These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
265 related items for PubMed ID: 21999185
1. Which is the best anticoagulant for whole blood aggregometry platelet function testing? Comparison of six anticoagulants and diverse storage conditions. Kaiser AF, Neubauer H, Franken CC, Krüger JC, Mügge A, Meves SH. Platelets; 2012; 23(5):359-67. PubMed ID: 21999185 [Abstract] [Full Text] [Related]
2. BAPA, a synthetic dual inhibitor of Factor Xa and Thrombin, extends the storage-time to a maximum of 12 hours in ADP- and 24 hours in arachidonic acid-induced impedance aggregometry. Kaiser AF, Endres HG, Mügge A, Neubauer H. Scand J Clin Lab Invest; 2011 May; 71(3):253-6. PubMed ID: 21348786 [Abstract] [Full Text] [Related]
3. Platelet function testing in hirudin and BAPA anticoagulated blood. Mani H, Hellis M, Lindhoff-Last E. Clin Chem Lab Med; 2011 Mar; 49(3):501-7. PubMed ID: 21175382 [Abstract] [Full Text] [Related]
4. Measurement of platelet function in dogs using a novel impedance aggregometer. Kalbantner K, Baumgarten A, Mischke R. Vet J; 2010 Aug; 185(2):144-51. PubMed ID: 19879171 [Abstract] [Full Text] [Related]
5. Effect of different anticoagulants on multiple electrode platelet aggregometry after clopidogrel and aspirin administration in patients undergoing coronary stent implantation: a comparison between citrate and hirudin. Zhang HZ, Yu LH, Kim MH. Platelets; 2013 Aug; 24(5):339-47. PubMed ID: 22774770 [Abstract] [Full Text] [Related]
8. Multiple electrode aggregometry: a new device to measure platelet aggregation in whole blood. Tóth O, Calatzis A, Penz S, Losonczy H, Siess W. Thromb Haemost; 2006 Dec; 96(6):781-8. PubMed ID: 17139373 [Abstract] [Full Text] [Related]
9. Assessment of Multiplate platelet aggregometry using citrate, heparin or hirudin in Rhesus macaques. Dugan G, O'Donnell L, Hanbury DB, Cline JM, Caudell DL. Platelets; 2015 Dec; 26(8):730-5. PubMed ID: 25549285 [Abstract] [Full Text] [Related]
10. Preservation of in vitro function of platelets stored in the presence of a synthetic dual inhibitor of factor Xa and thrombin. Hellstern P, Stürzebecher U, Wuchold B, Haubelt H, Seyfert UT, Bauer M, Vogt A, Stürzebecher J. J Thromb Haemost; 2007 Oct; 5(10):2119-26. PubMed ID: 17666019 [Abstract] [Full Text] [Related]
11. Preservation of platelet aggregation and dense granule secretion during extended storage of blood samples in the presence of a synthetic dual inhibitor of factor Xa and thrombin. Haubelt H, Vogt A, Hellstern P. Platelets; 2008 Nov; 19(7):496-501. PubMed ID: 18979361 [Abstract] [Full Text] [Related]
12. Influence of different anticoagulants on platelet aggregation in whole blood; a comparison between citrate, low molecular mass heparin and hirudin. Wallén NH, Ladjevardi M, Albert J, Bröijersén A. Thromb Res; 1997 Jul 01; 87(1):151-7. PubMed ID: 9253810 [Abstract] [Full Text] [Related]
13. Methodological considerations for the assessment of ADP induced platelet aggregation using the Multiplate® analyser. Johnston LR, Larsen PD, La Flamme AC, Harding SA. Platelets; 2013 Jul 01; 24(4):303-7. PubMed ID: 22686487 [Abstract] [Full Text] [Related]
14. Optimization of Multiplate(®) whole blood platelet aggregometry in the Beagle dog and Wistar rat for ex vivo drug toxicity testing. Defontis M, Côté S, Stirn M, Ledieu D. Exp Toxicol Pathol; 2013 Jul 01; 65(5):637-44. PubMed ID: 22884258 [Abstract] [Full Text] [Related]
15. Evaluation of the INNOVANCE PFA P2Y test cartridge: sensitivity to P2Y(12) blockade and influence of anticoagulant. Edwards A, Jakubowski JA, Rechner AR, Sugidachi A, Harrison P. Platelets; 2012 Jul 01; 23(2):106-15. PubMed ID: 21848368 [Abstract] [Full Text] [Related]
16. Monitoring ASA and P2Y12-specific platelet inhibition--comparison of conventional (single) and multiple electrode aggregometry. Krüger JC, Meves SH, Kara K, Mügge A, Neubauer H. Scand J Clin Lab Invest; 2014 Oct 01; 74(7):568-74. PubMed ID: 25296945 [Abstract] [Full Text] [Related]
17. [Effects of anticoagulants and storage temperature on immature platelet fraction % (IPF%) values in stored samples measured by the automated hematology analyzer, XE-5000--utility of CTAD-anticoagulation and room temperature storage]. Nishiyama M, Hayashi S, Kabutomori O, Yamanishi H, Suehisa E, Kurata Y, Kashiwagi H, Tomiyama Y. Rinsho Byori; 2011 May 01; 59(5):452-8. PubMed ID: 21706858 [Abstract] [Full Text] [Related]
18. Hirudin versus citrate as an anticoagulant for ROTEM platelet whole blood impedance aggregometry in thrombocytopenic patients. Wickramasinghe W, Alvitigala BY, Perera T, Karunanayake P, Jayasinghe S, Rajapakse S, Weeratunga P, Wijewickrama A, Arya R, Goerlinger K, Gooneratne LV. Platelets; 2023 Dec 01; 34(1):2229909. PubMed ID: 37370234 [Abstract] [Full Text] [Related]
19. Effects of storage on in vitro platelet responses: comparison of ACD and Na citrate anticoagulated samples. Pignatelli P, Pulcinelli FM, Ciatti F, Pesciotti M, Ferroni P, Gazzaniga PP. J Clin Lab Anal; 1996 Dec 01; 10(3):134-9. PubMed ID: 8731500 [Abstract] [Full Text] [Related]
20. Sampling conditions influence multiple electrode platelet aggregometry in cardiac surgery patients. Karlsson M, Roman-Emanuel C, Thimour-Bergström L, Hakimi CS, Jeppsson A. Scand Cardiovasc J; 2013 Apr 01; 47(2):98-103. PubMed ID: 23098207 [Abstract] [Full Text] [Related] Page: [Next] [New Search]