These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
279 related items for PubMed ID: 21715121
1. Detection of counterfeit Viagra® by Raman microspectroscopy imaging and multivariate analysis. Sacré PY, Deconinck E, Saerens L, De Beer T, Courselle P, Vancauwenberghe R, Chiap P, Crommen J, De Beer JO. J Pharm Biomed Anal; 2011 Sep 10; 56(2):454-61. PubMed ID: 21715121 [Abstract] [Full Text] [Related]
2. Impurity fingerprints for the identification of counterfeit medicines--a feasibility study. Sacré PY, Deconinck E, Daszykowski M, Courselle P, Vancauwenberghe R, Chiap P, Crommen J, De Beer JO. Anal Chim Acta; 2011 Sep 09; 701(2):224-31. PubMed ID: 21801892 [Abstract] [Full Text] [Related]
3. Detection of counterfeit Viagra with Raman spectroscopy. de Veij M, Deneckere A, Vandenabeele P, de Kaste D, Moens L. J Pharm Biomed Anal; 2008 Jan 22; 46(2):303-9. PubMed ID: 18054194 [Abstract] [Full Text] [Related]
4. Fingerprinting of sildenafil citrate and tadalafil tablets in pharmaceutical formulations via X-ray fluorescence (XRF) spectrometry. Ortiz RS, Mariotti KC, Schwab NV, Sabin GP, Rocha WF, de Castro EV, Limberger RP, Mayorga P, Bueno MI, Romão W. J Pharm Biomed Anal; 2012 Jan 25; 58():7-11. PubMed ID: 22014651 [Abstract] [Full Text] [Related]
5. Development and validation of a ultra-high-performance liquid chromatography-UV method for the detection and quantification of erectile dysfunction drugs and some of their analogues found in counterfeit medicines. Sacré PY, Deconinck E, Chiap P, Crommen J, Mansion F, Rozet E, Courselle P, De Beer JO. J Chromatogr A; 2011 Sep 16; 1218(37):6439-47. PubMed ID: 21835410 [Abstract] [Full Text] [Related]
6. Analysis of counterfeit Cialis® tablets using Raman microscopy and multivariate curve resolution. Kwok K, Taylor LS. J Pharm Biomed Anal; 2012 Jul 16; 66():126-35. PubMed ID: 22494518 [Abstract] [Full Text] [Related]
7. Screening suspected counterfeit Viagra and imitations of Viagra with near-infrared spectroscopy. Vredenbregt MJ, Blok-Tip L, Hoogerbrugge R, Barends DM, de Kaste D. J Pharm Biomed Anal; 2006 Mar 03; 40(4):840-9. PubMed ID: 16229983 [Abstract] [Full Text] [Related]
8. Chemometrics and chromatographic fingerprints to discriminate and classify counterfeit medicines containing PDE-5 inhibitors. Deconinck E, Sacré PY, Courselle P, De Beer JO. Talanta; 2012 Oct 15; 100():123-33. PubMed ID: 23141319 [Abstract] [Full Text] [Related]
9. [Counterfeit phosphodiesterase type 5 inhibitors--growing safety risks for public health]. Fijałek Z, Sarna K, Błazewicz A, Marin J. Rocz Panstw Zakl Hig; 2010 Oct 15; 61(3):227-35. PubMed ID: 21365856 [Abstract] [Full Text] [Related]
10. Headspace-gas chromatographic fingerprints to discriminate and classify counterfeit medicines. Custers D, Canfyn M, Courselle P, De Beer JO, Apers S, Deconinck E. Talanta; 2014 Jun 15; 123():78-88. PubMed ID: 24725867 [Abstract] [Full Text] [Related]
11. The usefulness of simple X-ray powder diffraction analysis for counterfeit control--the Viagra example. Maurin JK, Pluciński F, Mazurek AP, Fijałek Z. J Pharm Biomed Anal; 2007 Mar 12; 43(4):1514-8. PubMed ID: 17127026 [Abstract] [Full Text] [Related]
12. Comparison and combination of spectroscopic techniques for the detection of counterfeit medicines. Sacré PY, Deconinck E, De Beer T, Courselle P, Vancauwenberghe R, Chiap P, Crommen J, De Beer JO. J Pharm Biomed Anal; 2010 Nov 02; 53(3):445-53. PubMed ID: 20542652 [Abstract] [Full Text] [Related]
13. Detection of Lipitor counterfeits: a comparison of NIR and Raman spectroscopy in combination with chemometrics. de Peinder P, Vredenbregt MJ, Visser T, de Kaste D. J Pharm Biomed Anal; 2008 Aug 05; 47(4-5):688-94. PubMed ID: 18387769 [Abstract] [Full Text] [Related]
14. Classification trees based on infrared spectroscopic data to discriminate between genuine and counterfeit medicines. Deconinck E, Sacré PY, Coomans D, De Beer J. J Pharm Biomed Anal; 2012 Jan 05; 57():68-75. PubMed ID: 21940132 [Abstract] [Full Text] [Related]
15. Evaluation of the residual solvent content of counterfeit tablets and capsules. Deconinck E, Canfyn M, Sacré PY, Courselle P, De Beer JO. J Pharm Biomed Anal; 2013 Jan 05; 81-82():80-8. PubMed ID: 23628524 [Abstract] [Full Text] [Related]
16. Physical profiling and IR spectroscopy: simple and effective methods to discriminate between genuine and counterfeit samples of Viagra® and Cialis®. Custers D, Vandemoortele S, Bothy JL, De Beer JO, Courselle P, Apers S, Deconinck E. Drug Test Anal; 2016 Jan 05; 8(3-4):378-87. PubMed ID: 26033891 [Abstract] [Full Text] [Related]
17. Determination of counterfeit medicines by Raman spectroscopy: Systematic study based on a large set of model tablets. Neuberger S, Neusüß C. J Pharm Biomed Anal; 2015 Aug 10; 112():70-8. PubMed ID: 25956227 [Abstract] [Full Text] [Related]
18. ATR-FTIR spectroscopy and chemometrics: An interesting tool to discriminate and characterize counterfeit medicines. Custers D, Cauwenbergh T, Bothy JL, Courselle P, De Beer JO, Apers S, Deconinck E. J Pharm Biomed Anal; 2015 Aug 10; 112():181-9. PubMed ID: 25476739 [Abstract] [Full Text] [Related]
19. Near infrared spectroscopy for counterfeit detection using a large database of pharmaceutical tablets. Dégardin K, Guillemain A, Guerreiro NV, Roggo Y. J Pharm Biomed Anal; 2016 Sep 05; 128():89-97. PubMed ID: 27236101 [Abstract] [Full Text] [Related]
20. Internet-ordered viagra (sildenafil citrate) is rarely genuine. Campbell N, Clark JP, Stecher VJ, Goldstein I. J Sex Med; 2012 Nov 05; 9(11):2943-51. PubMed ID: 22925379 [Abstract] [Full Text] [Related] Page: [Next] [New Search]