These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
3251 related items for PubMed ID: 22027737
1. A prospective randomised study using optical coherence tomography to assess endothelial coverage and neointimal proliferation at 6-months after implantation of a coronary everolimus-eluting stent compared with a bare metal stent postdilated with a paclitaxel-eluting balloon (OCTOPUS Trial): rationale, design and methods. Poerner TC, Otto S, Gassdorf J, Janiak F, Danzer C, Ferrari M, Figulla HR. EuroIntervention; 2011 May; 7 Suppl K():K93-9. PubMed ID: 22027737 [Abstract] [Full Text] [Related]
2. Stent coverage and neointimal proliferation in bare metal stents postdilated with a Paclitaxel-eluting balloon versus everolimus-eluting stents: prospective randomized study using optical coherence tomography at 6-month follow-up. Poerner TC, Otto S, Gassdorf J, Nitsche K, Janiak F, Scheller B, Goebel B, Jung C, Figulla HR. Circ Cardiovasc Interv; 2014 Dec; 7(6):760-7. PubMed ID: 25371536 [Abstract] [Full Text] [Related]
3. Optical coherence tomography (OCT) in PCI for in-stent restenosis (ISR): rationale and design of the SEDUCE (Safety and Efficacy of a Drug elUting balloon in Coronary artery rEstenosis) study. Adriaenssens T, Dens J, Ughi G, Coosemans M, Onsea K, Dubois C, Sinnaeve P, Vrolix M, Desmet W. EuroIntervention; 2011 May; 7 Suppl K():K100-5. PubMed ID: 22027717 [Abstract] [Full Text] [Related]
11. Comparative analysis of neointimal coverage with paclitaxel and zotarolimus drug-eluting stents, using optical coherence tomography 6 months after implantation. Motreff P, Souteyrand G, Levesque S, Ouchchane L, Dauphin C, Sarry L, Cassagnes J, Lusson JR. Arch Cardiovasc Dis; 2009 Jan; 102(8-9):617-24. PubMed ID: 19786265 [Abstract] [Full Text] [Related]
12. First-in-human evaluation of a bioabsorbable polymer-coated sirolimus-eluting stent: imaging and clinical results of the DESSOLVE I Trial (DES with sirolimus and a bioabsorbable polymer for the treatment of patients with de novo lesion in the native coronary arteries). Ormiston J, Webster M, Stewart J, Vrolix M, Whitbourn R, Donohoe D, Knape C, Lansky A, Attizzani GF, Fitzgerald P, Kandzari DE, Wijns W. JACC Cardiovasc Interv; 2013 Oct; 6(10):1026-34. PubMed ID: 24055443 [Abstract] [Full Text] [Related]
13. Neointimal coverage on drug-eluting stent struts crossing side-branch vessels using optical coherence tomography. Her AY, Lee BK, Shim JM, Kim JS, Kim BK, Ko YG, Choi D, Jang Y, Hong MK. Am J Cardiol; 2010 Jun 01; 105(11):1565-9. PubMed ID: 20494663 [Abstract] [Full Text] [Related]
14. In-stent restenosis: the gold standard has changed. Chin K. EuroIntervention; 2011 May 01; 7 Suppl K():K43-6. PubMed ID: 22027726 [Abstract] [Full Text] [Related]
18. [Visualization of intimal proliferation of drug-eluting stent and bare mental stent by use of optical coherence tomography]. Chen BX, Ma FY, Luo W, Xie WL, Sun SH, Guo XM, Wang F, Zhao XZ, Chu XW. Zhonghua Yi Xue Za Zhi; 2006 Apr 25; 86(16):1102-6. PubMed ID: 16796834 [Abstract] [Full Text] [Related]
19. Influence of a paclitaxel coated balloon in combination with a bare metal stent on restenosis and endothelial function: comparison with a drug eluting stent and a bare metal stent. Clever YP, Cremers B, Speck U, Dietz U, Böhm M, Scheller B. Catheter Cardiovasc Interv; 2014 Aug 01; 84(2):323-31. PubMed ID: 23996969 [Abstract] [Full Text] [Related]