These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
138 related items for PubMed ID: 20689918
1. Comparison of cardiac output and blood volumes in intrathoracic compartments measured by ultrasound dilution and transpulmonary thermodilution methods. Galstyan G, Bychinin M, Alexanyan M, Gorodetsky V. Intensive Care Med; 2010 Dec; 36(12):2140-4. PubMed ID: 20689918 [Abstract] [Full Text] [Related]
6. Comparison of cardiac function index derived from femoral and jugular indicator injection for transpulmonary thermodilution with the PiCCO-device: A prospective observational study. Herner A, Heilmaier M, Mayr U, Schmid RM, Huber W. PLoS One; 2018 Jul; 13(7):e0200740. PubMed ID: 30063736 [Abstract] [Full Text] [Related]
8. Comparison of a new cardiac output ultrasound dilution method with thermodilution technique in adult patients under general anesthesia. Tsutsui M, Matsuoka N, Ikeda T, Sanjo Y, Kazama T. J Cardiothorac Vasc Anesth; 2009 Dec; 23(6):835-40. PubMed ID: 19464193 [Abstract] [Full Text] [Related]
9. Assessment of cardiac preload and extravascular lung water by single transpulmonary thermodilution. Sakka SG, Rühl CC, Pfeiffer UJ, Beale R, McLuckie A, Reinhart K, Meier-Hellmann A. Intensive Care Med; 2000 Feb; 26(2):180-7. PubMed ID: 10784306 [Abstract] [Full Text] [Related]
14. Assessment of intrathoracic blood volume as an indicator of cardiac preload: single transpulmonary thermodilution technique versus assessment of pressure preload parameters derived from a pulmonary artery catheter. Wiesenack C, Prasser C, Keyl C, Rödīg G. J Cardiothorac Vasc Anesth; 2001 Oct; 15(5):584-8. PubMed ID: 11687999 [Abstract] [Full Text] [Related]
15. Validation of a new transpulmonary thermodilution system to assess global end-diastolic volume and extravascular lung water. Bendjelid K, Giraud R, Siegenthaler N, Michard F. Crit Care; 2010 Oct; 14(6):R209. PubMed ID: 21092252 [Abstract] [Full Text] [Related]
18. Three-dimensional transoesophageal echocardiography for cardiac output in critically ill patients: A pilot study of ultrasound versus the thermodilution method. Hammoudi N, Hékimian G, Laveau F, Achkar M, Isnard R, Combes A. Arch Cardiovasc Dis; 2017 Jan; 110(1):7-13. PubMed ID: 28017278 [Abstract] [Full Text] [Related]
20. Comparison of global end-diastolic volume index derived from jugular and femoral indicator injection: a prospective observational study in patients equipped with both a PiCCO-2 and an EV-1000-device. Herner A, Heilmaier M, Mayr U, Schmid RM, Huber W. Sci Rep; 2020 Nov 27; 10(1):20773. PubMed ID: 33247165 [Abstract] [Full Text] [Related] Page: [Next] [New Search]