1. Reduction of radiation doses to patients and staff during endoscopic retrograde cholangiopancreatography. Sulieman A, Paroutoglou G, Kapsoritakis A, Kapatenakis A, Potamianos S, Vlychou M, Theodorou K. Saudi J Gastroenterol; 2011; 17(1):23-9. PubMed ID: 21196649 [Abstract] [Full Text] [Related]
2. Patient and staff exposure during endoscopic retrograde cholangiopancreatography. Buls N, Pages J, Mana F, Osteaux M. Br J Radiol; 2002 May; 75(893):435-43. PubMed ID: 12036837 [Abstract] [Full Text] [Related]
3. Occupational exposure to staff during endoscopic retrograde cholangiopancreatography in Sudan. Sulieman A, Elzaki M, Khalil M. Radiat Prot Dosimetry; 2011 Mar; 144(1-4):530-3. PubMed ID: 21062799 [Abstract] [Full Text] [Related]
4. Radiation dose optimisation and risk estimation to patients and staff during hysterosalpingography. Sulieman A, Theodorou K, Vlychou M, Topaltzikis T, Roundas C, Fezoulidis I, Kappas C. Radiat Prot Dosimetry; 2008 Mar; 128(2):217-26. PubMed ID: 17584732 [Abstract] [Full Text] [Related]
5. Occupational radiation dose to eyes from endoscopic retrograde cholangiopancreatography procedures in light of the revised eye lens dose limit from the International Commission on Radiological Protection. O'Connor U, Gallagher A, Malone L, O'Reilly G. Br J Radiol; 2013 Feb; 86(1022):20120289. PubMed ID: 23385992 [Abstract] [Full Text] [Related]
6. Evaluation of radiation doses in patient and medical staff during endoscopic retrograde cholangiopancreatography procedures. Seo D, Kim KH, Kim JS, Han S, Park K, Kim J. Radiat Prot Dosimetry; 2016 Mar; 168(4):516-22. PubMed ID: 26269518 [Abstract] [Full Text] [Related]
7. Evaluation of staff, patient and foetal radiation doses due to endoscopic retrograde cholangiopancreatography (ERCP) procedures in a pregnant patient. Huda A, Garzón WJ, Filho GC, Vieira B, Kramer R, Xu XG, Gao Y, Khoury HJ. Radiat Prot Dosimetry; 2016 Mar; 168(3):401-7. PubMed ID: 26084305 [Abstract] [Full Text] [Related]
8. Measurement of Hp(10), Hp(3) and Hp(0.07) to medical staff in endoscopic retrograde cholangiopancreatography, using thermoluminescence dosimetry. ZarifSanayei A, Sina S. Radiat Prot Dosimetry; 2024 Apr 04; 200(5):473-480. PubMed ID: 38324516 [Abstract] [Full Text] [Related]
9. Patient and staff doses for some complex x-ray examinations. Olgar T, Bor D, Berkmen G, Yazar T. J Radiol Prot; 2009 Sep 04; 29(3):393-407. PubMed ID: 19690354 [Abstract] [Full Text] [Related]
10. The radiation doses and radiation protection on the endoscopic retrograde cholangiopancreatography procedures. Takenaka M, Hosono M, Hayashi S, Nishida T, Kudo M. Br J Radiol; 2021 Oct 01; 94(1126):20210399. PubMed ID: 34379457 [Abstract] [Full Text] [Related]
11. Evaluation of patient and staff doses during various CT fluoroscopy guided interventions. Buls N, Pagés J, de Mey J, Osteaux M. Health Phys; 2003 Aug 01; 85(2):165-73. PubMed ID: 12938963 [Abstract] [Full Text] [Related]
12. Optimisation of Radiation Exposure to Gastroenterologists and Patients during Therapeutic ERCP. Alzimami K, Sulieman A, Paroutoglou G, Potamianos S, Vlychou M, Theodorou K. Gastroenterol Res Pract; 2013 Aug 01; 2013():587574. PubMed ID: 23589714 [Abstract] [Full Text] [Related]
13. Radiation exposure to personnel performing endoscopic retrograde cholangiopancreatography. Naidu LS, Singhal S, Preece DE, Vohrah A, Loft DE. Postgrad Med J; 2005 Oct 01; 81(960):660-2. PubMed ID: 16210465 [Abstract] [Full Text] [Related]
16. Eye lens exposure to medical staff during endoscopic retrograde cholangiopancreatography. Zagorska A, Romanova K, Hristova-Popova J, Vassileva J, Katzarov K. Phys Med; 2015 Nov 01; 31(7):781-4. PubMed ID: 25937006 [Abstract] [Full Text] [Related]
17. Evaluation of patient doses due to fluoroscopic exposures. Noto K, Matsubara K, Koshida K, Iida H, Yamamoto T. Radiat Prot Dosimetry; 2011 Jul 01; 146(1-3):234-6. PubMed ID: 21561943 [Abstract] [Full Text] [Related]
18. Radiation protection effect of mobile shield barrier for the medical personnel during endoscopic retrograde cholangiopancreatography: a quasi-experimental prospective study. Chung KH, Park YS, Ahn SB, Son BK. BMJ Open; 2019 Mar 20; 9(3):e027729. PubMed ID: 30898834 [Abstract] [Full Text] [Related]
19. Radiation doses to patients undergoing enteroclysis. Sulieman A, Vlychou M, Tsougos I, Kappas C, Theodorou K. Radiat Prot Dosimetry; 2011 Sep 20; 147(1-2):122-5. PubMed ID: 21743077 [Abstract] [Full Text] [Related]
20. A double-blind, randomized, sham-controlled trial of the effect of a radiation-attenuating drape on radiation exposure to endoscopy staff during ERCP. Muniraj T, Aslanian HR, Laine L, Farrell J, Ciarleglio MM, Deng Y, Ho H, Jamidar PA. Am J Gastroenterol; 2015 May 20; 110(5):690-6. PubMed ID: 25823765 [Abstract] [Full Text] [Related] Page: [Next] [New Search]