21. Measuring creatine kinase MB isoenzyme in a maintenance hemodialysis population: chemiluminometric immunoassay and electrophoresis compared. Latner BP, Skale JS, Burns W. Clin Chem; 1989 Sep; 35(9):1965-8. PubMed ID: 2776327 [Abstract] [Full Text] [Related]
22. At what level of serum total creatine kinase activity can measurement of serum creatine kinase MB isoenzyme activity be omitted in suspected myocardial infarction? Knudsen J, Steenstrup B, Byrjalsen I, Hildebrandt P, Sørensen S. Scand J Clin Lab Invest; 1989 Nov; 49(7):661-5. PubMed ID: 2609109 [Abstract] [Full Text] [Related]
23. Immunoenzymetric assay for creatine kinase MB with subunit-specific monoclonal antibodies compared with an immunochemical method and electrophoresis. Chan DW, Taylor E, Frye R, Blitzer RL. Clin Chem; 1985 Mar; 31(3):465-9. PubMed ID: 3882277 [Abstract] [Full Text] [Related]
24. IgA-CK-BB complex with CK-MB electrophoretic mobility can lead to erroneous diagnosis of acute myocardial infarction. Venta R, Geijo SA, Sánchez AC, Bao CG, Bartolome LA, Casares G, Lopez-Otin C, Alvarez FV. Clin Chem; 1989 Sep; 35(9):2003-8. PubMed ID: 2776341 [Abstract] [Full Text] [Related]
25. Differentiation of creatine kinase MB and IgA-linked BB isoenzymes on electrophoresis. Chen A, Wong SS. FEBS Lett; 1987 Apr 06; 214(1):192-4. PubMed ID: 3494633 [Abstract] [Full Text] [Related]
26. Clinical and analytical evaluation of kits for measurement of creatine kinase isoenzyme MB. Koch TR, Mehta UJ, Nipper HC. Clin Chem; 1986 Jan 06; 32(1 Pt 1):186-91. PubMed ID: 3940705 [Abstract] [Full Text] [Related]
27. Development and performance of an enzyme immunoassay to detect creatine kinase isoenzyme MB activity using anti-mitochondrial creatine kinase monoclonal antibodies. Hoshino T, Sakai Y, Yamashita K, Shirahase Y, Sakaguchi K, Asaeda A, Kishi K, Schlattner U, Wallimann T, Yanai M, Kumasaka K. Scand J Clin Lab Invest; 2009 Jan 06; 69(6):687-95. PubMed ID: 19484658 [Abstract] [Full Text] [Related]
31. Direct measurement of creatine kinase-MB activity in serum after extraction with a monoclonal antibody specific to the MB isoenzyme. Vaidya HC, Maynard Y, Dietzler DN, Ladenson JH. Clin Chem; 1986 Apr 06; 32(4):657-63. PubMed ID: 3955814 [Abstract] [Full Text] [Related]
32. Immunoenzymometric assay of creatine kinase with monoclonal antibodies to the MB isoenzyme compared with electrophoresis. Hall M, Neisler M, Johnson JT. Clin Chem; 1988 Dec 06; 34(12):2539-42. PubMed ID: 3058366 [Abstract] [Full Text] [Related]
33. Kinetic immunochemical method for the simultaneous quantification of creatine kinase isoenzymes. Weiser WE, Pardue HL. Clin Chem; 1987 Feb 06; 33(2 Pt 1):237-42. PubMed ID: 3802506 [Abstract] [Full Text] [Related]
34. [Evaluation of infarct size using serum concentration of the CK-MB isoenzyme (author's transl)]. Kupper W, Bleifeld W, Hanrath P, Effert S. Dtsch Med Wochenschr; 1978 Mar 31; 103(13):550-6. PubMed ID: 639686 [Abstract] [Full Text] [Related]
35. Relative increase in creatine kinase MB isoenzyme during reperfusion after myocardial infarction is method dependent. Christenson RH, Clemmensen P, Ohman EM, Toffaletti J, Silverman LM, Grande P, Vollmer RT, Wagner GS. Clin Chem; 1990 Aug 31; 36(8 Pt 1):1444-9. PubMed ID: 2387040 [Abstract] [Full Text] [Related]
37. Creatine kinase isoenzyme MB assay by electrophoresis. Grande P, Christiansen C, Naestoft J. Scand J Clin Lab Invest; 1979 Nov 31; 39(7):607-12. PubMed ID: 531487 [Abstract] [Full Text] [Related]
38. Automated quantification of creatine kinase MB isoenzyme in serum by radial partition immunoassay, with use of the Stratus analyzer. Chapelle JP, el Allaf M. Clin Chem; 1990 Jan 31; 36(1):99-101. PubMed ID: 2404644 [Abstract] [Full Text] [Related]