These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
2. Clinical Experience of Vibroplasty With Direct Coupling to the Oval Window Without Use of a Coupler. Kwak SH, Moon YM, Nam GS, Bae SH, Kim SH, Jung J, Choi JY. Laryngoscope; 2020 Dec; 130(12):E926-E932. PubMed ID: 31977072 [Abstract] [Full Text] [Related]
3. Reinforced active middle ear implant fixation in incus vibroplasty. Mlynski R, Dalhoff E, Heyd A, Wildenstein D, Hagen R, Gummer AW, Schraven SP. Ear Hear; 2015 Jan; 36(1):72-81. PubMed ID: 25099400 [Abstract] [Full Text] [Related]
4. A comparative study of MED-EL FMT attachment to the long process of the incus in intact middle ears and its attachment to disarticulated stapes head. Chen T, Ren LJ, Yin DM, Li J, Yang L, Dai PD, Zhang TY. Hear Res; 2017 Sep; 353():97-103. PubMed ID: 28666703 [Abstract] [Full Text] [Related]
5. A new vibroplasty coupling technique as a treatment for conductive and mixed hearing losses: a report of 4 cases. Huber AM, Mlynski R, Müller J, Dillier N, Holzmann D, Wolframm MD, Hagen R. Otol Neurotol; 2012 Jun; 33(4):613-7. PubMed ID: 22429947 [Abstract] [Full Text] [Related]
6. Do we really need a Coupler for the round window application of an AMEI? Schwab B, Grigoleit S, Teschner M. Otol Neurotol; 2013 Sep; 34(7):1181-5. PubMed ID: 23921921 [Abstract] [Full Text] [Related]
7. Clip vibroplasty: experimental evaluation and first clinical results. Hüttenbrink KB, Beutner D, Bornitz M, Luers JC, Zahnert T. Otol Neurotol; 2011 Jun; 32(4):650-3. PubMed ID: 21765388 [Abstract] [Full Text] [Related]
8. Electrocochleography in round window Vibrant Soundbridge implantation. Colletti V, Mandalà M, Colletti L. Otolaryngol Head Neck Surg; 2012 Apr; 146(4):633-40. PubMed ID: 22140205 [Abstract] [Full Text] [Related]
9. A retrospective European multicenter analysis of the functional outcomes after active middle ear implant surgery using the third generation vibroplasty couplers. Rahne T, Skarzynski PH, Hagen R, Radeloff A, Lassaletta L, Barbara M, Plontke SK, Mlynski R. Eur Arch Otorhinolaryngol; 2021 Jan; 278(1):67-75. PubMed ID: 32451668 [Abstract] [Full Text] [Related]
10. Influence of the Coupling on the Hearing Outcome After Implantation of an Active Middle Ear Implant: Comparison of the Transmission Behavior in Temporal Bone Experiments With Clinical Data. Müller C, Lailach S, Bornitz M, Lasurashvili N, Essinger TM, Neudert M, Zahnert T. Ear Hear; 2021 Jan; 44(1):135-145. PubMed ID: 35913925 [Abstract] [Full Text] [Related]
11. Oval window membrane vibroplasty for direct acoustic cochlear stimulation: treating severe mixed hearing loss in challenging middle ears. Schwab B, Salcher RB, Maier H, Kontorinis G. Otol Neurotol; 2012 Jul; 33(5):804-9. PubMed ID: 22699990 [Abstract] [Full Text] [Related]
12. Presentation of floating mass transducer and Vibroplasty couplers on CT and cone beam CT. Mlynski R, Nguyen TD, Plontke SK, Kösling S. Eur Arch Otorhinolaryngol; 2014 Apr; 271(4):665-72. PubMed ID: 23529745 [Abstract] [Full Text] [Related]
13. Vibrant Soundbridge for hearing restoration after chronic ear surgery. Streitberger C, Perotti M, Beltrame MA, Giarbini N. Rev Laryngol Otol Rhinol (Bord); 2009 Apr; 130(2):83-8. PubMed ID: 19813469 [Abstract] [Full Text] [Related]
14. A New Stapes-Head Coupler for the Vibrant Soundbridge System. Warnholtz B, Schär M, Cuny P, Sonntag K, Beutner D, Dobrev I, Röösli C, Sim JH. Audiol Neurootol; 2021 Apr; 26(4):287-294. PubMed ID: 33647905 [Abstract] [Full Text] [Related]
15. Vibroplasty in mixed and conductive hearing loss: comparison of different coupling methods. Vyskocil E, Riss D, Honeder C, Arnoldner C, Hamzavi JS, Baumgartner WD, Flak S, Gstoettner W. Laryngoscope; 2014 Jun; 124(6):1436-43. PubMed ID: 24338550 [Abstract] [Full Text] [Related]
16. Coupling of an active middle-ear implant to the long process of the incus using an elastic clip attachment. Schraven SP, Mlynski R, Dalhoff E, Heyd A, Wildenstein D, Rak K, Radeloff A, Hagen R, Gummer AW. Hear Res; 2016 Oct; 340():179-184. PubMed ID: 27037037 [Abstract] [Full Text] [Related]
17. Long-Term Outcomes of Vibroplasty Coupler Implantations to Treat Mixed/Conductive Hearing Loss. Zahnert T, Mlynski R, Löwenheim H, Beutner D, Hagen R, Ernst A, Zehlicke T, Kühne H, Friese N, Tropitzsch A, Luers JC, Todt I, Hüttenbrink KB. Audiol Neurootol; 2018 Oct; 23(6):316-325. PubMed ID: 30650421 [Abstract] [Full Text] [Related]
18. Functional results of Vibrant Soundbridge middle ear implants in conductive and mixed hearing losses. Bernardeschi D, Hoffman C, Benchaa T, Labassi S, Beliaeff M, Sterkers O, Grayeli AB. Audiol Neurootol; 2011 Oct; 16(6):381-7. PubMed ID: 21228566 [Abstract] [Full Text] [Related]
19. Comparison of Alternative Coupling Methods of the Vibrant Soundbridge Floating Mass Transducer. Busch S, Lenarz T, Maier H. Audiol Neurootol; 2016 Oct; 21(6):347-355. PubMed ID: 28068651 [Abstract] [Full Text] [Related]
20. Long-term Outcomes of Clip Coupler Implantation in Patients with Unilateral Congenital Aural Atresia. Zhao C, Yang J, Liu Y, Gao M, Chen P, Zhao S. Ann Otol Rhinol Laryngol; 2020 Dec; 129(12):1221-1228. PubMed ID: 32500728 [Abstract] [Full Text] [Related] Page: [Next] [New Search]