These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
10. Assessment of changes in cardiac index with calibrated pulse contour analysis in cardiac surgery: A prospective observational study. Fischer MO, Rebet O, Guinot PG, Lemétayer C, Saplacan V, Gérard JL, Fellahi JL, Hanouz JL, Lorne E, French Hemodynamic Team. Anaesth Crit Care Pain Med; 2016 Aug; 35(4):261-7. PubMed ID: 27083307 [Abstract] [Full Text] [Related]
11. Cardiac index monitoring by pulse contour analysis and thermodilution after pediatric cardiac surgery. Fakler U, Pauli Ch, Balling G, Lorenz HP, Eicken A, Hennig M, Hess J. J Thorac Cardiovasc Surg; 2007 Jan; 133(1):224-8. PubMed ID: 17198817 [Abstract] [Full Text] [Related]
12. Nurse-determined assessment of cardiac output. Comparing a non-invasive cardiac output device and pulmonary artery catheter: a prospective observational study. Corley A, Barnett AG, Mullany D, Fraser JF. Int J Nurs Stud; 2009 Oct; 46(10):1291-7. PubMed ID: 19423107 [Abstract] [Full Text] [Related]
13. Agreement of cardiac output measurement between pulse contour analysis and thermodilution in various body positions: a porcine study. Shih PC, Hung YC, Chen YL, Tsai HJ, Chen CY, Huang CJ. J Surg Res; 2013 May; 181(2):315-22. PubMed ID: 22884452 [Abstract] [Full Text] [Related]
15. [Comparison of ICG thoracic bioimpedance cardiac output monitoring system in patients undergoing cardiac surgery with pulmonary artery cardiac output measurements]. Simon R, Desebbe O, Hénaine R, Bastien O, Lehot JJ, Cannesson M. Ann Fr Anesth Reanim; 2009 Jun; 28(6):537-41. PubMed ID: 19525086 [Abstract] [Full Text] [Related]
16. Transoesophageal echocardiography accurately detects cardiac output variation: a prospective comparison with thermodilution in cardiac surgery. Parra V, Fita G, Rovira I, Matute P, Gomar C, Paré C. Eur J Anaesthesiol; 2008 Feb; 25(2):135-43. PubMed ID: 17672920 [Abstract] [Full Text] [Related]
17. Accuracy of cardiac output measurements with pulse contour analysis (PulseCO) and Doppler echocardiography during off-pump coronary artery bypass grafting. Missant C, Rex S, Wouters PF. Eur J Anaesthesiol; 2008 Mar; 25(3):243-8. PubMed ID: 17996125 [Abstract] [Full Text] [Related]
18. An uncalibrated pulse contour method to measure cardiac output during aortic counterpulsation. Scolletta S, Franchi F, Taccone FS, Donadello K, Biagioli B, Vincent JL. Anesth Analg; 2011 Dec; 113(6):1389-95. PubMed ID: 22003226 [Abstract] [Full Text] [Related]
19. Unreliability of pulse contour-derived cardiac output in piglets simulating acute hemorrhagic shock and rapid volume expansion. Lee CH, Wang JY, Huang KL, Chiu HW, Fei TC, Chen TS, Chang H. J Trauma; 2010 Jun; 68(6):1357-61. PubMed ID: 20539180 [Abstract] [Full Text] [Related]
20. Effects of extravascular lung water on the measurement of transpulmonary thermodilution cardiac output in acute respiratory distress syndrome patients. Huang CC, Kao KC, Fu JY, Hsieh MJ. J Cardiothorac Vasc Anesth; 2011 Jun; 25(3):481-5. PubMed ID: 20829067 [Abstract] [Full Text] [Related] Page: [Next] [New Search]