These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
138 related items for PubMed ID: 21757607
1. Use of the BD vacutainer rapid serum tube reduces false-positive results for selected beckman coulter Unicel DxI immunoassays. Strathmann FG, Ka MM, Rainey PM, Baird GS. Am J Clin Pathol; 2011 Aug; 136(2):325-9. PubMed ID: 21757607 [Abstract] [Full Text] [Related]
3. Evaluation of the BD Vacutainer(®) RST blood collection tube for routine chemistry analytes: clinical significance of differences and stability study. Kocijancic M, Cargonja J, Delic-Knezevic A. Biochem Med (Zagreb); 2014 Jul; 24(3):368-75. PubMed ID: 25351355 [Abstract] [Full Text] [Related]
4. Evaluation of the BD Vacutainer PST II blood collection tube for special chemistry analytes. Chance J, Berube J, Vandersmissen M, Blanckaert N. Clin Chem Lab Med; 2009 Jul; 47(3):358-61. PubMed ID: 19676149 [Abstract] [Full Text] [Related]
5. Comparison of BD Vacutainer® Rapid Serum Tube and plasma for haemolysis markers in the emergency department. Ryan JB, Stuart LA, Southby SJ, Than MP, Mackay R, Florkowski CM, George PM. Ann Clin Biochem; 2015 Mar; 52(Pt 2):293-6. PubMed ID: 24714681 [Abstract] [Full Text] [Related]
6. Comparison of Bayer Advia Centaur immunoassay results obtained on samples collected in four different Becton Dickinson Vacutainer tubes. Morovat A, James TS, Cox SD, Norris SG, Rees MC, Gales MA, Taylor RP. Ann Clin Biochem; 2006 Nov; 43(Pt 6):481-7. PubMed ID: 17132279 [Abstract] [Full Text] [Related]
7. Results from a multicenter evaluation of the 4th generation Elecsys Troponin T assay. Hermsen D, Apple F, Garcia-Beltràn L, Jaffe A, Karon B, Lewandrowski E, Mühlbacher A, Müller R, Ordóñez J, Pagani F, Panteghini M, Plecko T, Jarausch J. Clin Lab; 2007 Nov; 53(1-2):1-9. PubMed ID: 17323819 [Abstract] [Full Text] [Related]
8. Test results comparison and sample stability study: is the BD Barricor tube a suitable replacement for the BD RST tube? Mandić S, Mandić D, Lukić I, Rolić T, Horvat V, Lukić M, Osvald S, Šerić V. Biochem Med (Zagreb); 2020 Oct 15; 30(3):030704. PubMed ID: 33071555 [Abstract] [Full Text] [Related]
9. The BD Barricor blood collection tube is an acceptable and robust alternative to the PST for use with the Beckman AccuTnI+3 assay. Füzéry AK, Raizman JE, Goudreau BL, Moses K, Niemann K, Park J, Cembrowski GS. Clin Biochem; 2017 Oct 15; 50(15):851-857. PubMed ID: 28583435 [Abstract] [Full Text] [Related]
10. Incomplete filling of lithium heparin tubes affects the activity of creatine kinase and gamma-glutamyltransferase. Lippi G, Avanzini P, Cosmai M, Aloe R, Ernst D. Br J Biomed Sci; 2012 Oct 15; 69(2):67-70. PubMed ID: 22872930 [Abstract] [Full Text] [Related]
11. Evaluation of the Greiner Bio-One serum separator BCA Fast Clot tube. Dimeski G, Johnston J, Masci PP, Zhao KN, Brown N. Clin Chem Lab Med; 2017 Jul 26; 55(8):1135-1141. PubMed ID: 28076307 [Abstract] [Full Text] [Related]
12. Barricor blood collection tubes are equivalent to PST for a variety of chemistry and immunoassay analytes except for lactate dehydrogenase. Raizman JE, Goudreau BL, Füzéry AK, Cembrowski GS. Clin Chim Acta; 2019 Sep 26; 496():18-24. PubMed ID: 31201816 [Abstract] [Full Text] [Related]
13. Evaluation of the Becton-Dickinson rapid serum tube: does it provide a suitable alternative to lithium heparin plasma tubes? Dimeski G, Masci PP, Trabi M, Lavin MF, de Jersey J. Clin Chem Lab Med; 2010 May 26; 48(5):651-7. PubMed ID: 20218902 [Abstract] [Full Text] [Related]
14. Evaluation of BD Barricor™ Plasma Blood Collection Tube for Biochemical Tests. Kösem A, Topçuoğlu C, Sezer S, Cevher ŞK, Yenigün EC, Dede F, Turhan T. Clin Lab; 2019 Dec 01; 65(12):. PubMed ID: 31850716 [Abstract] [Full Text] [Related]
15. Thrombin-mediated degradation of parathyroid hormone in serum tubes. La'ulu SL, Straseski JA, Schmidt RL, Genzen JR. Clin Chim Acta; 2014 Nov 01; 437():191-6. PubMed ID: 25086279 [Abstract] [Full Text] [Related]
16. Comparison of Improvacuter™ tubes with BD Vacutainer™ tubes for various hormones in the aspects of stability and influence of gel separators. Zungun C, Yılmaz FM, Boru EG, Topcuoglu C. Clin Chem Lab Med; 2015 Feb 01; 53(2):231-8. PubMed ID: 25153600 [Abstract] [Full Text] [Related]
17. Comparison of Becton Dickinson Vacutainer rapid serum tube with the serum separator tube for routine chemistry and immunoassay tests. Yan R, Lou A, Watts G, Tarr H, Smith H, Kinney L, Chen Y. J Clin Pathol; 2014 Jul 01; 67(7):599-604. PubMed ID: 24687321 [Abstract] [Full Text] [Related]
18. False-positive troponin I measured with the Abbott AxSYM attributed to fibrin interference. Kazmierczak SC, Sekhon H, Richards C. Int J Cardiol; 2005 May 11; 101(1):27-31. PubMed ID: 15860379 [Abstract] [Full Text] [Related]
19. Thyroglobulin measurement on fine-needle washout fluids: Influence of sample collection methods. Giovanella L, Ceriani L, Suriano S, Crippa S. Diagn Cytopathol; 2009 Jan 11; 37(1):42-4. PubMed ID: 18973125 [Abstract] [Full Text] [Related]
20. Creatine-kinase MB mass: age and sex-associated reference limits in two different platforms that use the same method. Zaninotto M, Mion MM, Novello E, Delprete E, Moretti M, Plebani M. Clin Chim Acta; 2009 Mar 11; 401(1-2):162-4. PubMed ID: 19101529 [Abstract] [Full Text] [Related] Page: [Next] [New Search]