These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


229 related items for PubMed ID: 22465444

  • 1. DNAzyme-based turn-on chemiluminescence assays in homogenous media.
    Zhou M, Liu Y, Tu Y, Tao G, Yan J.
    Biosens Bioelectron; 2012 May 15; 35(1):489-492. PubMed ID: 22465444
    [Abstract] [Full Text] [Related]

  • 2. A homogeneous hemin/G-quadruplex DNAzyme based turn-on chemiluminescence aptasensor for interferon-gamma detection via in-situ assembly of luminol functionalized gold nanoparticles, deoxyribonucleic acid, interferon-gamma and hemin.
    Jiang J, He Y, Yu X, Zhao J, Cui H.
    Anal Chim Acta; 2013 Aug 12; 791():60-4. PubMed ID: 23890607
    [Abstract] [Full Text] [Related]

  • 3. An ultrasensitive electrochemical aptasensor for thrombin based on the triplex-amplification of hemin/G-quadruplex horseradish peroxidase-mimicking DNAzyme and horseradish peroxidase decorated FeTe nanorods.
    Jiang L, Yuan R, Chai Y, Yuan Y, Bai L, Wang Y.
    Analyst; 2013 Mar 07; 138(5):1497-503. PubMed ID: 23340527
    [Abstract] [Full Text] [Related]

  • 4. An enhanced chemiluminescence resonance energy transfer system based on target recycling G-guadruplexes/hemin DNAzyme catalysis and its application in ultrasensitive detection of DNA.
    Chen J, Huang Y, Vdovenko M, Sakharov IY, Su G, Zhao S.
    Talanta; 2015 Jun 01; 138():59-63. PubMed ID: 25863372
    [Abstract] [Full Text] [Related]

  • 5. A chemiluminescence aptasensor for thrombin detection based on aptamer-conjugated and hemin/G-quadruplex DNAzyme signal-amplified carbon fiber composite.
    Sun Y, Wang X, Xu H, Ding C, Lin Y, Luo C, Wei Q.
    Anal Chim Acta; 2018 Dec 28; 1043():132-141. PubMed ID: 30392661
    [Abstract] [Full Text] [Related]

  • 6. Electrochemical aptasensor based on the dual-amplification of G-quadruplex horseradish peroxidase-mimicking DNAzyme and blocking reagent-horseradish peroxidase.
    Yuan Y, Gou X, Yuan R, Chai Y, Zhuo Y, Mao L, Gan X.
    Biosens Bioelectron; 2011 Jun 15; 26(10):4236-40. PubMed ID: 21536422
    [Abstract] [Full Text] [Related]

  • 7. A novel electrochemical aptasensor for highly sensitive detection of thrombin based on the autonomous assembly of hemin/G-quadruplex horseradish peroxidase-mimicking DNAzyme nanowires.
    Xie S, Chai Y, Yuan Y, Bai L, Yuan R.
    Anal Chim Acta; 2014 Jun 17; 832():51-7. PubMed ID: 24890694
    [Abstract] [Full Text] [Related]

  • 8. Label-free and amplified electrochemical detection of cytokine based on hairpin aptamer and catalytic DNAzyme.
    Zhang H, Jiang B, Xiang Y, Chai Y, Yuan R.
    Analyst; 2012 Feb 21; 137(4):1020-3. PubMed ID: 22193340
    [Abstract] [Full Text] [Related]

  • 9. Photoinduced electron transfer (PET) based label-free aptasensor for platelet-derived growth factor-BB and its logic gate application.
    Wang G, Zhu Y, Chen L, Zhang X.
    Biosens Bioelectron; 2015 Jan 15; 63():552-557. PubMed ID: 25150781
    [Abstract] [Full Text] [Related]

  • 10. DNA nanotetrahedron linked dual-aptamer based voltammetric aptasensor for cardiac troponin I using a magnetic metal-organic framework as a label.
    Luo Z, Sun D, Tong Y, Zhong Y, Chen Z.
    Mikrochim Acta; 2019 May 23; 186(6):374. PubMed ID: 31123904
    [Abstract] [Full Text] [Related]

