These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


369 related items for PubMed ID: 22072260

  • 1. Surgical trauma after sequential insertion of intracochlear catheters and electrode arrays (a histologic study).
    Ibrahim HN, Helbig S, Bossard D, Truy E.
    Otol Neurotol; 2011 Dec; 32(9):1448-54. PubMed ID: 22072260
    [Abstract] [Full Text] [Related]

  • 2. [Evaluation of the insertion-trauma of the Nucleus Contour Advance electrode-array in a human temporal bone model].
    Klenzner T, Richter B, Nagursky H, Schipper J, Laszig R, Aschendorff A.
    Laryngorhinootologie; 2004 Dec; 83(12):840-4. PubMed ID: 15611904
    [Abstract] [Full Text] [Related]

  • 3. Combining perimodiolar electrode placement and atraumatic insertion properties in cochlear implantation -- fact or fantasy?
    Adunka OF, Pillsbury HC, Kiefer J.
    Acta Otolaryngol; 2006 May; 126(5):475-82. PubMed ID: 16698696
    [Abstract] [Full Text] [Related]

  • 4. The internal dimensions of the cochlear scalae with special reference to cochlear electrode insertion trauma.
    Biedron S, Prescher A, Ilgner J, Westhofen M.
    Otol Neurotol; 2010 Jul; 31(5):731-7. PubMed ID: 20142798
    [Abstract] [Full Text] [Related]

  • 5.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 6. Impact of electrode insertion depth on intracochlear trauma.
    Adunka O, Kiefer J.
    Otolaryngol Head Neck Surg; 2006 Sep; 135(3):374-82. PubMed ID: 16949967
    [Abstract] [Full Text] [Related]

  • 7. Evaluating cochlear implant trauma to the scala vestibuli.
    Adunka O, Kiefer J, Unkelbach MH, Radeloff A, Gstoettner W.
    Clin Otolaryngol; 2005 Apr; 30(2):121-7. PubMed ID: 15839863
    [Abstract] [Full Text] [Related]

  • 8.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 9. Cochlear implantation via the round window membrane minimizes trauma to cochlear structures: a histologically controlled insertion study.
    Adunka O, Unkelbach MH, Mack M, Hambek M, Gstoettner W, Kiefer J.
    Acta Otolaryngol; 2004 Sep; 124(7):807-12. PubMed ID: 15370564
    [Abstract] [Full Text] [Related]

  • 10. Development and evaluation of an improved cochlear implant electrode design for electric acoustic stimulation.
    Adunka O, Kiefer J, Unkelbach MH, Lehnert T, Gstoettner W.
    Laryngoscope; 2004 Jul; 114(7):1237-41. PubMed ID: 15235353
    [Abstract] [Full Text] [Related]

  • 11.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 12.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 13.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 14.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 15. Insertion trauma of a new cochlear implant electrode: evaluated by histology in fresh human temporal bone specimens.
    Du Q, Wang C, He G, Sun Z.
    Acta Otolaryngol; 2021 May; 141(5):490-494. PubMed ID: 33784954
    [Abstract] [Full Text] [Related]

  • 16. Temporal bone investigations on landmarks for conventional or endosteal insertion of cochlear electrodes.
    Pau HW, Just T, Dommerich S, Behrend D.
    Acta Otolaryngol; 2007 Sep; 127(9):920-6. PubMed ID: 17712669
    [Abstract] [Full Text] [Related]

  • 17. Variance of angular insertion depths in free-fitting and perimodiolar cochlear implant electrodes.
    Radeloff A, Mack M, Baghi M, Gstoettner WK, Adunka OF.
    Otol Neurotol; 2008 Feb; 29(2):131-6. PubMed ID: 18090204
    [Abstract] [Full Text] [Related]

  • 18.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 19.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 20.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]


    Page: [Next] [New Search]
    of 19.