These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
22. [Continuous Svo2 measurements and co-oximetry are not interchangeable immediately after cardiopulmonary bypass]. Bendjelid K, Schutz N, Suter PM, Romand JA. Can J Anaesth; 2004 Dec; 51(6):610-5. PubMed ID: 15197124 [Abstract] [Full Text] [Related]
23. [Comparison of 2 systems for continuous intraoperative monitoring of oxygen saturation in the jugular bulb]. García del Valle S, Bartolomé A, Menéndez B, Azofra J, Requejo MD. Rev Esp Anestesiol Reanim; 1996 Feb; 43(2):49-52. PubMed ID: 8869648 [Abstract] [Full Text] [Related]
24. Central venous oxygen saturation for the diagnosis of low cardiac output in septic shock patients. Perner A, Haase N, Wiis J, White JO, Delaney A. Acta Anaesthesiol Scand; 2010 Jan; 54(1):98-102. PubMed ID: 19735495 [Abstract] [Full Text] [Related]
25. Evaluation of a new combined transcutaneous measurement of PCO2/pulse oximetry oxygen saturation ear sensor in newborn patients. Bernet-Buettiker V, Ugarte MJ, Frey B, Hug MI, Baenziger O, Weiss M. Pediatrics; 2005 Jan; 115(1):e64-8. PubMed ID: 15601814 [Abstract] [Full Text] [Related]
26. [Intra-arterial catheter oximetry and pulse oximetry in comparison with CO-oximetry in heart surgery]. Haessler R, Brandl F, Zeller M, Briegel J, Finsterer U. Anaesthesist; 1991 Nov; 40(11):602-7. PubMed ID: 1755530 [Abstract] [Full Text] [Related]
27. Alteplase for the treatment of central venous catheter occlusion in children: results of a prospective, open-label, single-arm study (The Cathflo Activase Pediatric Study). Blaney M, Shen V, Kerner JA, Jacobs BR, Gray S, Armfield J, Semba CP, CAPS Investigators. J Vasc Interv Radiol; 2006 Nov; 17(11 Pt 1):1745-51. PubMed ID: 17142704 [Abstract] [Full Text] [Related]
28. [The accuracy of 4 different oximeters for continuous monitoring of mixed venous oxygen saturation during abdominal aortic surgery]. Zaune U, Spies C, Pauli MH, Boeden G, Martin E. Anaesthesist; 1992 Feb; 41(2):71-5. PubMed ID: 1562095 [Abstract] [Full Text] [Related]
29. [Assessment of diagnostic methods for the catheter-related bloodstream infections in intensive care units]. Ataman Hatipoğlu C, Ipekkan K, Oral B, Onde U, Bulut C, Demiröz AP. Mikrobiyol Bul; 2011 Jan; 45(1):75-85. PubMed ID: 21341162 [Abstract] [Full Text] [Related]
30. Reduction of catheter-associated bloodstream infections in pediatric patients: experimentation and reality. McKee C, Berkowitz I, Cosgrove SE, Bradley K, Beers C, Perl TM, Winner L, Pronovost PJ, Miller MR. Pediatr Crit Care Med; 2008 Jan; 9(1):40-6. PubMed ID: 18477912 [Abstract] [Full Text] [Related]
31. Comparison of traditional and plethysmographic methods for measuring pulsus paradoxus. Clark JA, Lieh-Lai M, Thomas R, Raghavan K, Sarnaik AP. Arch Pediatr Adolesc Med; 2004 Jan; 158(1):48-51. PubMed ID: 14706958 [Abstract] [Full Text] [Related]
32. [Use of peripherally inserted multilumen catheters as an alternative to central venous access]. Pardo De La Vega R, Los Arcos Solas M, Ferrero De La Mano L, Medina Villanueva A, Concha Torre A, Rey Galán C. An Esp Pediatr; 2002 Jul; 57(1):18-21. PubMed ID: 12139888 [Abstract] [Full Text] [Related]
33. Continuous monitoring of central venous oxygen saturation in neonates and small infants: in vitro evaluation of two different oximetry catheters. Huber D, Osthaus WA, Optenhöfel J, Breymann T, Marx G, Piepenbrock S, Sümpelmann R. Paediatr Anaesth; 2006 Dec; 16(12):1257-61. PubMed ID: 17121556 [Abstract] [Full Text] [Related]
34. Continuous cardiac index monitoring: A prospective observational study of agreement between a pulmonary artery catheter and a calibrated minimally invasive technique. McCoy JV, Hollenberg SM, Dellinger RP, Arnold RC, Ruoss L, Lotano V, Peters P, Parrillo JE, Trzeciak S. Resuscitation; 2009 Aug; 80(8):893-7. PubMed ID: 19520480 [Abstract] [Full Text] [Related]
36. Comparison of central venous to mixed venous oxygen saturation in patients with low cardiac index and filling pressures after coronary artery surgery. Yazigi A, El Khoury C, Jebara S, Haddad F, Hayeck G, Sleilaty G. J Cardiothorac Vasc Anesth; 2008 Feb; 22(1):77-83. PubMed ID: 18249335 [Abstract] [Full Text] [Related]
37. Pulse oximeter accuracy and precision affected by sensor location in cyanotic children. Sedaghat-Yazdi F, Torres A, Fortuna R, Geiss DM. Pediatr Crit Care Med; 2008 Jul; 9(4):393-7. PubMed ID: 18496398 [Abstract] [Full Text] [Related]
38. Comparison of SpO2 to PaO2 based markers of lung disease severity for children with acute lung injury. Khemani RG, Thomas NJ, Venkatachalam V, Scimeme JP, Berutti T, Schneider JB, Ross PA, Willson DF, Hall MW, Newth CJ, Pediatric Acute Lung Injury and Sepsis Network Investigators (PALISI). Crit Care Med; 2012 Apr; 40(4):1309-16. PubMed ID: 22202709 [Abstract] [Full Text] [Related]
39. Mixed venous oxygen saturation during mobilization after cardiac surgery: are reflectance oximetry catheters reliable? Kirkeby-Garstad I, Skogvoll E, Sellevold FM. Acta Anaesthesiol Scand; 2000 Oct; 44(9):1103-8. PubMed ID: 11028731 [Abstract] [Full Text] [Related]
40. Prolonged central venous desaturation measured by continuous oximetry is associated with adverse outcomes in pediatric cardiac surgery. Crowley R, Sanchez E, Ho JK, Lee KJ, Schwarzenberger J, Marijic J, Sopher M, Mahajan A. Anesthesiology; 2011 Nov; 115(5):1033-43. PubMed ID: 21952253 [Abstract] [Full Text] [Related] Page: [Previous] [Next] [New Search]