These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


196 related items for PubMed ID: 22540325

  • 1. Commercially pure titanium implants with surfaces modified by laser beam with and without chemical deposition of apatite. Biomechanical and topographical analysis in rabbits.
    Queiroz TP, Souza FÁ, Guastaldi AC, Margonar R, Garcia-Júnior IR, Hochuli-Vieira E.
    Clin Oral Implants Res; 2013 Aug; 24(8):896-903. PubMed ID: 22540325
    [Abstract] [Full Text] [Related]

  • 2. In vivo evaluation of cp Ti implants with modified surfaces by laser beam with and without hydroxyapatite chemical deposition and without and with thermal treatment: topographic characterization and histomorphometric analysis in rabbits.
    Queiroz TP, de Molon RS, Souza FÁ, Margonar R, Thomazini AH, Guastaldi AC, Hochuli-Vieira E.
    Clin Oral Investig; 2017 Mar; 21(2):685-699. PubMed ID: 27530186
    [Abstract] [Full Text] [Related]

  • 3. Surface and biomechanical study of titanium implants modified by laser with and without hydroxyapatite coating, in rabbits.
    Sisti KE, de Rossi R, Antoniolli AM, Aydos RD, Guastaldi AC, Queiroz TP, Garcia IR, Piattelli A, Tavares HS.
    J Oral Implantol; 2012 Jun; 38(3):231-7. PubMed ID: 20690851
    [Abstract] [Full Text] [Related]

  • 4. Biological performance of chemical hydroxyapatite coating associated with implant surface modification by laser beam: biomechanical study in rabbit tibias.
    Faeda RS, Tavares HS, Sartori R, Guastaldi AC, Marcantonio E.
    J Oral Maxillofac Surg; 2009 Aug; 67(8):1706-15. PubMed ID: 19615586
    [Abstract] [Full Text] [Related]

  • 5. The role of titanium implant surface modification with hydroxyapatite nanoparticles in progressive early bone-implant fixation in vivo.
    Lin A, Wang CJ, Kelly J, Gubbi P, Nishimura I.
    Int J Oral Maxillofac Implants; 2009 Aug; 24(5):808-16. PubMed ID: 19865620
    [Abstract] [Full Text] [Related]

  • 6. In vivo comparison of bone formation on titanium implant surfaces coated with biomimetically deposited calcium phosphate or electrochemically deposited hydroxyapatite.
    Yang GL, He FM, Song E, Hu JA, Wang XX, Zhao SF.
    Int J Oral Maxillofac Implants; 2010 Aug; 25(4):669-80. PubMed ID: 20657861
    [Abstract] [Full Text] [Related]

  • 7. Biomedical Ti-Mo alloys with surface machined and modified by laser beam: biomechanical, histological, and histometric analysis in rabbits.
    Oliveira NT, Guastaldi FP, Perrotti V, Hochuli-Vieira E, Guastaldi AC, Piattelli A, Iezzi G.
    Clin Implant Dent Relat Res; 2013 Jun; 15(3):427-37. PubMed ID: 21554530
    [Abstract] [Full Text] [Related]

  • 8. Effect of electrochemically deposited nanohydroxyapatite on bone bonding of sandblasted/dual acid-etched titanium implant.
    He F, Yang G, Wang X, Zhao S.
    Int J Oral Maxillofac Implants; 2009 Jun; 24(5):790-9. PubMed ID: 19865618
    [Abstract] [Full Text] [Related]

  • 9. Osseointegration of zirconia implants with different surface characteristics: an evaluation in rabbits.
    Hoffmann O, Angelov N, Zafiropoulos GG, Andreana S.
    Int J Oral Maxillofac Implants; 2012 Jun; 27(2):352-8. PubMed ID: 22442775
    [Abstract] [Full Text] [Related]

  • 10. The effect of hydroxyapatite nanocrystals on early bone formation surrounding dental implants.
    Svanborg LM, Hoffman M, Andersson M, Currie F, Kjellin P, Wennerberg A.
    Int J Oral Maxillofac Surg; 2011 Mar; 40(3):308-15. PubMed ID: 21111575
    [Abstract] [Full Text] [Related]

