These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
171 related items for PubMed ID: 21361602
1. Adhesive-free colloidal probes for nanoscale force measurements: production and characterization. Indrieri M, Podestà A, Bongiorno G, Marchesi D, Milani P. Rev Sci Instrum; 2011 Feb; 82(2):023708. PubMed ID: 21361602 [Abstract] [Full Text] [Related]
2. Accurate noncontact calibration of colloidal probe sensitivities in atomic force microscopy. Chung KH, Shaw GA, Pratt JR. Rev Sci Instrum; 2009 Jun; 80(6):065107. PubMed ID: 19566226 [Abstract] [Full Text] [Related]
7. Attachment of micro- and nano-particles on tipless cantilevers for colloidal probe microscopy. D'Sa DJ, Chan HK, Chrzanowski W. J Colloid Interface Sci; 2014 Jul 15; 426():190-8. PubMed ID: 24863782 [Abstract] [Full Text] [Related]
8. Micro-wilhelmy and related liquid property measurements using constant-diameter nanoneedle-tipped atomic force microscope probes. Yazdanpanah MM, Hosseini M, Pabba S, Berry SM, Dobrokhotov VV, Safir A, Keynton RS, Cohn RW. Langmuir; 2008 Dec 02; 24(23):13753-64. PubMed ID: 18986184 [Abstract] [Full Text] [Related]
9. Correction of random surface roughness on colloidal probes in measuring adhesion. Yang S, Zhang H, Hsu SM. Langmuir; 2007 Jan 30; 23(3):1195-202. PubMed ID: 17241032 [Abstract] [Full Text] [Related]
10. Bubble colloidal AFM probes formed from ultrasonically generated bubbles. Vakarelski IU, Lee J, Dagastine RR, Chan DY, Stevens GW, Grieser F. Langmuir; 2008 Feb 05; 24(3):603-5. PubMed ID: 18163660 [Abstract] [Full Text] [Related]
13. A force-matching method for quantitative hardness measurements by atomic force microscopy with diamond-tipped sapphire cantilevers. Sansoz F, Gang T. Ultramicroscopy; 2010 Dec 05; 111(1):11-9. PubMed ID: 21111262 [Abstract] [Full Text] [Related]
15. Influence of Poisson's ratio variation on lateral spring constant of atomic force microscopy cantilevers. Yeh MK, Tai NH, Chen BY. Ultramicroscopy; 2008 Sep 05; 108(10):1025-9. PubMed ID: 18547729 [Abstract] [Full Text] [Related]
16. Effect of surface wettability on the adhesion of proteins. Sethuraman A, Han M, Kane RS, Belfort G. Langmuir; 2004 Aug 31; 20(18):7779-88. PubMed ID: 15323531 [Abstract] [Full Text] [Related]
19. AFM capabilities in characterization of particles and surfaces: from angstroms to microns. Starostina N, Brodsky M, Prikhodko S, Hoo CM, Mecartney ML, West P. J Cosmet Sci; 2008 Aug 31; 59(3):225-32. PubMed ID: 18528590 [Abstract] [Full Text] [Related]