These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
182 related items for PubMed ID: 22176038
1. Three rhodamine-based "off-on" chemosensors with high selectivity and sensitivity for Fe3+ imaging in living cells. Yang Z, She M, Yin B, Cui J, Zhang Y, Sun W, Li J, Shi Z. J Org Chem; 2012 Jan 20; 77(2):1143-7. PubMed ID: 22176038 [Abstract] [Full Text] [Related]
2. New fluorescence probe for Fe³⁺ with bis-rhodamine and its application as a molecular logic gate. Yan F, Zheng T, Guo S, Shi D, Han Z, Zhou S, Chen L. Spectrochim Acta A Mol Biomol Spectrosc; 2015 Dec 05; 151():881-7. PubMed ID: 26184473 [Abstract] [Full Text] [Related]
3. Three colorimetric and off-on fluorescent chemosensors for Fe3+ in aqueous media. Chai M, Li M, Zhang D, Wang CC, Ye Y, Zhao Y. Luminescence; 2013 Dec 05; 28(4):557-61. PubMed ID: 23460525 [Abstract] [Full Text] [Related]
4. A new Rhodamine B-based 'on-off' chemical sensor with high selectivity and sensitivity toward Fe(3+) and its imaging in living cells. Bao X, Shi J, Nie X, Zhou B, Wang X, Zhang L, Liao H, Pang T. Bioorg Med Chem; 2014 Sep 01; 22(17):4826-35. PubMed ID: 25065941 [Abstract] [Full Text] [Related]
5. Selective off-on fluorescent chemosensor for detection of Fe3+ ions in aqueous media. Huang L, Hou F, Cheng J, Xi P, Chen F, Bai D, Zeng Z. Org Biomol Chem; 2012 Dec 28; 10(48):9634-8. PubMed ID: 23135102 [Abstract] [Full Text] [Related]
6. Two new rhodamine-based fluorescent chemosensors for Fe3+ in aqueous solution. Liu Y, Xu Z, Wang J, Zhang D, Ye Y, Zhao Y. Luminescence; 2014 Nov 28; 29(7):945-51. PubMed ID: 24700778 [Abstract] [Full Text] [Related]
7. A rhodamine-based "turn-on" fluorescent probe for Fe3+ in aqueous solution. Ji S, Meng X, Ye W, Feng Y, Sheng H, Cai Y, Liu J, Zhu X, Guo Q. Dalton Trans; 2014 Jan 28; 43(4):1583-8. PubMed ID: 24217856 [Abstract] [Full Text] [Related]
8. A fluorescent "turn-on" probe for the dual-channel detection of Hg(II) and Mg(II) and its application of imaging in living cells. Zhao Y, Zheng B, Du J, Xiao D, Yang L. Talanta; 2011 Sep 30; 85(4):2194-201. PubMed ID: 21872078 [Abstract] [Full Text] [Related]
9. FRET-based ratiometric fluorescent probes for selective Fe3+ sensing and their applications in mitochondria. Chen WD, Gong WT, Ye ZQ, Lin Y, Ning GL. Dalton Trans; 2013 Jul 28; 42(28):10093-6. PubMed ID: 23728488 [Abstract] [Full Text] [Related]
10. Rhodamine-based "turn-on" fluorescent probe with high selectivity for Fe(2+) imaging in living cells. Hou GG, Wang CH, Sun JF, Yang MZ, Lin D, Li HJ. Biochem Biophys Res Commun; 2013 Oct 04; 439(4):459-63. PubMed ID: 24025683 [Abstract] [Full Text] [Related]
11. Rhodamine-based chemosensor for Hg(2+) in aqueous solution with a broad pH range and its application in live cell imaging. Zhao Y, Sun Y, Lv X, Liu Y, Chen M, Guo W. Org Biomol Chem; 2010 Sep 21; 8(18):4143-7. PubMed ID: 20652184 [Abstract] [Full Text] [Related]
12. A Rhodamine-Benzimidazole Based Chemosensor for Fe(3+) and its Application in Living Cells. Li G, Tang J, Ding P, Ye Y. J Fluoresc; 2016 Jan 21; 26(1):155-61. PubMed ID: 26518578 [Abstract] [Full Text] [Related]
13. A dansyl-rhodamine chemosensor for Fe(III) based on off-on FRET. Piao J, Lv J, Zhou X, Zhao T, Wu X. Spectrochim Acta A Mol Biomol Spectrosc; 2014 Jul 15; 128():475-80. PubMed ID: 24682064 [Abstract] [Full Text] [Related]
14. X-ray crystallographic and photophysical properties of rhodamine-based chemosensor for Fe3+. Zhang L, Fan J, Peng X. Spectrochim Acta A Mol Biomol Spectrosc; 2009 Jul 15; 73(2):398-402. PubMed ID: 19345607 [Abstract] [Full Text] [Related]
15. Pyrazolone as a recognition site: Rhodamine 6G-based fluorescent probe for the selective recognition of Fe3+ in acetonitrile-aqueous solution. Parihar S, Boricha VP, Jadeja RN. Luminescence; 2015 Mar 15; 30(2):168-74. PubMed ID: 24898853 [Abstract] [Full Text] [Related]
16. A rhodamine chromene-based turn-on fluorescence probe for selectively imaging Cu²+ in living cell. Liu WY, Li HY, Lv HS, Zhao BX, Miao JY. Spectrochim Acta A Mol Biomol Spectrosc; 2012 Sep 15; 95():658-63. PubMed ID: 22579327 [Abstract] [Full Text] [Related]
19. A novel series colorimetric and off-on fluorescent chemosensors for Fe3+ based on rhodamine B derivative. Zhang D, Zou R, Wang M, Chai M, Wang X, Ye Y, Zhao Y. J Fluoresc; 2013 Jan 15; 23(1):13-9. PubMed ID: 22903764 [Abstract] [Full Text] [Related]