These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
435 related items for PubMed ID: 21793169
1. Migrating type A intramural hematoma after repair of an anomalous right coronary artery aortocoronary dissection with a covered stent. Fang HY, Wu CJ. Catheter Cardiovasc Interv; 2011 Oct 01; 78(4):573-6. PubMed ID: 21793169 [Abstract] [Full Text] [Related]
8. Aortic dissection complicating failed coronary stenting. Kagoshima M, Kobayashi C, Owa M. J Invasive Cardiol; 2002 May 01; 14(5):263-5. PubMed ID: 11983948 [Abstract] [Full Text] [Related]
9. A Case of Iatrogenic Aortic Intramural Hematoma. Muhyieddeen K, Samim A, Roberts M, Srikanth S. Methodist Debakey Cardiovasc J; 2017 May 01; 13(1):37-38. PubMed ID: 28413582 [Abstract] [Full Text] [Related]
10. Guidewire-induced dissection of the right coronary artery and adjacent aortic wall during percutaneous coronary angioplasty. Hung MJ, Kuo LT, Wang CH, Cherng WJ. Int J Clin Pract; 2002 Nov 01; 56(9):718-9. PubMed ID: 12469989 [Abstract] [Full Text] [Related]
11. Perforation of the sinus of Valsalva by guiding catheter during the percutaneous coronary intervention via the right transradial approach: a very unusual complication. Tomassini F, Gagnor A, Varbella F. Catheter Cardiovasc Interv; 2011 Nov 15; 78(6):888-91. PubMed ID: 21523896 [Abstract] [Full Text] [Related]
13. Expanding subintimal coronary dissection under a stent-covered arterial segment: serial intravascular ultrasound observations. Martí V, Montiel J, Aymat RM, García J, Guiteras P, Kozak F, Augé JM. Catheter Cardiovasc Interv; 1999 Nov 15; 48(3):308-11. PubMed ID: 10525236 [Abstract] [Full Text] [Related]
14. Multiple MGuard stent implantation to treat massive right coronary artery dissection during primary coronary angioplasty. Rapacciuolo A, D'andrea C, Maresca G, di Pietro E, Piscione F, Chiariello M. J Cardiovasc Med (Hagerstown); 2011 May 15; 12(5):356-60. PubMed ID: 20093945 [Abstract] [Full Text] [Related]
15. Intramural hematoma squeeze causing carina shift during stent deployment. A preventable complication of coronary artery dissection treatment? Gallo F, Mangieri A, Laricchia A, Fisicaro A, Colombo A, Giannini F. Int J Cardiovasc Imaging; 2020 Jan 15; 36(1):9-11. PubMed ID: 31512010 [No Abstract] [Full Text] [Related]
16. Successful stenting of catheter-induced unprotected left main coronary artery dissection. Ertaş G, Ural E, Van der Giessen WJ. Cardiovasc J Afr; 2012 May 12; 23(4):e6-7. PubMed ID: 22614702 [Abstract] [Full Text] [Related]
18. Left main artery dissection with bail out stenting during percutaneous coronary intervention. Bansal NO, Shivapuje SK. Indian Heart J; 2013 Dec 12; 65(6):707-9. PubMed ID: 24407544 [No Abstract] [Full Text] [Related]
19. Coronary stenting for aortocoronary dissection following balloon angioplasty. Seifein HB, Missri JC, Warner MF. Cathet Cardiovasc Diagn; 1996 Jun 12; 38(2):222-5. PubMed ID: 8776535 [Abstract] [Full Text] [Related]