These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


170 related items for PubMed ID: 21175972

  • 21. Predicting episodes of hypotension by continuous blood volume monitoring among critically ill patients in acute renal failure on intermittent hemodialysis.
    Tanguay TA, Jensen L, Johnston C.
    Dynamics; 2007; 18(3):19-24. PubMed ID: 17879763
    [Abstract] [Full Text] [Related]

  • 22. Measurement of relative blood volume changes during haemodialysis: merits and limitations.
    Dasselaar JJ, Huisman RM, de Jong PE, Franssen CF.
    Nephrol Dial Transplant; 2005 Oct; 20(10):2043-9. PubMed ID: 16105867
    [No Abstract] [Full Text] [Related]

  • 23. Absolute blood volume in hemodialysis patients: why is it relevant, and how to measure it?
    Thijssen S, Kappel F, Kotanko P.
    Blood Purif; 2013 Oct; 35(1-3):63-71. PubMed ID: 23343548
    [Abstract] [Full Text] [Related]

  • 24. [Effect of the temperature of the dialysis bath in diabetics].
    Galli CN, López M, Beresan H, Elbert A.
    Medicina (B Aires); 2004 Oct; 64(6):487-91. PubMed ID: 15637824
    [Abstract] [Full Text] [Related]

  • 25. Recent advances in the monitoring and control of haemodynamic variables during haemodialysis: a review.
    Javed F, Savkin AV, Chan GS, Mackie JD, Lovell NH.
    Physiol Meas; 2012 Jan; 33(1):R1-R31. PubMed ID: 22155986
    [Abstract] [Full Text] [Related]

  • 26. Ultrafiltration biofeedback guided by blood volume monitoring to reduce intradialytic hypotensive episodes in hemodialysis: study protocol for a randomized controlled trial.
    Leung KC, Quinn RR, Ravani P, MacRae JM.
    Trials; 2014 Dec 10; 15():483. PubMed ID: 25496294
    [Abstract] [Full Text] [Related]

  • 27. Preventing haemodynamic instability in patients at risk for intra-dialytic hypotension.
    Leunissen KM, Kooman JP, van Kuijk W, van der Sande F, Luik AJ, van Hooff JP.
    Nephrol Dial Transplant; 1996 Dec 10; 11 Suppl 2():11-5. PubMed ID: 8803987
    [Abstract] [Full Text] [Related]

  • 28. The dialysis staff workload and the blood volume tracking system during the hemodialysis sessions of hypotension-prone patients.
    Doria M, Genovesi S, Biagi F, Steckiph D, Mancini E, Stella A, Santoro A.
    Int J Artif Organs; 2014 Apr 10; 37(4):292-8. PubMed ID: 24811183
    [Abstract] [Full Text] [Related]

  • 29. Ultrafiltration profiling and measurement of relative blood volume as strategies to reduce hemodialysis-related side effects.
    Donauer J, Kölblin D, Bek M, Krause A, Böhler J.
    Am J Kidney Dis; 2000 Jul 10; 36(1):115-23. PubMed ID: 10873880
    [Abstract] [Full Text] [Related]

  • 30. Can advances in hemodialysis machine technology prevent intradialytic hypotension?
    Davenport A.
    Semin Dial; 2009 Jul 10; 22(3):231-6. PubMed ID: 19572996
    [Abstract] [Full Text] [Related]

  • 31. Oral intake during hemodialysis: is there an association with intradialytic hypotension?
    Benaroia M, Iliescu EA.
    Hemodial Int; 2008 Jan 10; 12(1):62-5. PubMed ID: 18271843
    [Abstract] [Full Text] [Related]

  • 32. Novel Insights into the Pathogenesis and Prevention of Intradialytic Hypotension.
    van der Sande FM, Dekker MJ, Leunissen KML, Kooman JP.
    Blood Purif; 2018 Jan 10; 45(1-3):230-235. PubMed ID: 29478062
    [Abstract] [Full Text] [Related]

  • 33. Impact of sodium and ultrafiltration profiling on haemodialysis-related hypotension.
    Zhou YL, Liu HL, Duan XF, Yao Y, Sun Y, Liu Q.
    Nephrol Dial Transplant; 2006 Nov 10; 21(11):3231-7. PubMed ID: 16954178
    [Abstract] [Full Text] [Related]

  • 34. The effect of changes in intra-compartmental bioimpedance measurements with early intra-dialytic hypotension during haemodialysis.
    Haroon S, Davenport A.
    Int J Artif Organs; 2024 Nov 10; 47(11):802-809. PubMed ID: 39166424
    [Abstract] [Full Text] [Related]

  • 35. Simultaneous blood temperature control and blood volume control reduces intradialytic symptoms.
    Veljančic L, Popović J, Radović M, Ahrenholz P, Ries W, Frenken L, Wojke R.
    Int J Artif Organs; 2011 Apr 10; 34(4):357-64. PubMed ID: 21534246
    [Abstract] [Full Text] [Related]

  • 36. [Thermal energy balance during hemodialysis: the role of the filter membrane].
    Panzetta G, Bianco F, Galli G, Ianche M, Savoldi S, Vianello S, Vidi E, Cicinato P.
    G Ital Nefrol; 2002 Apr 10; 19(4):425-31. PubMed ID: 12369045
    [Abstract] [Full Text] [Related]

  • 37. Effects of ivabradine on the prevention of intradialytic hypotension in a dialytic patient with heart failure with reduced ejection fraction.
    Nakano Y, Ando H, Suzuki W, Amano T.
    BMJ Case Rep; 2021 Nov 30; 14(11):. PubMed ID: 34848415
    [Abstract] [Full Text] [Related]

  • 38. Haemodialysis decreases finger pressures independent of artificial kidney blood flow.
    Van Hoek F, Scheltinga MR, Houterman S, Beerenhout CH.
    Nephrology (Carlton); 2010 Aug 30; 15(5):555-9. PubMed ID: 20649876
    [Abstract] [Full Text] [Related]

  • 39. Characteristics of hypotension-prone haemodialysis patients: is there a critical relative blood volume?
    Franssen C, Dasselaar J, Huisman R.
    Nephrol Dial Transplant; 2004 Apr 30; 19(4):1010-1; author reply 1011-2. PubMed ID: 15031370
    [No Abstract] [Full Text] [Related]

  • 40. Midodrine is effective and safe therapy for intradialytic hypotension over 8 months of follow-up.
    Cruz DN, Mahnensmith RL, Brickel HM, Perazella MA.
    Clin Nephrol; 1998 Aug 30; 50(2):101-7. PubMed ID: 9725781
    [Abstract] [Full Text] [Related]


    Page: [Previous] [Next] [New Search]
    of 9.