These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
3. Preservation of in vitro function of platelets stored in the presence of a synthetic dual inhibitor of factor Xa and thrombin. Hellstern P, Stürzebecher U, Wuchold B, Haubelt H, Seyfert UT, Bauer M, Vogt A, Stürzebecher J. J Thromb Haemost; 2007 Oct; 5(10):2119-26. PubMed ID: 17666019 [Abstract] [Full Text] [Related]
4. Which is the best anticoagulant for whole blood aggregometry platelet function testing? Comparison of six anticoagulants and diverse storage conditions. Kaiser AF, Neubauer H, Franken CC, Krüger JC, Mügge A, Meves SH. Platelets; 2012 Oct; 23(5):359-67. PubMed ID: 21999185 [Abstract] [Full Text] [Related]
8. Multiple electrode aggregometry: a new device to measure platelet aggregation in whole blood. Tóth O, Calatzis A, Penz S, Losonczy H, Siess W. Thromb Haemost; 2006 Dec; 96(6):781-8. PubMed ID: 17139373 [Abstract] [Full Text] [Related]
10. Comparison of Commercially Available Blood Collection Tubes Containing Sodium Citrate and Hirudin in Platelet Aggregation Testing. Janse van Rensburg WJ, van der Merwe P. Med Sci Monit Basic Res; 2017 Jul 27; 23():264-269. PubMed ID: 28747619 [Abstract] [Full Text] [Related]
11. Doubling the clopidogrel dose in patients with reduced responsiveness to the standard dose is associated with a limited effectiveness as evaluated by impedance aggregometry. Stellbaum C, Ayral Y, Morguet A, Schultheiss HP, Rauch U. Cardiovasc Revasc Med; 2012 Jul 27; 13(3):159-66. PubMed ID: 22503564 [Abstract] [Full Text] [Related]
12. Measurement of platelet aggregation in ovine blood using a new impedance aggregometer. Baumgarten A, Wilhelmi M, Kalbantner K, Ganter M, Mischke R. Vet Clin Pathol; 2010 Jun 27; 39(2):149-56. PubMed ID: 20003029 [Abstract] [Full Text] [Related]
16. The effect of ex vivo anticoagulants on whole blood platelet aggregation. Kalb ML, Potura L, Scharbert G, Kozek-Langenecker SA. Platelets; 2009 Feb 27; 20(1):7-11. PubMed ID: 19172515 [Abstract] [Full Text] [Related]
17. Whole blood platelet aggregation determined by the ROTEM platelet equipment; reference intervals and stability. Nissen PH, Skipper MT, Hvas AM. Platelets; 2020 Feb 27; 31(2):215-220. PubMed ID: 30935283 [Abstract] [Full Text] [Related]
18. Reference range determination for whole-blood platelet aggregation using the Multiplate analyzer. Peerschke EI, Castellone DD, Stroobants AK, Francis J. Am J Clin Pathol; 2014 Nov 27; 142(5):647-56. PubMed ID: 25319980 [Abstract] [Full Text] [Related]