These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
1281 related items for PubMed ID: 22203537
1. Serial changes in highly sensitive troponin I assay and early diagnosis of myocardial infarction. Keller T, Zeller T, Ojeda F, Tzikas S, Lillpopp L, Sinning C, Wild P, Genth-Zotz S, Warnholtz A, Giannitsis E, Möckel M, Bickel C, Peetz D, Lackner K, Baldus S, Münzel T, Blankenberg S. JAMA; 2011 Dec 28; 306(24):2684-93. PubMed ID: 22203537 [Abstract] [Full Text] [Related]
2. The utility of presentation and 4-hour high sensitivity troponin I to rule-out acute myocardial infarction in the emergency department. Pickering JW, Young JM, George P, Aldous S, Cullen L, Greenslade JH, Richards AM, Troughton R, Ardagh M, Frampton CM, Than MP. Clin Biochem; 2015 Dec 28; 48(18):1219-24. PubMed ID: 26232285 [Abstract] [Full Text] [Related]
3. A Rational Adoption of the High Sensitive Assay for Cardiac Troponin I in Diagnostic Routine. Croce A, Brunati P, Colzani C, Terramocci R, Favero S, Bordoni G, Galli C. Dis Markers; 2017 Dec 28; 2017():4523096. PubMed ID: 28588346 [Abstract] [Full Text] [Related]
4. Short-term (90 min) diagnostic performance for acute non-ST segment elevation myocardial infarction and 30-day prognostic evaluation of a novel third-generation high sensitivity troponin I assay. Schreiber DH, Agbo C, Wu AH. Clin Biochem; 2012 Nov 28; 45(16-17):1295-301. PubMed ID: 22705845 [Abstract] [Full Text] [Related]
5. Interpretation of high sensitivity cardiac troponin I results: reference to biological variability in patients who present to the emergency room with chest pain: case report series. Wu AH. Clin Chim Acta; 2009 Mar 28; 401(1-2):170-4. PubMed ID: 19135041 [Abstract] [Full Text] [Related]
6. Prognostic performance of a high-sensitivity assay for cardiac troponin I after non-ST elevation acute coronary syndrome: Analysis from MERLIN-TIMI 36. Bonaca MP, O'Malley RG, Murphy SA, Jarolim P, Conrad MJ, Braunwald E, Sabatine MS, Morrow DA. Eur Heart J Acute Cardiovasc Care; 2015 Oct 28; 4(5):431-40. PubMed ID: 25538086 [Abstract] [Full Text] [Related]
7. Diagnostic performance of four point of care cardiac troponin I assays to rule in and rule out acute myocardial infarction. Palamalai V, Murakami MM, Apple FS. Clin Biochem; 2013 Nov 28; 46(16-17):1631-5. PubMed ID: 23850852 [Abstract] [Full Text] [Related]
8. Myocardial Infarction Can Be Safely Excluded by High-sensitivity Troponin I Testing 3 Hours After Emergency Department Presentation. Peacock WF, Christenson R, Diercks DB, Fromm C, Headden GF, Hogan CJ, Kulstad EB, LoVecchio F, Nowak RM, Schrock JW, Singer AJ, Storrow AB, Straseski J, Wu AHB, Zelinski DP. Acad Emerg Med; 2020 Aug 28; 27(8):671-680. PubMed ID: 32220124 [Abstract] [Full Text] [Related]
9. Troponin elevations only detected with a high-sensitivity assay: clinical correlations and prognostic significance. Korley FK, Schulman SP, Sokoll LJ, DeFilippis AP, Stolbach AI, Bayram JD, Saheed MO, Omron R, Fernandez C, Lwin A, Cai SS, Post WS, Jaffe AS. Acad Emerg Med; 2014 Jul 28; 21(7):727-35. PubMed ID: 25112512 [Abstract] [Full Text] [Related]
10. Sensitive troponin assays in patients with suspected acute coronary syndrome: Results from the multicenter rule out myocardial infarction using computer assisted tomography II trial. Januzzi JL, Sharma U, Zakroysky P, Truong QA, Woodard PK, Pope JH, Hauser T, Mayrhofer T, Nagurney JT, Schoenfeld D, Peacock WF, Fleg JL, Wiviott S, Pang PS, Udelson J, Hoffmann U. Am Heart J; 2015 Apr 28; 169(4):572-8.e1. PubMed ID: 25819865 [Abstract] [Full Text] [Related]
15. Comparison of high sensitivity troponin T and I assays in the diagnosis of non-ST elevation acute myocardial infarction in emergency patients with chest pain. Cullen L, Aldous S, Than M, Greenslade JH, Tate JR, George PM, Hammett CJ, Richards AM, Ungerer JP, Troughton RW, Brown AF, Flaws DF, Lamanna A, Pemberton CJ, Florkowski C, Pretorius CJ, Chu K, Parsonage WA. Clin Biochem; 2014 Apr 28; 47(6):321-6. PubMed ID: 24316100 [Abstract] [Full Text] [Related]
16. Diagnostic accuracy of the Troponin-only Manchester Acute Coronary Syndromes (T-MACS) decision aid with a point-of-care cardiac troponin assay. Alghamdi A, Reynard C, Morris N, Moss P, Jarman H, Hardy E, Harris T, Horner D, Parris R, Body R. Emerg Med J; 2020 Apr 28; 37(4):223-228. PubMed ID: 32047076 [Abstract] [Full Text] [Related]
17. Analytical and clinical characterization of a novel high-sensitivity cardiac troponin assay in a United States population. Christenson RH, Duh SH, Mullins KE, LeClair MM, Grigorov IL, Peacock WF. Clin Biochem; 2020 Sep 28; 83():28-36. PubMed ID: 32485169 [Abstract] [Full Text] [Related]
18. Normal presenting levels of high-sensitivity troponin and myocardial infarction. Hoeller R, Rubini Giménez M, Reichlin T, Twerenbold R, Zellweger C, Moehring B, Wildi K, Freese M, Stelzig C, Hartmann B, Stoll M, Mosimann T, Reiter M, Haaf P, Mueller M, Meller B, Hochgruber T, Balmelli C, Sou SM, Murray K, Freidank H, Steuer S, Minners J, Osswald S, Mueller C. Heart; 2013 Nov 28; 99(21):1567-72. PubMed ID: 23604180 [Abstract] [Full Text] [Related]