These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
2. The effects of dose and radiation quality on the shape and power saturation of the EPR signal in alanine. Ciesielski B, Wielopolski L. Radiat Res; 1994 Oct; 140(1):105-11. PubMed ID: 7938443 [Abstract] [Full Text] [Related]
4. Combined effects of high doses and temperature on radiation-induced radicals and their relative contributions to EPR signal in gamma-irradiated alanine. Ciesielski B. Radiat Prot Dosimetry; 2006 Oct; 120(1-4):184-90. PubMed ID: 16565208 [Abstract] [Full Text] [Related]
6. Comments on "The effects of dose and radiation quality on the shape and power saturation of the EPR signal in alanine" (Radiat. Res. 140, 105-111, 1994). Simmons JA. Radiat Res; 1995 Jul; 143(1):113-5. PubMed ID: 7597138 [No Abstract] [Full Text] [Related]
7. Uncertainties in alanine/ESR dosimetry at the Physikalisch-Technische Bundesanstalt. Anton M. Phys Med Biol; 2006 Nov 07; 51(21):5419-40. PubMed ID: 17047261 [Abstract] [Full Text] [Related]
8. Use of the entire spectrum of irradiated alanine for dosimetry. Dolo JM, Moignau F. Appl Radiat Isot; 2005 Feb 07; 62(2):281-5. PubMed ID: 15607462 [Abstract] [Full Text] [Related]
9. EPR dosimetry of radiotherapy photon beams in inhomogeneous media using alanine films. Osterås BH, Hole EO, Olsen DR, Malinen E. Phys Med Biol; 2006 Dec 21; 51(24):6315-28. PubMed ID: 17148820 [Abstract] [Full Text] [Related]
11. Response of the alanine/ESR dosimetry system to MV X-rays relative to (60)Co radiation. Anton M, Kapsch RP, Krystek M, Renner F. Phys Med Biol; 2008 May 21; 53(10):2753-70. PubMed ID: 18448875 [Abstract] [Full Text] [Related]
12. EPR study of light illumination effects on radicals in gamma-irradiated L-alanine. Ciesielski B, Schultka K, Penkowski M, Sagstuen E. Spectrochim Acta A Mol Biomol Spectrosc; 2004 May 21; 60(6):1327-33. PubMed ID: 15134731 [Abstract] [Full Text] [Related]
13. Use of commercial alanine and TL dosemeters for dosimetry intercomparisons among Italian radiotherapy centres. Onori S, Bortolin E, Calicchia A, Carosi A, De Angelis C, Grande S. Radiat Prot Dosimetry; 2006 May 21; 120(1-4):226-9. PubMed ID: 16644956 [Abstract] [Full Text] [Related]
14. Use of alanine for dosimetry intercomparisons among Italian radiotherapy centers. De Angelis C, De Coste V, Fattibene P, Onori S, Petetti E. Appl Radiat Isot; 2005 Feb 21; 62(2):261-5. PubMed ID: 15607459 [Abstract] [Full Text] [Related]
15. Effect of temperature on the electron paramagnetic resonance spectrum of irradiated alanine. Vanhaelewyn GC, Mondelaers WK, Callens FJ. Radiat Res; 1999 May 21; 151(5):590-4. PubMed ID: 10319732 [Abstract] [Full Text] [Related]
17. Development of physical and numerical techniques of Alanine/EPR dosimetry in radiotherapy. Castro F, Ponte F, Pereira L. Radiat Prot Dosimetry; 2006 May 21; 122(1-4):509-12. PubMed ID: 17166873 [Abstract] [Full Text] [Related]
18. An experimental and Monte Carlo investigation of the energy dependence of alanine/EPR dosimetry: II. Clinical electron beams. Zeng GG, McEwen MR, Rogers DW, Klassen NV. Phys Med Biol; 2005 Mar 21; 50(6):1119-29. PubMed ID: 15798312 [Abstract] [Full Text] [Related]
20. Analyses of the EPR responses of sucrose and L-alpha-alanine radicals induced by C, Ne, and Ar ion irradiations. Nakagawa K, Sato Y. Spectrochim Acta A Mol Biomol Spectrosc; 2006 Mar 13; 63(4):851-4. PubMed ID: 16490388 [Abstract] [Full Text] [Related] Page: [Next] [New Search]