These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


153 related items for PubMed ID: 2139407

  • 21.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 22. Factors affecting flow through blood administration sets.
    Stoneham MD.
    Eur J Anaesthesiol; 1997 May; 14(3):333-9. PubMed ID: 9202924
    [Abstract] [Full Text] [Related]

  • 23. Rapid infusion pump overestimates delivered flow during rapid vascular filling: a bench study.
    Le Noel A, Goffrais M, Almayrac A, Riou B, Langeron O, Raux M.
    Eur J Emerg Med; 2015 Aug; 22(4):260-5. PubMed ID: 24910964
    [Abstract] [Full Text] [Related]

  • 24.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 25. Flow characteristics of admixed erythrocytes through medex tubing with a pall filter.
    Krivchenia A, Knauf MA, Iserson KV.
    J Emerg Med; 1988 Aug; 6(4):269-71. PubMed ID: 3225428
    [Abstract] [Full Text] [Related]

  • 26. Intravenous maintenance with a saline lock intermittent infusion device in the prehospital environment.
    Carducci B, Stein K.
    Prehosp Disaster Med; 1994 Aug; 9(1):67-70. PubMed ID: 10146608
    [Abstract] [Full Text] [Related]

  • 27. Performance of three large-volume infusion pumps with the monoplace hyperbaric chamber.
    Bell J, Weaver LK, Deru K.
    Undersea Hyperb Med; 2016 Aug; 43(1):9-19. PubMed ID: 27000009
    [Abstract] [Full Text] [Related]

  • 28. Variability in infusion pressure and continuous flow rate delivered from pressurized bag pump flush systems.
    Hug MI, Buettiker V, Cornelius A, Weiss M.
    Anaesth Intensive Care; 2002 Jun; 30(3):341-7. PubMed ID: 12075643
    [Abstract] [Full Text] [Related]

  • 29. Rapid transfusion of packed red blood cells: effects of dilution, pressure, and catheter size.
    de la Roche MR, Gauthier L.
    Ann Emerg Med; 1993 Oct; 22(10):1551-5. PubMed ID: 8214834
    [Abstract] [Full Text] [Related]

  • 30. A new method for rapid fluid bolus infusion into a peripheral vein.
    Franklin WE, Patterson J, Kulick M, Sexton J.
    Prehosp Emerg Care; 1997 Oct; 1(4):273-6. PubMed ID: 9709370
    [Abstract] [Full Text] [Related]

  • 31. Do SmartSite antireflux valves limit the flow rate of 0.9% normal saline through intravenous cannulas?
    Liu D, Keijzers G.
    Eur J Emerg Med; 2013 Apr; 20(2):123-5. PubMed ID: 22828650
    [Abstract] [Full Text] [Related]

  • 32. An evaluation of the Rapid Infusion System.
    Rothen HU, Lauber R, Mosimann M.
    Anaesthesia; 1992 Jul; 47(7):597-600. PubMed ID: 1626672
    [Abstract] [Full Text] [Related]

  • 33. Use of a urologic set for improved fluid administration rates.
    Nadeau S, Tousignant M.
    Can Anaesth Soc J; 1985 May; 32(3 Pt 1):283-6. PubMed ID: 4005680
    [Abstract] [Full Text] [Related]

  • 34. The effect of large-bore infusion tubing on rates of flow through different cannulas.
    Edge KR.
    S Afr J Surg; 1986 Sep; 24(3):112-3. PubMed ID: 3824083
    [No Abstract] [Full Text] [Related]

  • 35. The properties of an improvised piston pump for the rapid delivery of intravenous fluids.
    Smart CM, Primrose CW, Peters AL, Speirits EJ.
    Anaesthesia; 2014 Feb; 69(2):111-7. PubMed ID: 24383681
    [Abstract] [Full Text] [Related]

  • 36. Specialized delivery systems for intravenous nitroglycerin. Are they necessary?
    Young JB, Pratt CM, Farmer JA, Luck JC, Fennell WH, Roberts R.
    Am J Med; 1984 Jun 22; 76(6A):27-37. PubMed ID: 6430075
    [Abstract] [Full Text] [Related]

  • 37. Comparative flow rates for small bore peripheral intravenous catheters.
    Rosen KR, Rosen DA.
    Pediatr Emerg Care; 1986 Sep 22; 2(3):153-6. PubMed ID: 3786219
    [Abstract] [Full Text] [Related]

  • 38. High-flow sheaths for pediatric fluid resuscitation: a comparison of flow rates with standard pediatric catheters.
    Idris AH, Melker RJ.
    Pediatr Emerg Care; 1992 Jun 22; 8(3):119-22. PubMed ID: 1614899
    [Abstract] [Full Text] [Related]

  • 39. A randomized trial of 72- versus 24-hour intravenous tubing set changes in newborns receiving lipid therapy.
    Matlow AG, Kitai I, Kirpalani H, Chapman NH, Corey M, Perlman M, Pencharz P, Jewell S, Phillips-Gordon C, Summerbell R, Ford-Jones EL.
    Infect Control Hosp Epidemiol; 1999 Jul 22; 20(7):487-93. PubMed ID: 10432161
    [Abstract] [Full Text] [Related]

  • 40. IV DripAssist: An Innovative Way to Monitor Intravenous Infusions Away From an Outlet?
    Couperus K, Kmiecik K, Kang C.
    Mil Med; 2019 Mar 01; 184(Suppl 1):322-325. PubMed ID: 30901392
    [Abstract] [Full Text] [Related]


    Page: [Previous] [Next] [New Search]
    of 8.