These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
146 related items for PubMed ID: 21276887
1. The comparative stability of screw versus plate versus screw and plate coronoid fixation. Budoff JE, Meyers DN, Ambrose CG. J Hand Surg Am; 2011 Feb; 36(2):238-45. PubMed ID: 21276887 [Abstract] [Full Text] [Related]
2. Commentary on "biomechanical properties of volar hybrid and locked plate fixation in distal radius fractures". Toby EB. J Hand Surg Am; 2011 Apr; 36(4):598. PubMed ID: 21463724 [No Abstract] [Full Text] [Related]
3. Biomechanical properties of volar hybrid and locked plate fixation in distal radius fractures. Sokol SC, Amanatullah DF, Curtiss S, Szabo RM. J Hand Surg Am; 2011 Apr; 36(4):591-7. PubMed ID: 21463723 [Abstract] [Full Text] [Related]
4. Analysis of the helical plate for bone fracture fixation. Krishna KR, Sridhar I, Ghista DN. Injury; 2008 Dec; 39(12):1421-36. PubMed ID: 18823624 [Abstract] [Full Text] [Related]
5. Biomechanical Evaluation of Plate Versus Lag Screw Only Fixation of Distal Fibula Fractures. Misaghi A, Doan J, Bastrom T, Pennock AT. J Foot Ankle Surg; 2015 Dec; 54(5):896-9. PubMed ID: 25990534 [Abstract] [Full Text] [Related]
6. Supracondylar femur fracture fixation: mechanical comparison of the 95 degrees condylar side plate and screw versus 95 degrees angled blade plate. Jaakkola JI, Lundy DW, Moore T, Jones B, Ganey TM, Hutton WC. Acta Orthop Scand; 2002 Jan; 73(1):72-6. PubMed ID: 11928916 [Abstract] [Full Text] [Related]
9. Analysis of the mechanical properties of locking plates with and without screw hole inserts. Eichinger JK, Herzog JP, Arrington ED. Orthopedics; 2011 Jan 03; 34(1):19. PubMed ID: 21210620 [Abstract] [Full Text] [Related]
10. Basicervical fractures of the proximal femur. A biomechanical study of 3 internal fixation techniques. Blair B, Koval KJ, Kummer F, Zuckerman JD. Clin Orthop Relat Res; 1994 Sep 03; (306):256-63. PubMed ID: 8070205 [Abstract] [Full Text] [Related]
12. Biomechanical comparison of conventional technique versus oblique screw placement in plate fixation. Karadeniz E, Balcik BC, Demirors H, Tuncay IC. J Trauma; 2011 May 03; 70(5):E84-7. PubMed ID: 21610415 [Abstract] [Full Text] [Related]
13. Biomechanical comparison of tension band- and interfragmentary screw fixation with a new implant in transverse patella fractures. Dargel J, Gick S, Mader K, Koebke J, Pennig D. Injury; 2010 Feb 03; 41(2):156-60. PubMed ID: 19665707 [Abstract] [Full Text] [Related]
14. The effect of divergent screw placement on the initial strength of plate-to-bone fixation. Robert KQ, Chandler R, Baratta RV, Thomas KA, Harris MB. J Trauma; 2003 Dec 03; 55(6):1139-44. PubMed ID: 14676661 [Abstract] [Full Text] [Related]