These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
277 related items for PubMed ID: 21673383
1. Error in dynamic spring constant calibration of atomic force microscope probes due to nonuniform cantilevers. Frentrup H, Allen MS. Nanotechnology; 2011 Jul 22; 22(29):295703. PubMed ID: 21673383 [Abstract] [Full Text] [Related]
2. Quantitative comparison of two independent lateral force calibration techniques for the atomic force microscope. Barkley SS, Deng Z, Gates RS, Reitsma MG, Cannara RJ. Rev Sci Instrum; 2012 Feb 22; 83(2):023707. PubMed ID: 22380099 [Abstract] [Full Text] [Related]
3. Accuracy of the spring constant of atomic force microscopy cantilevers by finite element method. Chen BY, Yeh MK, Tai NH. Anal Chem; 2007 Feb 15; 79(4):1333-8. PubMed ID: 17297931 [Abstract] [Full Text] [Related]
4. Accurate measurement of Atomic Force Microscope cantilever deflection excluding tip-surface contact with application to force calibration. Slattery AD, Blanch AJ, Quinton JS, Gibson CT. Ultramicroscopy; 2013 Aug 15; 131():46-55. PubMed ID: 23685172 [Abstract] [Full Text] [Related]
5. Calibration of the spring constant of cantilevers of arbitrary shape using the phase signal in an atomic force microscope. Rawlings C, Durkan C. Nanotechnology; 2012 Dec 07; 23(48):485708. PubMed ID: 23137943 [Abstract] [Full Text] [Related]
6. Calibration of higher eigenmode spring constants of atomic force microscope cantilevers. Lozano JR, Kiracofe D, Melcher J, Garcia R, Raman A. Nanotechnology; 2010 Nov 19; 21(46):465502. PubMed ID: 20972309 [Abstract] [Full Text] [Related]
7. Precise atomic force microscope cantilever spring constant calibration using a reference cantilever array. Gates RS, Reitsma MG. Rev Sci Instrum; 2007 Aug 19; 78(8):086101. PubMed ID: 17764361 [Abstract] [Full Text] [Related]
8. Accurate flexural spring constant calibration of colloid probe cantilevers using scanning laser Doppler vibrometry. Gates RS, Osborn WA, Shaw GA. Nanotechnology; 2015 Jun 12; 26(23):235704. PubMed ID: 25990652 [Abstract] [Full Text] [Related]
9. Atomic force microscope cantilever calibration using a focused ion beam. Slattery AD, Quinton JS, Gibson CT. Nanotechnology; 2012 Jul 20; 23(28):285704. PubMed ID: 22728463 [Abstract] [Full Text] [Related]
10. Atomic force microscope cantilever spring constant evaluation for higher mode oscillations: a kinetostatic method. Tseytlin YM. Rev Sci Instrum; 2008 Feb 20; 79(2 Pt 1):025102. PubMed ID: 18315324 [Abstract] [Full Text] [Related]
12. Accurate and precise calibration of AFM cantilever spring constants using laser Doppler vibrometry. Gates RS, Pratt JR. Nanotechnology; 2012 Sep 21; 23(37):375702. PubMed ID: 22922668 [Abstract] [Full Text] [Related]
13. Study of thermal and acoustic noise interferences in low stiffness atomic force microscope cantilevers and characterization of their dynamic properties. Boudaoud M, Haddab Y, Le Gorrec Y, Lutz P. Rev Sci Instrum; 2012 Jan 21; 83(1):013704. PubMed ID: 22299959 [Abstract] [Full Text] [Related]
14. Cantilever spring constant calibration using laser Doppler vibrometry. Ohler B. Rev Sci Instrum; 2007 Jun 21; 78(6):063701. PubMed ID: 17614610 [Abstract] [Full Text] [Related]
15. Nondestructive and noncontact method for determining the spring constant of rectangular cantilevers. Golovko DS, Haschke T, Wiechert W, Bonaccurso E. Rev Sci Instrum; 2007 Apr 21; 78(4):043705. PubMed ID: 17477668 [Abstract] [Full Text] [Related]
18. Calibration of atomic force microscope cantilevers using standard and inverted static methods assisted by FIB-milled spatial markers. Slattery AD, Blanch AJ, Quinton JS, Gibson CT. Nanotechnology; 2013 Jan 11; 24(1):015710. PubMed ID: 23220746 [Abstract] [Full Text] [Related]
19. Effects of anisotropic material property on the spring constant and the resonant frequency of atomic force microscope cantilever. Yeh MK, Tai NH, Chen BY. Rev Sci Instrum; 2009 Apr 11; 80(4):043705. PubMed ID: 19405664 [Abstract] [Full Text] [Related]