These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
327 related items for PubMed ID: 20566953
21. Cost-effectiveness of the Edwards SAPIEN transcatheter heart valve compared with standard management and surgical aortic valve replacement in patients with severe symptomatic aortic stenosis: a Canadian perspective. Doble B, Blackhouse G, Goeree R, Xie F. J Thorac Cardiovasc Surg; 2013 Jul; 146(1):52-60.e3. PubMed ID: 22795437 [Abstract] [Full Text] [Related]
22. Transcatheter valve-in-valve implantation with the Edwards SAPIEN in patients with bioprosthetic heart valve failure: the Milan experience. Latib A, Ielasi A, Montorfano M, Maisano F, Chieffo A, Cioni M, Mussardo M, Bertoldi L, Shannon J, Sacco F, Covello RD, Figini F, Godino C, Grimaldi A, Spagnolo P, Alfieri O, Colombo A. EuroIntervention; 2012 Mar; 7(11):1275-84. PubMed ID: 22278193 [Abstract] [Full Text] [Related]
23. Transfemoral aortic valve implantation with the repositionable Lotus valve compared with the balloon-expandable Edwards Sapien 3 valve. Wöhrle J, Gonska B, Rodewald C, Trepte U, Koch S, Scharnbeck D, Seeger J, Markovic S, Rottbauer W. Int J Cardiol; 2015 Sep 15; 195():171-5. PubMed ID: 26043152 [Abstract] [Full Text] [Related]
24. Transapical transcatheter aortic valve implantation: follow-up to 3 years. Ye J, Cheung A, Lichtenstein SV, Nietlispach F, Albugami S, Masson JB, Thompson CR, Munt B, Moss R, Carere RG, Jamieson WR, Webb JG. J Thorac Cardiovasc Surg; 2010 May 15; 139(5):1107-13, 1113.e1. PubMed ID: 20412948 [Abstract] [Full Text] [Related]
25. Midterm outcomes after transcatheter aortic valve implantation. Lotfi S, Dohmen G, Götzenich A, Haushofer M, Spillner JW, Autschbach R, Hoffmann R. Innovations (Phila); 2014 May 15; 9(5):343-7; discussion 348. PubMed ID: 25238419 [Abstract] [Full Text] [Related]
26. Transaortic transcatheter aortic valve implantation: Results of the Polish arm of the ROUTE registry. Jagielak D, Bramlage P, Pawlaczyk R, Brzeziński M, Fijałkowski M, Łaskawski G, Ciećwierz D, Rogowski J, Kozaryn R. Cardiol J; 2015 May 15; 22(6):651-6. PubMed ID: 26202653 [Abstract] [Full Text] [Related]
27. Outcomes after transfemoral transcatheter aortic valve replacement: a comparison of the randomized PARTNER (Placement of AoRTic TraNscathetER Valves) trial with the NRCA (Nonrandomized Continued Access) registry. Fearon WF, Kodali S, Doshi D, Fischbein MP, Yeung AC, Tuzcu EM, Rihal CS, Babaliaros V, Zajarias A, Herrmann HC, Brown DL, Mack M, Teirstein PS, Whisenant BK, Makkar R, Kapadia S, Leon MB, PARTNER Trial Investigators. JACC Cardiovasc Interv; 2014 Nov 15; 7(11):1245-51. PubMed ID: 25459036 [Abstract] [Full Text] [Related]
28. Series of transcatheter valve-in-valve implantations in high-risk patients with degenerated bioprostheses in aortic and mitral position. Seiffert M, Franzen O, Conradi L, Baldus S, Schirmer J, Meinertz T, Reichenspurner H, Treede H. Catheter Cardiovasc Interv; 2010 Oct 01; 76(4):608-15. PubMed ID: 20506236 [Abstract] [Full Text] [Related]
29. Transcatheter Aortic and Mitral Valve-in-Valve Implantation for Failed Surgical Bioprosthetic Valves: An 8-Year Single-Center Experience. Ye J, Cheung A, Yamashita M, Wood D, Peng D, Gao M, Thompson CR, Munt B, Moss RR, Blanke P, Leipsic J, Dvir D, Webb JG. JACC Cardiovasc Interv; 2015 Nov 01; 8(13):1735-44. PubMed ID: 26476608 [Abstract] [Full Text] [Related]
