These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
194 related items for PubMed ID: 22156990
1. Is T2* enough to assess oxygenation? Quantitative blood oxygen level-dependent analysis in brain tumor. Christen T, Lemasson B, Pannetier N, Farion R, Remy C, Zaharchuk G, Barbier EL. Radiology; 2012 Feb; 262(2):495-502. PubMed ID: 22156990 [Abstract] [Full Text] [Related]
2. Fetoplacental oxygenation in an intrauterine growth restriction rat model by using blood oxygen level-dependent MR imaging at 4.7 T. Chalouhi GE, Alison M, Deloison B, Thiam R, Autret G, Balvay D, Cuenod CA, Clément O, Salomon LJ, Siauve N. Radiology; 2013 Oct; 269(1):122-9. PubMed ID: 23696681 [Abstract] [Full Text] [Related]
3. Science to practice: is t2* enough to assess oxygenation? Bryan RN. Radiology; 2012 Feb; 262(2):375-7. PubMed ID: 22282175 [Abstract] [Full Text] [Related]
4. Evaluation of the relationship between MR estimates of blood oxygen saturation and hypoxia: effect of an antiangiogenic treatment on a gliosarcoma model. Lemasson B, Christen T, Serduc R, Maisin C, Bouchet A, Le Duc G, Rémy C, Barbier EL. Radiology; 2012 Dec; 265(3):743-52. PubMed ID: 22996750 [Abstract] [Full Text] [Related]
5. Technical considerations on the validity of blood oxygenation level-dependent-based MR assessment of vascular deoxygenation. Hirsch NM, Toth V, Förschler A, Kooijman H, Zimmer C, Preibisch C. NMR Biomed; 2014 Jul; 27(7):853-62. PubMed ID: 24809665 [Abstract] [Full Text] [Related]
6. Photoacoustic imaging of vascular hemodynamics: validation with blood oxygenation level-dependent MR imaging. Rich LJ, Seshadri M. Radiology; 2015 Apr; 275(1):110-8. PubMed ID: 25423146 [Abstract] [Full Text] [Related]
7. Detailing the relation between renal T2* and renal tissue pO2 using an integrated approach of parametric magnetic resonance imaging and invasive physiological measurements. Pohlmann A, Arakelyan K, Hentschel J, Cantow K, Flemming B, Ladwig M, Waiczies S, Seeliger E, Niendorf T. Invest Radiol; 2014 Aug; 49(8):547-60. PubMed ID: 24651661 [Abstract] [Full Text] [Related]
8. Experimental MRI Monitoring of Renal Blood Volume Fraction Variations En Route to Renal Magnetic Resonance Oximetry. Pohlmann A, Cantow K, Huelnhagen T, Grosenick D, Dos Santos Periquito J, Boehmert L, Gladytz T, Waiczies S, Flemming B, Seeliger E, Niendorf T. Tomography; 2017 Dec; 3(4):188-200. PubMed ID: 30042981 [Abstract] [Full Text] [Related]
9. Probing renal blood volume with magnetic resonance imaging. Niendorf T, Seeliger E, Cantow K, Flemming B, Waiczies S, Pohlmann A. Acta Physiol (Oxf); 2020 Apr; 228(4):e13435. PubMed ID: 31876349 [Abstract] [Full Text] [Related]
10. Hypoxia imaging in brain tumors. Yetkin FZ, Mendelsohn D. Neuroimaging Clin N Am; 2002 Nov; 12(4):537-52. PubMed ID: 12687910 [Abstract] [Full Text] [Related]
11. T2-prepared velocity selective labelling: A novel idea for full-brain mapping of oxygen saturation. Alderliesten T, De Vis JB, Lemmers PMA, van Bel F, Benders MJNL, Hendrikse J, Petersen ET. Neuroimage; 2016 Oct 01; 139():65-73. PubMed ID: 27291495 [Abstract] [Full Text] [Related]
12. Comparative Analysis of Blood T2 Values Measured by T2 -TRIR and TRUST. Baas KPA, Coolen BF, Petersen ET, Biemond BJ, Strijkers GJ, Nederveen AJ. J Magn Reson Imaging; 2022 Aug 01; 56(2):516-526. PubMed ID: 35077595 [Abstract] [Full Text] [Related]
13. Correlations of noninvasive BOLD and TOLD MRI with pO2 and relevance to tumor radiation response. Hallac RR, Zhou H, Pidikiti R, Song K, Stojadinovic S, Zhao D, Solberg T, Peschke P, Mason RP. Magn Reson Med; 2014 May 01; 71(5):1863-73. PubMed ID: 23813468 [Abstract] [Full Text] [Related]
14. Effect of nitric oxide synthase inhibition on intrarenal oxygenation as evaluated by blood oxygenation level-dependent magnetic resonance imaging. Li LP, Ji L, Santos E, Dunkle E, Pierchala L, Prasad P. Invest Radiol; 2009 Feb 01; 44(2):67-73. PubMed ID: 19034027 [Abstract] [Full Text] [Related]
15. Reproducibility and relative stability in magnetic resonance imaging indices of tumor vascular physiology over a period of 24h in a rat 9L gliosarcoma model. Nagaraja TN, Elmghirbi R, Brown SL, Schultz LR, Lee IY, Keenan KA, Panda S, Cabral G, Mikkelsen T, Ewing JR. Magn Reson Imaging; 2017 Dec 01; 44():131-139. PubMed ID: 28887206 [Abstract] [Full Text] [Related]
17. Repeated assessment of orthotopic glioma pO(2) by multi-site EPR oximetry: a technique with the potential to guide therapeutic optimization by repeated measurements of oxygen. Khan N, Mupparaju S, Hou H, Williams BB, Swartz H. J Neurosci Methods; 2012 Feb 15; 204(1):111-117. PubMed ID: 22079559 [Abstract] [Full Text] [Related]
18. Gradient-echo and spin-echo blood oxygenation level-dependent functional MRI at ultrahigh fields of 9.4 and 15.2 Tesla. Han S, Son JP, Cho H, Park JY, Kim SG. Magn Reson Med; 2019 Feb 15; 81(2):1237-1246. PubMed ID: 30183108 [Abstract] [Full Text] [Related]
19. Comparison of 1H blood oxygen level-dependent (BOLD) and 19F MRI to investigate tumor oxygenation. Zhao D, Jiang L, Hahn EW, Mason RP. Magn Reson Med; 2009 Aug 15; 62(2):357-64. PubMed ID: 19526495 [Abstract] [Full Text] [Related]
20. Tissue pO2 of orthotopic 9L and C6 gliomas and tumor-specific response to radiotherapy and hyperoxygenation. Khan N, Li H, Hou H, Lariviere JP, Gladstone DJ, Demidenko E, Swartz HM. Int J Radiat Oncol Biol Phys; 2009 Mar 01; 73(3):878-85. PubMed ID: 19136221 [Abstract] [Full Text] [Related] Page: [Next] [New Search]