These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


76 related items for PubMed ID: 21774209

  • 1. [Biomechanical evaluation of monosegmental and bisegmental anterior fixation for thoracolumbar burst fracture].
    Liang T, Lin H, Feng G, Huang H, Zhao X.
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2011 Jun; 28(3):491-6. PubMed ID: 21774209
    [Abstract] [Full Text] [Related]

  • 2. Transpedicular fixation in management of thoracolumbar burst fractures: monosegmental fixation versus short-segment instrumentation.
    Wei FX, Liu SY, Liang CX, Li HM, Long HQ, Yu BS, Chen BL, Chen KB.
    Spine (Phila Pa 1976); 2010 Jul 01; 35(15):E714-20. PubMed ID: 20535041
    [Abstract] [Full Text] [Related]

  • 3. Biomechanical effect of the extent of vertebral body fracture on the thoracolumbar spine with pedicle screw fixation: an in vitro study.
    Wang XY, Dai LY, Xu HZ, Chi YL.
    J Clin Neurosci; 2008 Mar 01; 15(3):286-90. PubMed ID: 18226530
    [Abstract] [Full Text] [Related]

  • 4. Monosegmental anterior column reconstruction using an expandable vertebral body replacement device in combined posterior-anterior stabilization of thoracolumbar burst fractures.
    Lindtner RA, Mueller M, Schmid R, Spicher A, Zegg M, Kammerlander C, Krappinger D.
    Arch Orthop Trauma Surg; 2018 Jul 01; 138(7):939-951. PubMed ID: 29623406
    [Abstract] [Full Text] [Related]

  • 5. [The biomechanical study and clinical application of monosegmental pedicle instrumentation by endplate method in the fracture vertebrae for thoracolumbar fracture].
    Xu ZW, Zhuang QS, Wang BW, Sui GX, Li F, Liu WQ, Ji XB.
    Zhonghua Wai Ke Za Zhi; 2009 Feb 01; 47(3):194-6. PubMed ID: 19563073
    [Abstract] [Full Text] [Related]

  • 6. [Selective treatment of thoracolumbar fracture with posterior monosegmental pedicle screw fixation].
    Gu YJ, Hu Y, Ma WH, Xu RM, Sun SH.
    Zhongguo Gu Shang; 2009 Jul 01; 22(7):491-3. PubMed ID: 19705704
    [Abstract] [Full Text] [Related]

  • 7. Biomechanical evaluation of short-segment posterior instrumentation with and without crosslinks in a human cadaveric unstable thoracolumbar burst fracture model.
    Wahba GM, Bhatia N, Bui CN, Lee KH, Lee TQ.
    Spine (Phila Pa 1976); 2010 Feb 01; 35(3):278-85. PubMed ID: 20075769
    [Abstract] [Full Text] [Related]

  • 8. In vitro analysis of anterior and posterior fixation in an experimental unstable burst fracture model.
    Kallemeier PM, Beaubien BP, Buttermann GR, Polga DJ, Wood KB.
    J Spinal Disord Tech; 2008 May 01; 21(3):216-24. PubMed ID: 18458594
    [Abstract] [Full Text] [Related]

  • 9. Monosegmental vs bisegmental pedicle fixation for the treatment of thoracolumbar spine fractures.
    La Maida GA, Luceri F, Ferraro M, Ruosi C, Mineo GV, Misaggi B.
    Injury; 2016 Oct 01; 47 Suppl 4():S35-S43. PubMed ID: 27553389
    [Abstract] [Full Text] [Related]

  • 10. [Influence of two kinds of bone grafting methods on bone defect gap residual rates and compressive stiffness after reduction of thoracolumbar burst fracture].
    Ao J, Xin Z, Chen F, Xin X, Liao W.
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2013 Aug 01; 27(8):974-9. PubMed ID: 24171354
    [Abstract] [Full Text] [Related]

  • 11. [Vibration test for evaluating the spinal stability following fixation of thoracolumbar burst fracture in pigs].
    Yang XJ, Wang ZG, Guo XY.
    Nan Fang Yi Ke Da Xue Xue Bao; 2011 Nov 01; 31(11):1922-5. PubMed ID: 22126781
    [Abstract] [Full Text] [Related]

  • 12. Anterior decompression and fixation versus posterior reposition and semirigid fixation in the treatment of unstable burst thoracolumbar fracture: prospective clinical trial.
    Stancić MF, Gregorović E, Nozica E, Penezić L.
    Croat Med J; 2001 Feb 01; 42(1):49-53. PubMed ID: 11172655
    [Abstract] [Full Text] [Related]

  • 13. Biomechanical effects of pedicle screw adjustments on the thoracolumbar burst fractures.
    Shang J, Ling XD, Liu YC, Liu W, Xiao XG, Yuan SH.
    Chin Med J (Engl); 2013 Jan 01; 126(2):300-5. PubMed ID: 23324281
    [Abstract] [Full Text] [Related]

  • 14. The use of X-shaped cross-link in posterior spinal constructs improves stability in thoracolumbar burst fracture: a finite element analysis.
    Alizadeh M, Kadir MR, Fadhli MM, Fallahiarezoodar A, Azmi B, Murali MR, Kamarul T.
    J Orthop Res; 2013 Sep 01; 31(9):1447-54. PubMed ID: 23640802
    [Abstract] [Full Text] [Related]

  • 15. [Minimally invasive thoracoscopic transdiaphragmatic approach to thoracolumbar junction fractures].
    Kocis J, Wendsche P, Muzík V, Bilik A, Veselý R, Cernohousová I.
    Acta Chir Orthop Traumatol Cech; 2009 Jun 01; 76(3):232-8. PubMed ID: 19595286
    [Abstract] [Full Text] [Related]

  • 16.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 17.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 18.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 19. [Minimally invasive percutanuous cannulated pedicle screw system fixation for the treatment of thoracolumbar flexion-distraction fracture without neurologic impairment].
    Zhang ZC, Sun TS, Liu Z, Guo YZ, Li LH.
    Zhongguo Gu Shang; 2011 Oct 01; 24(10):802-5. PubMed ID: 22097123
    [Abstract] [Full Text] [Related]

  • 20. Prospective randomized controlled comparison of posterior vs. posterior-anterior stabilization of thoracolumbar incomplete cranial burst fractures in neurological intact patients: the RASPUTHINE pilot study.
    Scholz M, Kandziora F, Tschauder T, Kremer M, Pingel A.
    Eur Spine J; 2018 Dec 01; 27(12):3016-3024. PubMed ID: 29071409
    [Abstract] [Full Text] [Related]


    Page: [Next] [New Search]
    of 4.