30. Transcatheter aortic valve replacement for degenerative bioprosthetic surgical valves: results from the global valve-in-valve registry. Dvir D, Webb J, Brecker S, Bleiziffer S, Hildick-Smith D, Colombo A, Descoutures F, Hengstenberg C, Moat NE, Bekeredjian R, Napodano M, Testa L, Lefevre T, Guetta V, Nissen H, Hernández JM, Roy D, Teles RC, Segev A, Dumonteil N, Fiorina C, Gotzmann M, Tchetche D, Abdel-Wahab M, De Marco F, Baumbach A, Laborde JC, Kornowski R. Circulation; 2012 Nov 06; 126(19):2335-44. PubMed ID: 23052028 [Abstract] [Full Text] [Related]
31. Concomitant transapical treatment of aortic stenosis and degenerated mitral bioprosthesis with two 29 mm Edwards Sapien XT prostheses. Misuraca L, Farah B, Tchetche D. J Invasive Cardiol; 2013 Dec 06; 25(12):680-2. PubMed ID: 24296390 [Abstract] [Full Text] [Related]
32. What is the best approach in a patient with a failed aortic bioprosthetic valve: transcatheter aortic valve replacement or redo aortic valve replacement? Tourmousoglou C, Rao V, Lalos S, Dougenis D. Interact Cardiovasc Thorac Surg; 2015 Jun 06; 20(6):837-43. PubMed ID: 25754372 [Abstract] [Full Text] [Related]
33. Registry of transcatheter aortic-valve implantation in high-risk patients. Gilard M, Eltchaninoff H, Iung B, Donzeau-Gouge P, Chevreul K, Fajadet J, Leprince P, Leguerrier A, Lievre M, Prat A, Teiger E, Lefevre T, Himbert D, Tchetche D, Carrié D, Albat B, Cribier A, Rioufol G, Sudre A, Blanchard D, Collet F, Dos Santos P, Meneveau N, Tirouvanziam A, Caussin C, Guyon P, Boschat J, Le Breton H, Collart F, Houel R, Delpine S, Souteyrand G, Favereau X, Ohlmann P, Doisy V, Grollier G, Gommeaux A, Claudel JP, Bourlon F, Bertrand B, Van Belle E, Laskar M, FRANCE 2 Investigators. N Engl J Med; 2012 May 03; 366(18):1705-15. PubMed ID: 22551129 [Abstract] [Full Text] [Related]
34. The impact of live case transmission on patient outcomes during transcatheter aortic valve replacement: results from the VERITAS study. Waksman R, Thomas M, Gloekler S, Sievert H, Webb J, Staiger N, Torguson R, Kaneshige K, Aly M, Colombo A. Cardiovasc Revasc Med; 2014 Mar 03; 15(2):63-8. PubMed ID: 24684756 [Abstract] [Full Text] [Related]
35. Sutureless aortic valve replacement: catheter-based transapical versus direct transaortic implantation. Doss M, Buhr E, Moritz A, Martens S. J Heart Valve Dis; 2012 Nov 03; 21(6):758-63. PubMed ID: 23409358 [Abstract] [Full Text] [Related]
36. European real world trans-catheter aortic valve implantation: systematic review and meta-analysis of European national registries. Krasopoulos G, Falconieri F, Benedetto U, Newton J, Sayeed R, Kharbanda R, Banning A. J Cardiothorac Surg; 2016 Nov 29; 11(1):159. PubMed ID: 27899128 [Abstract] [Full Text] [Related]
38. Transapical aortic valve implantation at 3 years. Walther T, Kempfert J, Rastan A, Borger MA, Linke A, Ender J, Schuler G, Mohr FW. J Thorac Cardiovasc Surg; 2012 Feb 29; 143(2):326-31. PubMed ID: 21724204 [Abstract] [Full Text] [Related]
39. Use of transcatheter heart valves for a valve-in-valve implantation in patients with degenerated aortic bioprosthesis: technical considerations and results. Bapat V, Attia R, Redwood S, Hancock J, Wilson K, Young C, Thomas M. J Thorac Cardiovasc Surg; 2012 Dec 29; 144(6):1372-9; discussion 1379-80. PubMed ID: 23140962 [Abstract] [Full Text] [Related]