These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
100 related items for PubMed ID: 20629698
1. Blood withdrawn through a cannula valve connector does not result in clinically significant haemolysis. Paoloni R, Taghizadeh M, Kouzios D, Janu M. Emerg Med Australas; 2010 Aug; 22(4):310-5. PubMed ID: 20629698 [Abstract] [Full Text] [Related]
2. Randomized, single blinded control trial comparing haemolysis rate between two cannula aspiration techniques. Dwyer DG, Fry M, Somerville A, Holdgate A. Emerg Med Australas; 2006 Aug; 18(5-6):484-8. PubMed ID: 17083638 [Abstract] [Full Text] [Related]
3. Comparison of BD Vacutainer® Rapid Serum Tube and plasma for haemolysis markers in the emergency department. Ryan JB, Stuart LA, Southby SJ, Than MP, Mackay R, Florkowski CM, George PM. Ann Clin Biochem; 2015 Mar; 52(Pt 2):293-6. PubMed ID: 24714681 [Abstract] [Full Text] [Related]
4. Prevention of hemolysis in blood samples collected from intravenous catheters. Lippi G, Avanzini P, Cervellin G. Clin Biochem; 2013 May; 46(7-8):561-4. PubMed ID: 23391635 [Abstract] [Full Text] [Related]
5. Studies on the use of BD Vacutainer® SST II™ and RST™ in general practice: investigation of artefactual hyperkalaemia. Huyghe T, Buntinx F, Bruyninckx R, Besard V, Vunckx J, Church S, Byron K, Rosa R, Blanckaert N. Ann Clin Biochem; 2014 Jan; 51(Pt 1):30-7. PubMed ID: 23897107 [Abstract] [Full Text] [Related]
6. Apparent hyperkalaemia from blood sampled from an arterial cannula. Mehta V, Ahmed Z. Br J Anaesth; 2004 Sep; 93(3):456-8. PubMed ID: 15194630 [Abstract] [Full Text] [Related]
7. The impact of blood sampling technique, including the use of peripheral intravenous cannula, on haemolysis rates: A cohort study. Jacob E, Jacob A, Davies H, Jacob D, Jenkins M, Husain M, Coventry L. J Clin Nurs; 2021 Jul; 30(13-14):1916-1926. PubMed ID: 33829557 [Abstract] [Full Text] [Related]
8. [A comparison of the rates of hemolysis and repeated blood sampling using syringe needles versus vacuum tube needles in the emergency department]. Sung YH, Hwang MS, Lee JH, Park HD, Ryu KH, Cho MS, Yi YH, Song S. J Korean Acad Nurs; 2012 Jun; 42(3):443-51. PubMed ID: 22854557 [Abstract] [Full Text] [Related]
9. A prospective study of causes of haemolysis during venepuncture: tourniquet time should be kept to a minimum. Saleem S, Mani V, Chadwick MA, Creanor S, Ayling RM. Ann Clin Biochem; 2009 May; 46(Pt 3):244-6. PubMed ID: 19389888 [Abstract] [Full Text] [Related]
10. Detection of haemolysis and reporting of potassium results in samples from neonates. Jeffery J, Sharma A, Ayling RM. Ann Clin Biochem; 2009 May; 46(Pt 3):222-5. PubMed ID: 19261676 [Abstract] [Full Text] [Related]
11. Pneumatic tube system induced haemolysis: assessing sample type susceptibility to haemolysis. Sodi R, Darn SM, Stott A. Ann Clin Biochem; 2004 May; 41(Pt 3):237-40. PubMed ID: 15117440 [Abstract] [Full Text] [Related]
12. Haemolyzed samples: responsibility of short catheters. Raisky F, Gauthier C, Marchal A, Blum D. Ann Biol Clin (Paris); 1994 May; 52(7-8):523-7. PubMed ID: 7840428 [Abstract] [Full Text] [Related]
13. Testing the effects of educational toilet posters: a novel way of reducing haemolysis of blood samples within ED. Corkill D. Australas Emerg Nurs J; 2012 Feb; 15(1):31-6. PubMed ID: 22813621 [Abstract] [Full Text] [Related]
14. Factors affecting blood sample haemolysis: a cross-sectional study. Barnard EB, Potter DL, Ayling RM, Higginson I, Bailey AG, Smith JE. Eur J Emerg Med; 2016 Apr; 23(2):143-6. PubMed ID: 25093898 [Abstract] [Full Text] [Related]
15. Serum S100B levels in patients after cardiac surgery: possible sources of contamination. Babin-Ebell J, Roth P, Reese J, Bechtel M, Mortasawi A. Thorac Cardiovasc Surg; 2007 Apr; 55(3):168-72. PubMed ID: 17410502 [Abstract] [Full Text] [Related]
16. [Can a blood sample for diagnostic exams be drawn from a peripheral venous catheter?]. Benso S. Assist Inferm Ric; 2015 Apr; 34(2):86-92. PubMed ID: 26228505 [Abstract] [Full Text] [Related]
17. The effect of the InterLink cannula on fluid flow rates and haemolysis. Saw S, Arendts G. Emerg Med (Fremantle); 2001 Dec; 13(4):456-9. PubMed ID: 11903431 [Abstract] [Full Text] [Related]
18. Blood trauma in plastic haemodialysis cannulae. De Wachter DS, Verdonck PR, De Vos JY, Hombrouckx RO. Int J Artif Organs; 1997 Jul; 20(7):366-70. PubMed ID: 9298407 [Abstract] [Full Text] [Related]
19. A paradigmatic case of haemolysis and pseudohyperkalemia in blood gas analysis. Salvagno GL, Demonte D, Lippi G. Biochem Med (Zagreb); 2019 Feb 15; 29(1):011003. PubMed ID: 30799980 [Abstract] [Full Text] [Related]
20. Reducing blood sample hemolysis at a tertiary hospital emergency department. Ong ME, Chan YH, Lim CS. Am J Med; 2009 Nov 15; 122(11):1054.e1-6. PubMed ID: 19854334 [Abstract] [Full Text] [Related] Page: [Next] [New Search]