These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


284 related items for PubMed ID: 22410036

  • 21. The Ability of esCCO and ECOM Monitors to Measure Trends in Cardiac Output During Alveolar Recruitment Maneuver After Cardiac Surgery: A Comparison with the Pulmonary Thermodilution Method.
    Thonnerieux M, Alexander B, Binet C, Obadia JF, Bastien O, Desebbe O.
    Anesth Analg; 2015 Aug; 121(2):383-91. PubMed ID: 25902321
    [Abstract] [Full Text] [Related]

  • 22. Multicenter study verifying a method of noninvasive continuous cardiac output measurement using pulse wave transit time: a comparison with intermittent bolus thermodilution cardiac output.
    Yamada T, Tsutsui M, Sugo Y, Sato T, Akazawa T, Sato N, Yamashita K, Ishihara H, Takeda J.
    Anesth Analg; 2012 Jul; 115(1):82-7. PubMed ID: 22467885
    [Abstract] [Full Text] [Related]

  • 23. Stroke volume variation derived by arterial pulse contour analysis is a good indicator for preload estimation during liver transplantation.
    Su BC, Tsai YF, Cheng CW, Yu HP, Yang MW, Lee WC, Lin CC.
    Transplant Proc; 2012 Mar; 44(2):429-32. PubMed ID: 22410035
    [Abstract] [Full Text] [Related]

  • 24. Arterial pulse cardiac output agreement with thermodilution in patients in hyperdynamic conditions.
    Della Rocca G, Costa MG, Chiarandini P, Bertossi G, Lugano M, Pompei L, Coccia C, Sainz-Barriga M, Pietropaoli P.
    J Cardiothorac Vasc Anesth; 2008 Oct; 22(5):681-7. PubMed ID: 18922423
    [Abstract] [Full Text] [Related]

  • 25. The impact of phenylephrine, ephedrine, and increased preload on third-generation Vigileo-FloTrac and esophageal doppler cardiac output measurements.
    Meng L, Tran NP, Alexander BS, Laning K, Chen G, Kain ZN, Cannesson M.
    Anesth Analg; 2011 Oct; 113(4):751-7. PubMed ID: 21821516
    [Abstract] [Full Text] [Related]

  • 26.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 27. Cardiac output derived from arterial pressure waveform analysis in patients undergoing cardiac surgery: validity of a second generation device.
    Mayer J, Boldt J, Wolf MW, Lang J, Suttner S.
    Anesth Analg; 2008 Mar; 106(3):867-72, table of contents. PubMed ID: 18292432
    [Abstract] [Full Text] [Related]

  • 28.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 29. Evaluation of an uncalibrated arterial pulse contour cardiac output monitoring system in cirrhotic patients undergoing liver surgery.
    Biancofiore G, Critchley LA, Lee A, Bindi L, Bisà M, Esposito M, Meacci L, Mozzo R, DeSimone P, Urbani L, Filipponi F.
    Br J Anaesth; 2009 Jan; 102(1):47-54. PubMed ID: 19059920
    [Abstract] [Full Text] [Related]

  • 30.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 31. Calibrated versus uncalibrated arterial pressure waveform analysis in monitoring cardiac output with transpulmonary thermodilution in patients with severe sepsis and septic shock: an observational study.
    Slagt C, Helmi M, Malagon I, Groeneveld AB.
    Eur J Anaesthesiol; 2015 Jan; 32(1):5-12. PubMed ID: 25387298
    [Abstract] [Full Text] [Related]

  • 32. FloTrac/Vigileo(TM) (third generation) and MostCare(®)/PRAM versus echocardiography for cardiac output estimation in vascular surgery.
    Romagnoli S, Ricci Z, Romano SM, Dimizio F, Bonicolini E, Quattrone D, De Gaudio R.
    J Cardiothorac Vasc Anesth; 2013 Dec; 27(6):1114-21. PubMed ID: 24055563
    [Abstract] [Full Text] [Related]

  • 33.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 34. Arterial pressure waveform analysis versus thermodilution cardiac output measurement during open abdominal aortic aneurysm repair: a prospective observational study.
    Montenij LJ, Buhre WF, de Jong SA, Harms JH, van Herwaarden JA, Kruitwagen CL, de Waal EE.
    Eur J Anaesthesiol; 2015 Jan; 32(1):13-9. PubMed ID: 25303970
    [Abstract] [Full Text] [Related]

  • 35. The accuracy of the Vigileo/FloTrac continuous cardiac output monitor.
    Zimmermann A, Kufner C, Hofbauer S, Steinwendner J, Hitzl W, Fritsch G, Schistek R, Kirnbauer M, Pauser G.
    J Cardiothorac Vasc Anesth; 2008 Jun; 22(3):388-93. PubMed ID: 18503926
    [Abstract] [Full Text] [Related]

  • 36. Noninvasive cardiac output determination using applanation tonometry-derived radial artery pulse contour analysis in critically ill patients.
    Compton F, Wittrock M, Schaefer JH, Zidek W, Tepel M, Scholze A.
    Anesth Analg; 2008 Jan; 106(1):171-4, table of contents. PubMed ID: 18165574
    [Abstract] [Full Text] [Related]

  • 37.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 38. Cardiac output monitoring: comparison of a new arterial pressure waveform analysis to the bolus thermodilution technique in patients undergoing off-pump coronary artery bypass surgery.
    Mehta Y, Chand RK, Sawhney R, Bhise M, Singh A, Trehan N.
    J Cardiothorac Vasc Anesth; 2008 Jun; 22(3):394-9. PubMed ID: 18503927
    [Abstract] [Full Text] [Related]

  • 39.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 40.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]


    Page: [Previous] [Next] [New Search]
    of 15.