These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
294 related items for PubMed ID: 21835181
1. Evaluation of a flow cytometry method for CD4 T cell enumeration based on volumetric primary CD4 gating using thermoresistant reagents. Dieye TN, Diaw PA, Daneau G, Wade D, Sylla Niang M, Camara M, Diallo AA, Toure Kane C, Diop Ndiaye H, Mbengue B, Dieye A, Kestens L, Mboup S. J Immunol Methods; 2011 Sep 30; 372(1-2):7-13. PubMed ID: 21835181 [Abstract] [Full Text] [Related]
2. New BD FACSCount CD4 reagent system for simultaneous enumeration of percent and absolute CD4 T-lymphocytes in HIV-1-infected pediatric patients. Pattanapanyasat K, Sukapirom K, Kowawisatsut L, Thepthai C. Cytometry B Clin Cytom; 2008 Sep 30; 74 Suppl 1():S98-106. PubMed ID: 18307252 [Abstract] [Full Text] [Related]
3. Evaluation of a single-platform microcapillary flow cytometer for enumeration of absolute CD4+ T-lymphocyte counts in HIV-1 infected Thai patients. Pattanapanyasat K, Phuang-Ngern Y, Lerdwana S, Wasinrapee P, Sakulploy N, Noulsri E, Thepthai C, McNicholl JM. Cytometry B Clin Cytom; 2007 Sep 30; 72(5):387-96. PubMed ID: 17474130 [Abstract] [Full Text] [Related]
4. Absolute and percent CD4+ T-cell enumeration by flow cytometry using capillary blood. Sitoe N, Luecke E, Tembe N, Matavele R, Cumbane V, Macassa E, Vaz P, Sheppard H, Jani IV. J Immunol Methods; 2011 Sep 30; 372(1-2):1-6. PubMed ID: 21787779 [Abstract] [Full Text] [Related]
5. Evaluation of a dry format reagent alternative for CD4 T-cell enumeration for the FACSCount system: a report on a Moroccan-Canadian study. Bergeron M, Ding T, Elharti E, Oumzil H, Soucy N, Harmouche H, Chaouch S, Aouad RE, Chabot C, Mandy F. Cytometry B Clin Cytom; 2010 May 30; 78(3):188-93. PubMed ID: 19847883 [Abstract] [Full Text] [Related]
6. CD4+ T lymphocytes enumeration by an easy-to-use single platform image cytometer for HIV monitoring in resource-constrained settings. Li X, Ymeti A, Lunter B, Breukers C, Tibbe AG, Terstappen LW, Greve J. Cytometry B Clin Cytom; 2007 Sep 30; 72(5):397-407. PubMed ID: 17311352 [Abstract] [Full Text] [Related]
7. Validation of a single-platform, volumetric, flow cytometry for CD4 T cell count monitoring in therapeutic mobile unit. Mbopi-Kéou FX, Sagnia B, Ngogang J, Angwafo FF, Colizzi V, Montagnier L, Bélec L. J Transl Med; 2012 Feb 06; 10():22. PubMed ID: 22309994 [Abstract] [Full Text] [Related]
8. Enumeration of the absolute CD4 T-lymphocyte count by cell-bead assay. Nantakomol D, Nuchnoi P, Noulsri E, Lerdwana S, Krisin S, Chanprasert S, Pattanapanyasat K. Cytometry B Clin Cytom; 2010 Jul 06; 78(4):260-6. PubMed ID: 20309993 [Abstract] [Full Text] [Related]
9. CD45-assisted PanLeucogating for accurate, cost-effective dual-platform CD4+ T-cell enumeration. Glencross D, Scott LE, Jani IV, Barnett D, Janossy G. Cytometry; 2002 Apr 15; 50(2):69-77. PubMed ID: 12116348 [Abstract] [Full Text] [Related]
10. Validation of a single-platform, volumetric, CD45-assisted PanLeucogating Auto40 flow cytometer to determine the absolute number and percentages of CD4 T cells in resource-constrained settings using Cameroonian patients' samples. Mbopi-Kéou FX, Mion S, Sagnia B, Bélec L. Clin Vaccine Immunol; 2012 Apr 15; 19(4):609-15. PubMed ID: 22336291 [Abstract] [Full Text] [Related]
11. CD4+ T-lymphocyte enumeration with a flow-rate based method in three flow cytometers with different years in service. Pattanapanyasat K, Chimma P, Sratongno P, Lerdwana S. Cytometry B Clin Cytom; 2008 Sep 15; 74(5):310-8. PubMed ID: 18481294 [Abstract] [Full Text] [Related]