  • 11. Homogeneous assay of target molecules based on chemiluminescence resonance energy transfer (CRET) using DNAzyme-linked aptamers.
    Mun H, Jo EJ, Li T, Joung HA, Hong DG, Shim WB, Jung C, Kim MG.
    Biosens Bioelectron; 2014 Aug 15; 58():308-13. PubMed ID: 24658027
    [Abstract] [Full Text] [Related]

  • 12. Hemin/G-quadruplex-based DNAzyme concatamers for in situ amplified impedimetric sensing of copper(II) ion coupling with DNAzyme-catalyzed precipitation strategy.
    Xu M, Gao Z, Wei Q, Chen G, Tang D.
    Biosens Bioelectron; 2015 Dec 15; 74():1-7. PubMed ID: 26093122
    [Abstract] [Full Text] [Related]

  • 13. Conformational switch for cisplatin with hemin/G-quadruplex DNAzyme supersandwich structure.
    Wang G, He X, Chen L, Zhu Y, Zhang X, Wang L.
    Biosens Bioelectron; 2013 Dec 15; 50():210-6. PubMed ID: 23859921
    [Abstract] [Full Text] [Related]

  • 14. A chemiluminescence biosensor for lysozyme detection based on aptamers and hemin/G-quadruplex DNAzyme modified sandwich-rod carbon fiber composite.
    Sun Y, Lin Y, Han R, Wang X, Luo C.
    Talanta; 2019 Aug 01; 200():57-66. PubMed ID: 31036225
    [Abstract] [Full Text] [Related]

  • 15. An enzyme-free and label-free signal-on aptasensor based on DNAzyme-driven DNA walker strategy.
    Lei S, Xu L, Liu Z, Zou L, Li G, Ye B.
    Anal Chim Acta; 2019 Nov 12; 1081():59-64. PubMed ID: 31446964
    [Abstract] [Full Text] [Related]

  • 16. Amplified biosensing using the horseradish peroxidase-mimicking DNAzyme as an electrocatalyst.
    Pelossof G, Tel-Vered R, Elbaz J, Willner I.
    Anal Chem; 2010 Jun 01; 82(11):4396-402. PubMed ID: 20441165
    [Abstract] [Full Text] [Related]

  • 17. A pseudo triple-enzyme cascade amplified aptasensor for thrombin detection based on hemin/G-quadruplex as signal label.
    Yi H, Xu W, Yuan Y, Bai L, Wu Y, Chai Y, Yuan R.
    Biosens Bioelectron; 2014 Apr 15; 54():415-20. PubMed ID: 24296062
    [Abstract] [Full Text] [Related]

  • 18. DNA nanotetrahedron-assisted electrochemical aptasensor for cardiac troponin I detection based on the co-catalysis of hybrid nanozyme, natural enzyme and artificial DNAzyme.
    Sun D, Lin X, Lu J, Wei P, Luo Z, Lu X, Chen Z, Zhang L.
    Biosens Bioelectron; 2019 Oct 01; 142():111578. PubMed ID: 31422223
    [Abstract] [Full Text] [Related]

  • 19. A novel "dual-potential" ratiometric electrochemiluminescence DNA sensor based on enhancing and quenching effect by G-quadruplex / hemin and Au-Luminol bifunctional nanoparticles.
    Wang Y, Shan D, Wu G, Wang H, Ru F, Zhang X, Li L, Qian Y, Lu X.
    Biosens Bioelectron; 2018 May 30; 106():64-70. PubMed ID: 29414090
    [Abstract] [Full Text] [Related]

  • 20. Amplified electrochemical hydrogen peroxide reduction based on hemin/G-quadruplex DNAzyme as electrocatalyst at gold particles modified heated copper disk electrode.
    Wu SH, Tang Y, Chen L, Ma XG, Tian SM, Sun JJ.
    Biosens Bioelectron; 2015 Nov 15; 73():41-46. PubMed ID: 26043314
    [Abstract] [Full Text] [Related]


    Page: [Next] [New Search]
    of 12.