These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
95 related items for PubMed ID: 21320704
1. Over the limit: use of peripheral venous cannulae above the manufacturer's recommended flow rates. Proctor RD, Beckett D, Oakes JL. Clin Radiol; 2011 May; 66(5):456-8. PubMed ID: 21320704 [No Abstract] [Full Text] [Related]
2. In-line pressures generated in small-bore central venous catheters during power injection of CT contrast media. Ruess L, Bulas DI, Rivera O, Markle BM. Radiology; 1997 Jun; 203(3):625-9. PubMed ID: 9169679 [Abstract] [Full Text] [Related]
3. [Contrast media pressure injection using a portal catheter system--results of an in vitro study]. Gebauer B, Teichgräber UK, Hothan T, Felix R, Wagner HJ. Rofo; 2005 Oct; 177(10):1417-23. PubMed ID: 16170712 [Abstract] [Full Text] [Related]
4. Central venous catheter care during contrast-enhanced CT. Halpenny DF, Doody O, McNeill G, Torreggiani WC. Radiology; 2010 May; 255(2):662; author reply 662. PubMed ID: 20413780 [No Abstract] [Full Text] [Related]
5. Power injection of intravenous contrast material through central venous catheters for CT: in vitro evaluation. Herts BR, Cohen MA, McInroy B, Davros WJ, Zepp RC, Einstein DM. Radiology; 1996 Sep; 200(3):731-5. PubMed ID: 8756923 [Abstract] [Full Text] [Related]
6. Peripheral intravenous power injection of iodinated contrast media: the impact of temperature on maximum injection pressures at different cannula sizes. Schwab SA, Kuefner MA, Anders K, Adamietz B, Heinrich MC, Baigger JF, Janka R, Uder M, Kramer M. Acad Radiol; 2009 Dec; 16(12):1502-8. PubMed ID: 19896067 [Abstract] [Full Text] [Related]
7. Ultrasonographic guidance for all central venous catheter insertions: a "desirable practice alternative," or the new standard of care? Ault MJ, Rosen BT, Ault BW. Ann Emerg Med; 2007 May; 49(5):720-1. PubMed ID: 17452273 [No Abstract] [Full Text] [Related]
9. [Management of parenteral nutrition and central and peripheral venous catheters]. Copelli P. Assist Inferm Ric; 2001 Mar; 20(3):149-55. PubMed ID: 11769201 [No Abstract] [Full Text] [Related]
10. [Placement of central venous catheters and patient safety]. de Jonge E. Ned Tijdschr Geneeskd; 2007 Jan 27; 151(4):226-7. PubMed ID: 17323876 [Abstract] [Full Text] [Related]
11. An unusual case of looping of the central venous catheter: who is the culprit? Misra S, Sinha PK. J Cardiothorac Vasc Anesth; 2008 Apr 27; 22(2):336-7. PubMed ID: 18375348 [No Abstract] [Full Text] [Related]
12. Introduction of new safety technologies into central venous access. Gerstein NS, Martin HB, Toma G, Sibbitt RR, Sibbitt WL. J Clin Anesth; 2009 Aug 27; 21(5):363-5. PubMed ID: 19700280 [Abstract] [Full Text] [Related]
13. Revisiting quality standards in hemodialysis vascular access: where is the bar? Thomas A. CANNT J; 2005 Aug 27; 15(4):30-3, 36-41; quiz 34-5. PubMed ID: 16491996 [Abstract] [Full Text] [Related]
14. Targeting therapy with central venous access devices. Hadaway LC. Nursing; 2008 Jun 27; 38(6):34-40; quiz 40-1. PubMed ID: 18497658 [Abstract] [Full Text] [Related]
15. A case of fractured internal jugular catheter. Ulasi II, Ijoma CK, Anyanwu CH. Niger Postgrad Med J; 2003 Dec 27; 10(4):270-1. PubMed ID: 15045025 [Abstract] [Full Text] [Related]
16. Injection rate threshold of triple-lumen central venous catheters: an in vitro study. Zamos DT, Emch TM, Patton HA, D'Amico FJ, Bansal SK. Acad Radiol; 2007 May 27; 14(5):574-8. PubMed ID: 17434071 [Abstract] [Full Text] [Related]
17. Dialysis catheter insertion with and without peel-away sheaths. Polakovic V, Svára F, Dvoráková M. Nephrol Dial Transplant; 2007 Aug 27; 22(8):2359. PubMed ID: 17504844 [No Abstract] [Full Text] [Related]
18. Needlestick-prevention devices. Health Devices; 1994 Aug 27; 23(8-9):316-69. PubMed ID: 7860323 [No Abstract] [Full Text] [Related]