These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
5. Continuous-flow polymerase chain reaction of single-copy DNA in microfluidic microdroplets. Schaerli Y, Wootton RC, Robinson T, Stein V, Dunsby C, Neil MA, French PM, Demello AJ, Abell C, Hollfelder F. Anal Chem; 2009 Jan 01; 81(1):302-6. PubMed ID: 19055421 [Abstract] [Full Text] [Related]
6. Pressure-driven one-step solid phase-based on-chip sample preparation on a microfabricated plastic device and integration with flow-through polymerase chain reaction (PCR). Tran HH, Trinh KT, Lee NY. J Chromatogr B Analyt Technol Biomed Life Sci; 2013 Oct 01; 936():88-94. PubMed ID: 24001873 [Abstract] [Full Text] [Related]
7. Circumventing air bubbles in microfluidic systems and quantitative continuous-flow PCR applications. Nakayama T, Kurosawa Y, Furui S, Kerman K, Kobayashi M, Rao SR, Yonezawa Y, Nakano K, Hino A, Yamamura S, Takamura Y, Tamiya E. Anal Bioanal Chem; 2006 Nov 01; 386(5):1327-33. PubMed ID: 16896609 [Abstract] [Full Text] [Related]
13. Numeric simulation of heat transfer and electrokinetic flow in an electroosmosis-based continuous flow PCR chip. Gui L, Ren CL. Anal Chem; 2006 Sep 01; 78(17):6215-22. PubMed ID: 16944904 [Abstract] [Full Text] [Related]
14. Analytical study of a microfludic DNA amplification chip using water cooling effect. Chen JJ, Shen CM, Ko YW. Biomed Microdevices; 2013 Apr 01; 15(2):261-78. PubMed ID: 23179465 [Abstract] [Full Text] [Related]
16. Microfluidic handling of PCR solution and DNA amplification on a reaction chamber array biochip. Gong H, Ramalingam N, Chen L, Che J, Wang Q, Wang Y, Yang X, Yap PH, Neo CH. Biomed Microdevices; 2006 Jun 01; 8(2):167-76. PubMed ID: 16688576 [Abstract] [Full Text] [Related]
17. Effect of substrate thermal resistance on space-domain microchannel fluorescent melting curve analysis. Kinahan DJ, Dalton TM, Davies MR. Biomed Microdevices; 2009 Aug 01; 11(4):747-54. PubMed ID: 19259825 [Abstract] [Full Text] [Related]
18. Electrokinetically synchronized polymerase chain reaction microchip fabricated in polycarbonate. Chen J, Wabuyele M, Chen H, Patterson D, Hupert M, Shadpour H, Nikitopoulos D, Soper SA. Anal Chem; 2005 Jan 15; 77(2):658-66. PubMed ID: 15649068 [Abstract] [Full Text] [Related]
19. A micro circulating PCR chip using a suction-type membrane for fluidic transport. Chien LJ, Wang JH, Hsieh TM, Chen PH, Chen PJ, Lee DS, Luo CH, Lee GB. Biomed Microdevices; 2009 Apr 15; 11(2):359-67. PubMed ID: 18975094 [Abstract] [Full Text] [Related]
20. Rapid nested-PCR for tyrosinase gene detection on chip. Sciancalepore AG, Polini A, Mele E, Girardo S, Cingolani R, Pisignano D. Biosens Bioelectron; 2011 Jan 15; 26(5):2711-5. PubMed ID: 20926276 [Abstract] [Full Text] [Related] Page: [Next] [New Search]