2. Effect of corneal stiffening on Goldmann applanation tonometry and Tono-Pen measurements in canine eyes. Tang J, Pan X, Weber PA, Liu J. Invest Ophthalmol Vis Sci; 2012 Mar 15; 53(3):1397-405. PubMed ID: 22297494 [Abstract] [Full Text] [Related]
3. Comparison of Scleral Tono-Pen Intraocular Pressure Measurements with Goldmann Applanation Tonometry. Badakere SV, Choudhari NS, Rao HL, Chary CR, Garudadri CS, Senthil S. Optom Vis Sci; 2018 Feb 15; 95(2):129-135. PubMed ID: 29370020 [Abstract] [Full Text] [Related]
4. Tono-Pen versus Goldmann Applanation Tonometry: A Comparison of 898 Eyes. Bao B, Diaconita V, Schulz DC, Hutnik C. Ophthalmol Glaucoma; 2019 Feb 15; 2(6):435-439. PubMed ID: 32672578 [Abstract] [Full Text] [Related]
5. The impact of corneal edema on intraocular pressure measurements using goldmann applanation tonometry, Tono-Pen XL, iCare, and ORA: an in vitro model. Neuburger M, Maier P, Böhringer D, Reinhard T, F Jordan J. J Glaucoma; 2013 Sep 15; 22(7):584-90. PubMed ID: 22366704 [Abstract] [Full Text] [Related]
6. The influence of central corneal thickness and age on intraocular pressure measured by pneumotonometry, non-contact tonometry, the Tono-Pen XL, and Goldmann applanation tonometry. Tonnu PA, Ho T, Newson T, El Sheikh A, Sharma K, White E, Bunce C, Garway-Heath D. Br J Ophthalmol; 2005 Jul 15; 89(7):851-4. PubMed ID: 15965165 [Abstract] [Full Text] [Related]
7. Variations of Intraocular Pressure Measured by Goldmann Applanation Tonometer, Tono-Pen, iCare Rebound Tonometer, and Pascal Dynamic Contour Tonometer in Patients With Corneal Edema After Phacoemulsification. Kiddee W, Tanjana A. J Glaucoma; 2021 Apr 01; 30(4):317-324. PubMed ID: 33137014 [Abstract] [Full Text] [Related]
8. Tono-Pen versus Goldmann tonometry after excimer laser photorefractive keratectomy. Levy Y, Zadok D, Glovinsky Y, Krakowski D, Nemet P. J Cataract Refract Surg; 1999 Apr 01; 25(4):486-91. PubMed ID: 10198852 [Abstract] [Full Text] [Related]
9. Comparison of two handheld applanation tonometers and the association of central corneal thickness, age, and intraocular pressure in normal and diseased canine eyes. Kato K. Vet Ophthalmol; 2014 Nov 01; 17(6):417-25. PubMed ID: 24517734 [Abstract] [Full Text] [Related]
13. The difference in intraocular pressure readings between 3 applanation tonometers is independent of central corneal thickness, in glaucomatous and nonglaucomatous eyes. Baily C, Dooley I, Collins N, Hickey-Dwyer M. J Glaucoma; 2014 Dec 01; 23(9):620-3. PubMed ID: 23429625 [Abstract] [Full Text] [Related]
15. Comparison of the iCare, Tono-Pen, non-contact airpuff, and Goldmann applanation tonometers in eyes with corneal edema after penetrating keratoplasty. Yeh SJ, Chen KH, Kuang TM, Liu CJ, Chen MJ. J Chin Med Assoc; 2021 Mar 01; 84(3):320-325. PubMed ID: 33587519 [Abstract] [Full Text] [Related]
16. Comparisons of intraocular pressure measurements: Goldmann applanation tonometry, noncontact tonometry, Tono-Pen tonometry, and dynamic contour tonometry. Hsu SY, Sheu MM, Hsu AH, Wu KY, Yeh JI, Tien JN, Tsai RK. Eye (Lond); 2009 Jul 01; 23(7):1582-8. PubMed ID: 19407845 [Abstract] [Full Text] [Related]
17. Accuracy of dynamic contour tonometry, Goldmann applanation tonometry, and Tono-Pen XL in edematous corneas. Kontadakis GA, Pennos A, Pentari I, Kymionis GD, Pallikaris IG, Ginis H. Ther Adv Ophthalmol; 2020 Jul 01; 12():2515841420923190. PubMed ID: 32577607 [Abstract] [Full Text] [Related]
18. A comparison of four methods of tonometry: method agreement and interobserver variability. Tonnu PA, Ho T, Sharma K, White E, Bunce C, Garway-Heath D. Br J Ophthalmol; 2005 Jul 01; 89(7):847-50. PubMed ID: 15965164 [Abstract] [Full Text] [Related]