These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
121 related items for PubMed ID: 21308986
21. Blood compatibility of human amniotic membrane compared with heparin-coated ePTFE for vascular tissue engineering. Kakavand M, Yazdanpanah G, Ahmadiani A, Niknejad H. J Tissue Eng Regen Med; 2017 Jun; 11(6):1701-1709. PubMed ID: 26190586 [Abstract] [Full Text] [Related]
22. Time sequence of blood activation by nanoporous alumina: Studies on platelets and complement system. Ferraz N, Ott MK, Hong J. Microsc Res Tech; 2010 Dec; 73(12):1101-9. PubMed ID: 20232464 [Abstract] [Full Text] [Related]
23. Randomized controlled trial comparing the safety and efficacy between the FUSION BIOLINE heparin-coated vascular graft and the standard expanded polytetrafluoroethylene graft for femoropopliteal bypass. Lumsden AB, Morrissey NJ, Comparison of Safety and Primary Patency Between the FUSION BIOLINE Heparin-Coated Vascular Graft and EXXCEL Soft ePTFE (FINEST) Trial Co-investigators. J Vasc Surg; 2015 Mar; 61(3):703-12.e1. PubMed ID: 25720929 [Abstract] [Full Text] [Related]
24. In vitro and in vivo evaluation of blood coagulation activation of polyvinyl alcohol hydrogel plus dextran-based vascular grafts. Alexandre N, Costa E, Coimbra S, Silva A, Lopes A, Rodrigues M, Santos M, Maurício AC, Santos JD, Luís AL. J Biomed Mater Res A; 2015 Apr; 103(4):1366-79. PubMed ID: 25044790 [Abstract] [Full Text] [Related]
25. Thrombogenicity of a new injectable biocompatible elastomer for aneurysm exclusion, compared to expanded polytetrafluoroethylene in a human ex vivo model. van der Steenhoven TJ, Bosman WM, Tersteeg C, Jacobs MJ, Moll FL, de Groot PG, Heyligers JM. Eur J Vasc Endovasc Surg; 2012 Jun; 43(6):675-80. PubMed ID: 22436262 [Abstract] [Full Text] [Related]
26. Direct synthesis of heparin-like poly(ether sulfone) polymer and its blood compatibility. Wang LR, Qin H, Nie SQ, Sun SD, Ran F, Zhao CS. Acta Biomater; 2013 Nov; 9(11):8851-63. PubMed ID: 23871943 [Abstract] [Full Text] [Related]
27. Low thrombogenicity coating of nonwoven PET fiber structures for vascular grafts. Dimitrievska S, Maire M, Diaz-Quijada GA, Robitaille L, Ajji A, Yahia L, Moreno M, Merhi Y, Bureau MN. Macromol Biosci; 2011 Apr 08; 11(4):493-502. PubMed ID: 21259437 [Abstract] [Full Text] [Related]
29. Material-specific thrombin generation following contact between metal surfaces and whole blood. Hong J, Azens A, Ekdahl KN, Granqvist CG, Nilsson B. Biomaterials; 2005 Apr 08; 26(12):1397-403. PubMed ID: 15482827 [Abstract] [Full Text] [Related]
30. An In Vitro Hemodynamic Loop Model to Investigate the Hemocytocompatibility and Host Cell Activation of Vascular Medical Devices. Wacker M, Betke U, Borucki K, Hülsmann J, Awad G, Varghese S, Scherner M, Hansen M, Wippermann J, Veluswamy P. J Vis Exp; 2020 Aug 21; (162):. PubMed ID: 32894265 [Abstract] [Full Text] [Related]
39. Activation of the plasma coagulation system induced by some biomaterials. Cenni E, Ciapetti G, Cervellati M, Cavedagna D, Falsone G, Gamberini S, Pizzoferrato A. J Biomed Mater Res; 1996 May 21; 31(1):145-8. PubMed ID: 8731159 [Abstract] [Full Text] [Related]