cold dialysis vs isothermic dialysis].
    Ramos R, Soto C, Mestres R, Jara J, Zequera H, Merello JI, Moreso F.
    Nefrologia; 2007 Nov; 27(6):737-41. PubMed ID: 18336104
    [Abstract] [Full Text] [Related]

  • 11. Control of core temperature and blood pressure stability during hemodialysis.
    van der Sande FM, Wystrychowski G, Kooman JP, Rosales L, Raimann J, Kotanko P, Carter M, Chan CT, Leunissen KM, Levin NW.
    Clin J Am Soc Nephrol; 2009 Jan; 4(1):93-8. PubMed ID: 18842948
    [Abstract] [Full Text] [Related]

  • 12. Clamping of the dialysate outlet line in the Genius dialysis system does not alter dialysate flow or clearances.
    Van Biesen W, Eloot S, Verleysen A, Glorieux G, Veys N, Vanholder R, Lameire N.
    Nephrol Dial Transplant; 2006 Apr; 21(4):1069-72. PubMed ID: 16410271
    [Abstract] [Full Text] [Related]

  • 13. Stabilizing effects of cool dialysate temperature on hemodynamic parameters in diabetic patients undergoing hemodialysis.
    Ghasemi A, Shafiee M, Rowghani K.
    Saudi J Kidney Dis Transpl; 2008 May; 19(3):378-83. PubMed ID: 18445896
    [Abstract] [Full Text] [Related]

  • 14. Intradialytic changes of serum magnesium and their relation to hypotensive episodes in hemodialysis patients on different dialysates.
    Elsharkawy MM, Youssef AM, Zayoon MY.
    Hemodial Int; 2006 Oct; 10 Suppl 2():S16-23. PubMed ID: 17022745
    [Abstract] [Full Text] [Related]

  • 15. pO2 and pCO2 increment in post-dialyzer blood: the role of dialysate.
    Sombolos KI, Bamichas GI, Christidou FN, Gionanlis LD, Karagianni AC, Anagnostopoulos TC, Natse TA.
    Artif Organs; 2005 Nov; 29(11):892-8. PubMed ID: 16266303
    [Abstract] [Full Text] [Related]

  • 16. Circadian variations in body temperature during dialysis.
    Usvyat LA, Kotanko P, van der Sande FM, Kooman JP, Carter M, Leunissen KM, Levin NW.
    Nephrol Dial Transplant; 2012 Mar; 27(3):1139-44. PubMed ID: 21771757
    [Abstract] [Full Text] [Related]

  • 17. Tumor necrosis factor-alpha during continuous high-flux hemodialysis in sepsis with acute renal failure.
    Lonnemann G, Bechstein M, Linnenweber S, Burg M, Koch KM.
    Kidney Int Suppl; 1999 Nov; (72):S84-7. PubMed ID: 10560813
    [Abstract] [Full Text] [Related]

  • 18. Effect of variations in dialysate temperature on blood pressure during hemodialysis.
    Sherman RA, Faustino EF, Bernholc AS, Eisinger RP.
    Am J Kidney Dis; 1984 Jul; 4(1):66-8. PubMed ID: 6377884
    [Abstract] [Full Text] [Related]

  • 19. Effect of dialysate temperature and diabetes on autonomic cardiovascular regulation during hemodialysis.
    Zitt E, Neyer U, Meusburger E, Tiefenthaler M, Kotanko P, Mayer G, Rosenkranz AR.
    Kidney Blood Press Res; 2008 Jul; 31(4):217-25. PubMed ID: 18587240
    [Abstract] [Full Text] [Related]

  • 20. Vascular reactivity during haemodialysis and isolated ultrafiltration: thermal influences.
    van Kuijk WH, Luik AJ, de Leeuw PW, van Hooff JP, Nieman FH, Habets HM, Leunissen KM.
    Nephrol Dial Transplant; 1995 Oct; 10(10):1852-8. PubMed ID: 8592593
    [Abstract] [Full Text] [Related]


    Page: [Next] [New Search]
    of 10.