These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
3. Influence of microgap location and configuration on the periimplant bone morphology in submerged implants. An experimental study in dogs. Weng D, Nagata MJ, Bell M, Bosco AF, de Melo LG, Richter EJ. Clin Oral Implants Res; 2008 Nov; 19(11):1141-7. PubMed ID: 18983317 [Abstract] [Full Text] [Related]
4. Influence of the size of the microgap on crestal bone levels in non-submerged dental implants: a radiographic study in the canine mandible. King GN, Hermann JS, Schoolfield JD, Buser D, Cochran DL. J Periodontol; 2002 Oct; 73(10):1111-7. PubMed ID: 12416767 [Abstract] [Full Text] [Related]
7. Crestal bone changes around titanium implants. A histometric evaluation of unloaded non-submerged and submerged implants in the canine mandible. Hermann JS, Buser D, Schenk RK, Cochran DL. J Periodontol; 2000 Sep; 71(9):1412-24. PubMed ID: 11022770 [Abstract] [Full Text] [Related]
9. The influence of non-matching implant and abutment diameters on radiographic crestal bone levels in dogs. Jung RE, Jones AA, Higginbottom FL, Wilson TG, Schoolfield J, Buser D, Hämmerle CH, Cochran DL. J Periodontol; 2008 Feb; 79(2):260-70. PubMed ID: 18251640 [Abstract] [Full Text] [Related]
11. Influence of the size of the microgap on crestal bone changes around titanium implants. A histometric evaluation of unloaded non-submerged implants in the canine mandible. Hermann JS, Schoolfield JD, Schenk RK, Buser D, Cochran DL. J Periodontol; 2001 Oct; 72(10):1372-83. PubMed ID: 11699479 [Abstract] [Full Text] [Related]
13. Crestal bone loss related to immediate implants in crestal and subcrestal position: a pilot study in dogs. Calvo-Guirado JL, López-López PJ, Mate Sanchez JE, Gargallo Albiol J, Velasco Ortega E, Delgado Ruiz R. Clin Oral Implants Res; 2014 Nov; 25(11):1286-1294. PubMed ID: 24118345 [Abstract] [Full Text] [Related]
14. Bone reactions to longstanding functional load at implants: an experimental study in dogs. Berglundh T, Abrahamsson I, Lindhe J. J Clin Periodontol; 2005 Sep; 32(9):925-32. PubMed ID: 16104954 [Abstract] [Full Text] [Related]
17. Radiographic evaluation of marginal bone level around internal-hex implants with switched platform: a clinical case report series. de Almeida FD, Carvalho AC, Fontes M, Pedrosa A, Costa R, Noleto JW, Mourão CF. Int J Oral Maxillofac Implants; 2011 Sep; 26(3):587-92. PubMed ID: 21691606 [Abstract] [Full Text] [Related]
19. Influences of microgap and micromotion of implant-abutment interface on marginal bone loss around implant neck. Liu Y, Wang J. Arch Oral Biol; 2017 Nov; 83():153-160. PubMed ID: 28780384 [Abstract] [Full Text] [Related]
20. Retrospective evaluation of crestal bone changes around implants with reduced abutment diameter placed non-submerged and at subcrestal positions: the effect of bone grafting at implant placement. Koutouzis T, Fetner M, Fetner A, Lundgren T. J Periodontol; 2011 Feb; 82(2):234-42. PubMed ID: 20731584 [Abstract] [Full Text] [Related] Page: [Next] [New Search]