  • 26. Influence of noise on wave boundary recognition by ECG measurement programs. Recommendations for preprocessing.
    Willems JL, Zywietz C, Arnaud P, van Bemmel JH, Degani R, Macfarlane PW.
    Comput Biomed Res; 1987 Dec; 20(6):543-62. PubMed ID: 3319381
    [Abstract] [Full Text] [Related]

  • 27. Computer-assisted instruction of arrhythmia for MS-windows.
    Takeuchi A, Nara Y, Ikeda N, Miyahara H, Mitobe H.
    Medinfo; 1995 Dec; 8 Pt 2():1230. PubMed ID: 8591414
    [Abstract] [Full Text] [Related]

  • 28. [Language of physicians' ECG conclusions].
    Zemtsovskiĭ EV.
    Kardiologiia; 1979 Apr; 19(4):93-8. PubMed ID: 374825
    [Abstract] [Full Text] [Related]

  • 29. Real-time 12-lead high-frequency QRS electrocardiography for enhanced detection of myocardial ischemia and coronary artery disease.
    Schlegel TT, Kulecz WB, DePalma JL, Feiveson AH, Wilson JS, Rahman MA, Bungo MW.
    Mayo Clin Proc; 2004 Mar; 79(3):339-50. PubMed ID: 15008608
    [Abstract] [Full Text] [Related]

  • 30.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 31.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 32.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 33. Errors of computer electrocardiography.
    RuDusky BM.
    Angiology; 1997 Dec; 48(12):1045-50. PubMed ID: 9404830
    [Abstract] [Full Text] [Related]

  • 34. Automated performance evaluation of real-time QRS-detection devices.
    Suppappola S, Sun Y.
    Biomed Instrum Technol; 1995 Dec; 29(1):41-9. PubMed ID: 7704081
    [Abstract] [Full Text] [Related]

  • 35. Integrate and fire pulse train automaton for QRS detection.
    Nallathambi G, Príncipe JC.
    IEEE Trans Biomed Eng; 2014 Feb; 61(2):317-26. PubMed ID: 24107919
    [Abstract] [Full Text] [Related]

  • 36. Deterministic logic versus software-based artificial neural networks in the diagnosis of atrial fibrillation.
    Yang TF, Devine B, Macfarlane PW.
    J Electrocardiol; 1993 Feb; 26 Suppl():90-4. PubMed ID: 8189154
    [Abstract] [Full Text] [Related]

  • 37. Automated serial ECG comparison improves computerized interpretation of 12-lead ECG.
    Gregg RE, Deluca DC, Chien CH, Helfenbein ED, Ariet M.
    J Electrocardiol; 2012 Feb; 45(6):561-5. PubMed ID: 22995382
    [Abstract] [Full Text] [Related]

  • 38.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 39. Evaluation of ECG interpretation systems: signal analysis.
    Zywietz C, van Bemmel JH, Degani R.
    Methods Inf Med; 1990 Sep; 29(4):298-307. PubMed ID: 2233376
    [Abstract] [Full Text] [Related]

  • 40.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]