These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
2. Early post-ischemic hyperemia on transcranial cerebral oxygen saturation monitoring in carotid endarterectomy is associated with severity of cerebral ischemic insult during carotid artery clamping. Kobayashi M, Ogasawara K, Suga Y, Chida K, Yoshida K, Otawara Y, Tsushima E, Ogawa A. Neurol Res; 2009 Sep; 31(7):728-33. PubMed ID: 19108754 [Abstract] [Full Text] [Related]
3. Intraoperative multimodal evoked potential monitoring during carotid endarterectomy: a retrospective study of 264 patients. Malcharek MJ, Kulpok A, Deletis V, Ulkatan S, Sablotzki A, Hennig G, Gille J, Pilge S, Schneider G. Anesth Analg; 2015 Jun; 120(6):1352-60. PubMed ID: 24977915 [Abstract] [Full Text] [Related]
5. The Relationship between Carotid Stump Pressure and Changes in Motor-Evoked Potentials in Carotid Endarterectomy Patients. Hokari M, Ito Y, Yamazaki K, Chiba Y, Isobe M, Isu T. J Neurol Surg A Cent Eur Neurosurg; 2016 Jul; 77(4):291-6. PubMed ID: 26968148 [Abstract] [Full Text] [Related]
7. Accuracy of cerebral monitoring in detecting cerebral ischemia during carotid endarterectomy: a comparison of transcranial Doppler sonography, near-infrared spectroscopy, stump pressure, and somatosensory evoked potentials. Moritz S, Kasprzak P, Arlt M, Taeger K, Metz C. Anesthesiology; 2007 Oct; 107(4):563-9. PubMed ID: 17893451 [Abstract] [Full Text] [Related]
8. Near-infrared spectroscopy can predict the onset of cerebral hyperperfusion syndrome after carotid endarterectomy. Pennekamp CW, Immink RV, den Ruijter HM, Kappelle LJ, Ferrier CM, Bots ML, Buhre WF, Moll FL, de Borst GJ. Cerebrovasc Dis; 2012 Oct; 34(4):314-21. PubMed ID: 23146912 [Abstract] [Full Text] [Related]
9. Good correlation between cerebral oxygenation measured using near infrared spectroscopy and stump pressure during carotid clamping. Yamamoto K, Miyata T, Nagawa H. Int Angiol; 2007 Sep; 26(3):262-5. PubMed ID: 17622209 [Abstract] [Full Text] [Related]
17. The value of near-infrared spectroscopy measured cerebral oximetry during carotid endarterectomy in perioperative stroke prevention. A review. Pennekamp CW, Bots ML, Kappelle LJ, Moll FL, de Borst GJ. Eur J Vasc Endovasc Surg; 2009 Nov; 38(5):539-45. PubMed ID: 19665397 [Abstract] [Full Text] [Related]
18. Comparison of Single and Dual Monitoring during Carotid Endarterectomy. Uno M, Yagi K, Takai H, Oyama N, Yagita Y, Hazama K, Nakatsuka H, Matsubara S. Neurol Med Chir (Tokyo); 2021 Feb 15; 61(2):124-133. PubMed ID: 33390558 [Abstract] [Full Text] [Related]