These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
2. Clinical monitoring of cardiac output assessed by transoesophageal echocardiography in anaesthetised dogs: a comparison with the thermodilution technique. Mantovani MM, Fantoni DT, Gimenes AM, de Castro JR, Flor PB, Ida KK, Schwartz DS. BMC Vet Res; 2017 Nov 09; 13(1):325. PubMed ID: 29121915 [Abstract] [Full Text] [Related]
5. Comparison of thermodilution, lithium dilution, and pulse contour analysis for the measurement of cardiac output in 3 different hemodynamic states in dogs. Morgaz J, Granados Mdel M, Muñoz-Rascón P, Dominguez JM, Fernández-Sarmiento JA, Gómez-Villamandos RJ, Navarrete R. J Vet Emerg Crit Care (San Antonio); 2014 Nov 09; 24(5):562-70. PubMed ID: 25142925 [Abstract] [Full Text] [Related]
6. Evaluation of an oesophageal Doppler device for monitoring cardiac output in anaesthetised healthy normotensive dogs. Canfrán S, Cediel R, Sández I, Caro-Vadillo A, Gómez de Segura IA. J Small Anim Pract; 2015 Jul 09; 56(7):450-5. PubMed ID: 25913545 [Abstract] [Full Text] [Related]
7. Evaluation of agreement and trending ability between transpulmonary thermodilution and calibrated pulse contour and pulse power cardiac output monitoring methods against pulmonary artery thermodilution in anesthetized dogs. Kutter AP, Bettschart-Wolfensberger R, Romagnoli N, Bektas RN. J Vet Emerg Crit Care (San Antonio); 2016 Jul 09; 26(4):531-40. PubMed ID: 26754858 [Abstract] [Full Text] [Related]
8. Comparison of cardiac output measurements using transpulmonary thermodilution and conventional thermodilution techniques in anaesthetized dogs with fluid overload. Itami T, Endo Y, Hanazono K, Ishizuka T, Tamura J, Miyoshi K, Sano T, Yamashita K. Vet Anaesth Analg; 2016 Jul 09; 43(4):388-96. PubMed ID: 26671761 [Abstract] [Full Text] [Related]
9. Noninvasive cardiac output monitoring by aortic blood flow determination: evaluation of the Sometec Dynemo-3000 system. Cariou A, Monchi M, Joly LM, Bellenfant F, Claessens YE, Thébert D, Brunet F, Dhainaut JF. Crit Care Med; 1998 Dec 09; 26(12):2066-72. PubMed ID: 9875922 [Abstract] [Full Text] [Related]
10. Comparison of cardiac output measured by intrapulmonary artery Doppler, thermodilution, and electromagnetometry. Heerdt PM, Pond CG, Blessios GA, Rosenbloom M. Ann Thorac Surg; 1992 Nov 09; 54(5):959-66. PubMed ID: 1417293 [Abstract] [Full Text] [Related]
12. Evaluation of transesophageal echo-Doppler ultrasonography for the measurement of aortic blood flow in anesthetized cats. Rezende ML, Pypendop BH, Ilkiw JE. Am J Vet Res; 2008 Sep 09; 69(9):1135-40. PubMed ID: 18764683 [Abstract] [Full Text] [Related]
13. Agreement of cardiac output measurements by esophageal Doppler and transesophageal echocardiography with intermittent pulmonary artery thermodilution during pharmacologic manipulation of hemodynamics in anesthetized dogs. Paranjape VV, Pereira FLG, Menciotti G, Saksena S, Guerrero NH, Pereira CHR. Am J Vet Res; 2023 Aug 01; 84(8):. PubMed ID: 37385599 [Abstract] [Full Text] [Related]
14. Comparison of pulmonary artery and transpulmonary thermodilution cardiac output measurements in unsedated newborn calves. Kutter AP, Jud Schefer RS, Bircher B, Bleul U, Bettschart-Wolfensberger R. Vet Anaesth Analg; 2015 Nov 01; 42(6):614-22. PubMed ID: 25689575 [Abstract] [Full Text] [Related]
15. Measurements of cardiac output obtained with transesophageal echocardiography and pulmonary artery thermodilution are not interchangeable. Møller-Sørensen H, Graeser K, Hansen KL, Zemtsovski M, Sander EM, Nilsson JC. Acta Anaesthesiol Scand; 2014 Jan 01; 58(1):80-8. PubMed ID: 24192143 [Abstract] [Full Text] [Related]
16. Doppler cardiac output and left ventricular performance after cardiac surgery. Pulsed Doppler ascending aorta and pulmonary blood flows and left ventricular function using implanted microprobes. Fratacci MD, Payen D, Beloucif S, Laborde F. Chest; 1992 Aug 01; 102(2):380-6. PubMed ID: 1643918 [Abstract] [Full Text] [Related]
18. [Comparison between two methods for hemodynamic measurement: thermodilution and oesophageal doppler]. Ferreira RM, do Amaral JL, Valiatti JL. Rev Assoc Med Bras (1992); 2007 Aug 01; 53(4):349-54. PubMed ID: 17823740 [Abstract] [Full Text] [Related]
19. Bispectral index in dogs at three intravenous infusion rates of propofol. Lopes PC, Nunes N, Paula DP, Nishimori CT, Guerrero PN, Conceição ED. Vet Anaesth Analg; 2008 May 01; 35(3):228-31. PubMed ID: 18282255 [Abstract] [Full Text] [Related]
20. Comparison of methods of cardiac output measurements determined by dye dilution, pulsed Doppler echocardiography and thermodilution in horses. Mizuno Y, Aida H, Hara H, Fujinaga T, Hagio M. J Vet Med Sci; 1994 Feb 01; 56(1):1-5. PubMed ID: 8204732 [Abstract] [Full Text] [Related] Page: [Next] [New Search]