12. A simplified flow cytometry method of CD4 and CD8 cell counting based on thermoresistant reagents: implications for large scale monitoring of HIV-infected patients in resource-limited settings. Barbesti S, Soldini L, Carcelain G, Guignet A, Colizzi V, Mantelli B, Corvaglia A, Tran-Minh T, Dorigatti F, Autran B, Lazzarin A, Beretta A. Cytometry B Clin Cytom; 2005 Nov 15; 68(1):43-51. PubMed ID: 16184613 [Abstract] [Full Text] [Related]
13. Single-platform, volumetric, CD45-assisted pan-leucogating flow cytometry for CD4 T lymphocytes monitoring of HIV infection according to the WHO recommendations for resource-constrained settings. Koyalta D, Jenabian MA, Nadjiouroum N, Djouater B, Djemadji-Oudjeil N, Ndjoyi-Mbiguino A, Bélec L. BMC Res Notes; 2013 Apr 30; 6():169. PubMed ID: 23631664 [Abstract] [Full Text] [Related]
14. A multicenter evaluation of the PanLeucogating method and the use of generic monoclonal antibody reagents for CD4 enumeration in HIV-infected patients in Thailand. Pattanapanyasat K, Shain H, Noulsri E, Lerdwana S, Thepthai C, Prasertsilpa V, Likanonsakul S, Yothipitak P, Nookhai S, Eksaengsri A. Cytometry B Clin Cytom; 2005 May 30; 65(1):29-36. PubMed ID: 15800883 [Abstract] [Full Text] [Related]
15. Performance of the Panleucogating protocol for CD4+ T cell enumeration in an HIV dedicated laboratory facility in Barbados. Sippy-Chatrani N, Marshall S, Branch S, Carmichael-Simmons K, Landis RC, Abayomi A. Cytometry B Clin Cytom; 2008 May 30; 74 Suppl 1():S65-8. PubMed ID: 18228556 [Abstract] [Full Text] [Related]
16. Simplified volumetric flow cytometry allows feasible and accurate determination of CD4 T lymphocytes in immunodeficient patients worldwide. Cassens U, Göhde W, Kuling G, Gröning A, Schlenke P, Lehman LG, Traoré Y, Servais J, Henin Y, Reichelt D, Greve B. Antivir Ther; 2004 Jun 30; 9(3):395-405. PubMed ID: 15259902 [Abstract] [Full Text] [Related]
17. Evaluation of four alternative methodologies for determination of absolute CD4+ lymphocyte counts. The National Heart, Lung, and Blood Institute Retrovirus Epidemiology Donor Study. Johnson D, Hirschkorn D, Busch MP. J Acquir Immune Defic Syndr Hum Retrovirol; 1995 Dec 15; 10(5):522-30. PubMed ID: 8548331 [Abstract] [Full Text] [Related]
18. Perfect count: a novel approach for the single platform enumeration of absolute CD4+ T-lymphocytes. Storie I, Sawle A, Goodfellow K, Whitby L, Granger V, Ward RY, Peel J, Smart T, Reilly JT, Barnett D. Cytometry B Clin Cytom; 2004 Jan 15; 57(1):47-52. PubMed ID: 14696063 [Abstract] [Full Text] [Related]
19. Panleucogating as an accurate and affordable flow cytometric protocol to analyse lymphocyte subsets among HIV-positive patients on HAART treatment in Mozambique. Ceffa S, Erba F, Assane M, Coelho E, Calgaro M, Brando B. J Biol Regul Homeost Agents; 2005 Jan 15; 19(3-4):169-75. PubMed ID: 16602633 [Abstract] [Full Text] [Related]
20. Performance of the BD FACSPresto near to patient analyzer in comparison with representative conventional CD4 instruments in Cameroon. Sagnia B, Mbakop Ghomsi F, Gutierrez A, Sosso S, Kamgaing R, Nanfack AJ, Nji N, Ambada G, Lissom A, Tchouangueu TF, Ngu Ndengkoh L, Domkam I, Nchinda G, Ndjolo A. AIDS Res Ther; 2020 Aug 17; 17(1):53. PubMed ID: 32799909 [Abstract] [Full Text] [Related] Page: [Next] [New Search]