  • 11. Hydroxyapatite and collagen combination-coated dental implants display better bone formation in the peri-implant area than the same combination plus bone morphogenetic protein-2-coated implants, hydroxyapatite only coated implants, and uncoated implants.
    Lee SW, Hahn BD, Kang TY, Lee MJ, Choi JY, Kim MK, Kim SG.
    J Oral Maxillofac Surg; 2014 Jan; 72(1):53-60. PubMed ID: 24331565
    [Abstract] [Full Text] [Related]

  • 12. Histomorphometric analysis of hydroxyapatite-coated implants in rabbit cortical bone using longitudinal and transverse histologic sections.
    Rebollal J, Soares Gde A, Vidigal GM.
    Implant Dent; 2010 Apr; 19(2):137-44. PubMed ID: 20386217
    [Abstract] [Full Text] [Related]

  • 13. Early bone healing around 2 different experimental, HA grit-blasted, and dual acid-etched titanium implant surfaces. A pilot study in rabbits.
    Gobbato L, Arguello E, Martin IS, Hawley CE, Griffin TJ.
    Implant Dent; 2012 Dec; 21(6):454-60. PubMed ID: 23149502
    [Abstract] [Full Text] [Related]

  • 14. Osseointegration evaluation of laser-deposited titanium dioxide nanoparticles on commercially pure titanium dental implants.
    Azzawi ZGM, Hamad TI, Kadhim SA, Naji GA.
    J Mater Sci Mater Med; 2018 Jun 26; 29(7):96. PubMed ID: 29946975
    [Abstract] [Full Text] [Related]

  • 15. Comparative in vivo study of commercially pure Ti implants with surfaces modified by laser with and without silicate deposition: biomechanical and scanning electron microscopy analysis.
    Souza FA, Queiroz TP, Guastaldi AC, Garcia-Júnior IR, Magro-Filho O, Nishioka RS, Sisti KE, Sonoda CK.
    J Biomed Mater Res B Appl Biomater; 2013 Jan 26; 101(1):76-84. PubMed ID: 23090936
    [Abstract] [Full Text] [Related]

  • 16. Biomechanical comparison of different surface modifications for dental implants.
    Ferguson SJ, Langhoff JD, Voelter K, von Rechenberg B, Scharnweber D, Bierbaum S, Schnabelrauch M, Kautz AR, Frauchiger VM, Mueller TL, van Lenthe GH, Schlottig F.
    Int J Oral Maxillofac Implants; 2008 Jan 26; 23(6):1037-46. PubMed ID: 19216272
    [Abstract] [Full Text] [Related]

  • 17. Comparison between bioactive fluoride modified and bioinert anodically oxidized implant surfaces in early bone response using rabbit tibia model.
    Choi JY, Lee HJ, Jang JU, Yeo IS.
    Implant Dent; 2012 Apr 26; 21(2):124-8. PubMed ID: 22382750
    [Abstract] [Full Text] [Related]

  • 18. Biomechanical and histomorphometric evaluation of osseointegration of fusion-sputtered zirconia implants.
    Salem NA, Abo Taleb AL, Aboushelib MN.
    J Prosthodont; 2013 Jun 26; 22(4):261-7. PubMed ID: 23107438
    [Abstract] [Full Text] [Related]

  • 19. Effects of ion beam-assisted deposition of hydroxyapatite on the osseointegration of endosseous implants in rabbit tibiae.
    Jung YC, Han CH, Lee IS, Kim HE.
    Int J Oral Maxillofac Implants; 2001 Jun 26; 16(6):809-18. PubMed ID: 11769831
    [Abstract] [Full Text] [Related]

  • 20. Histologic comparison of a thermal dual-etched implant surface to machined, TPS, and HA surfaces: bone contact in vivo in rabbits.
    London RM, Roberts FA, Baker DA, Rohrer MD, O'Neal RB.
    Int J Oral Maxillofac Implants; 2002 Jun 26; 17(3):369-76. PubMed ID: 12074452
    [Abstract] [Full Text] [Related]


    Page: [Next] [New Search]
    of 10.