These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
177 related items for PubMed ID: 22340459
1. Radiofrequency catheter ablation of atrioventricular nodal reentrant tachycardia guided by magnetic navigation system: a prospective randomized comparison with conventional procedure. Zhang YX, Lu CY, Xue Q, Li K, Yan W, Zhou SH. Chin Med J (Engl); 2012 Jan; 125(1):16-20. PubMed ID: 22340459 [Abstract] [Full Text] [Related]
2. Magnetic navigation in AV nodal re-entrant tachycardia study: early results of ablation with one- and three-magnet catheters. Thornton AS, Janse P, Theuns DA, Scholten MF, Jordaens LJ. Europace; 2006 Apr; 8(4):225-30. PubMed ID: 16627445 [Abstract] [Full Text] [Related]
3. Multicenter, randomized comparison between magnetically navigated and manually guided radiofrequency ablation of atrioventricular nodal reentrant tachycardia (the MagMa-AVNRT-trial). Reents T, Jilek C, Schuster P, Nölker G, Koch-Büttner K, Ammar-Busch S, Semmler V, Bourier F, Kottmaier M, Kornmayer M, Brooks S, Fichtner S, Kolb C, Deisenhofer I, Hessling G. Clin Res Cardiol; 2017 Dec; 106(12):947-952. PubMed ID: 28849269 [Abstract] [Full Text] [Related]
4. Remote magnetic navigation for catheter ablation of atrioventricular nodal reentrant tachycardia: a systematic review and meta-analysis. Shurrab M, Danon A, Crystal A, Arouny B, Tiong I, Lashevsky I, Newman D, Crystal E. Expert Rev Cardiovasc Ther; 2013 Jul; 11(7):829-36. PubMed ID: 23895026 [Abstract] [Full Text] [Related]
5. [Multi-center clinical trial on efficacy of national-made radiofrequency ablation catheter for the treatment of atrioventricular nodal reentrant tachycardia and atrioventricular reentrant tachycardia]. Wu SL, Fang XH, Jiang H, Ding YS, Multi-center Clinical Trial of Radiofrequency Ablation Catheter Collaboration Group. Zhonghua Xin Xue Guan Bing Za Zhi; 2010 Jan; 38(1):35-8. PubMed ID: 20398487 [Abstract] [Full Text] [Related]
6. Slow pathway radiofrequency ablation in patients with AVNRT: junctional rhythm is less frequent during magnetic navigation ablation than with the conventional technique. Ricard P, Latcu DG, Yaïci K, Zarqane N, Saoudi N. Pacing Clin Electrophysiol; 2010 Jan; 33(1):11-5. PubMed ID: 19895412 [Abstract] [Full Text] [Related]
7. Electrophysiologic characteristics and results of radiofrequency catheter ablation in elderly patients with atrioventricular nodal reentrant tachycardia. Haghjoo M, Arya A, Heidari A, Fazelifar AF, Sadr-Ameli MA. J Electrocardiol; 2007 Apr; 40(2):208-13. PubMed ID: 17069836 [Abstract] [Full Text] [Related]
8. Atrioventricular node reentrant tachycardia: Remote magnetic navigation ablation versus manual ablation - impact on operator fluoroscopy time. Parreira L, Marinheiro R, Carmo P, Cavaco D, Reis-Santos K, Amador P, Teixeira T, Soares AS, Costa F, Adragao P. Rev Port Cardiol (Engl Ed); 2019 Mar; 38(3):187-192. PubMed ID: 30979530 [Abstract] [Full Text] [Related]
9. [The catheter ablation of atrioventricular nodal reentry tachycardia: the results of a mixed electrophysiological/anatomical technic]. Sousa J, Brandão L, Carpinteiro L, Vagueiro MC. Rev Port Cardiol; 1995 Oct; 14(10):697-705. PubMed ID: 7492400 [Abstract] [Full Text] [Related]
10. Predictors of acute and long-term success of slow pathway ablation for atrioventricular nodal reentrant tachycardia: a single center series of 1,419 consecutive patients. Feldman A, Voskoboinik A, Kumar S, Spence S, Morton JB, Kistler PM, Sparks PB, Vohra JK, Kalman JM. Pacing Clin Electrophysiol; 2011 Aug; 34(8):927-33. PubMed ID: 21569056 [Abstract] [Full Text] [Related]
11. [Contact force control - the key to safe zero-fluoroscopy catheter ablation of atrioventricular nodal reentrant tachycardia]. Kerst G, Weig HJ, Weretka S, Seizer P, Hofbeck M, Gawaz M, Schreieck J. Dtsch Med Wochenschr; 2011 Sep; 136(39):1946-51. PubMed ID: 21935853 [Abstract] [Full Text] [Related]
12. [Radiofrequency ablation of the slow nodal pathway in cases of paroxysmal nodal reentry tachycardia]. Brugada J, Pelegrín J, Alvarez B, Matas M, Pava F, Navarro-López F. Rev Esp Cardiol; 1994 Apr; 47(4):240-6. PubMed ID: 8209091 [Abstract] [Full Text] [Related]
13. CRAVT: a prospective, randomized study comparing transvenous cryothermal and radiofrequency ablation in atrioventricular nodal re-entrant tachycardia. Kimman GP, Theuns DA, Szili-Torok T, Scholten MF, Res JC, Jordaens LJ. Eur Heart J; 2004 Dec; 25(24):2232-7. PubMed ID: 15589641 [Abstract] [Full Text] [Related]
16. Percutaneous catheter cryothermal ablation of atrioventricular nodal reentrant tachycardia: efficacy and safety of a new ablation technique. Riccardi R, Gaita F, Caponi D, Grossi S, Scaglione M, Caruzzo E, Di Donna P, Pistis G, Richiardi E, Giustetto C, Bocchiardo M. Ital Heart J; 2003 Jan; 4(1):35-43. PubMed ID: 12690919 [Abstract] [Full Text] [Related]
19. Safety and feasibility of single-catheter ablation using remote magnetic navigation for treatment of slow-fast atrioventricular nodal reentrant tachycardia compared to conventional ablation strategies. Akca F, Schwagten B, Theuns DA, Takens M, Musters P, Szili-Torok T. Acta Cardiol; 2013 Dec; 68(6):559-67. PubMed ID: 24579433 [Abstract] [Full Text] [Related]
20. [Reduction of radiological exposure time during radiofrequency catheter ablation procedures using a novel intracardiac localization system based on the Ohm's law]. Catanzariti D, Maines M, De Girolamo P, Cozzi F, Cemin C, Vergara G. Ital Heart J Suppl; 2004 Aug; 5(8):639-46. PubMed ID: 15554019 [Abstract] [Full Text] [Related] Page: [Next] [New Search]