These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


129 related items for PubMed ID: 2254700

  • 1. Accuracy in clinical arrhythmia detection of a real-time Holter system (Oxford Medilog 4500).
    Lanza GA, Lucente M, Rebuzzi AG, Cortellessa MC, Tamburi S, Mancuso P, Neri R, Manzoli U.
    J Electrocardiol; 1990 Oct; 23(4):301-6. PubMed ID: 2254700
    [Abstract] [Full Text] [Related]

  • 2. Real-time analysis ambulatory electrocardiography--clinical evaluation of cardiac arrhythmias by the Aegis system.
    Kennedy HL, Sprague MK, Shriver KK, Smith SC, Whitlock JA, Wiens RD.
    J Electrocardiol; 1987 Jul; 20(3):247-54. PubMed ID: 3655596
    [Abstract] [Full Text] [Related]

  • 3. Holter triage ambulatory ECG analysis. Accuracy and time efficiency.
    Cooper DH, Kennedy HL, Lyyski DS, Sprague MK.
    J Electrocardiol; 1996 Jan; 29(1):33-8. PubMed ID: 8808523
    [Abstract] [Full Text] [Related]

  • 4.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 5. [The predictive value for major arrhythmic events of ventricular arrhythmias, particularly nonsustained ventricular tachycardias, in the subacute phase of a fibrinolyzed infarct. An analysis of GISSI-2 data. Gruppo Italiano per lo Studio della Streptochinasi nell'Infarto Miocardico].
    Giani P, Avanzini F, Bagliani G, Galati A, Pucci P, Santoro E.
    G Ital Cardiol; 1995 Jan; 25(1):77-87. PubMed ID: 7642014
    [Abstract] [Full Text] [Related]

  • 6. [Beat-by-beat validation of the Oxford Medilog 4500, a 24-hour long-term ECG system with real-time analysis].
    Elfner R, Buss J, Kraatz J, Heene DL.
    Z Kardiol; 1987 Aug; 76(8):492-500. PubMed ID: 2445117
    [Abstract] [Full Text] [Related]

  • 7. The quality of ECG data acquisition, and diagnostic performance of a novel adhesive patch for ambulatory cardiac rhythm monitoring in arrhythmia detection.
    Karaoğuz MR, Yurtseven E, Aslan G, Deliormanlı BG, Adıgüzel Ö, Gönen M, Li KM, Yılmaz EN.
    J Electrocardiol; 2019 Aug; 54():28-35. PubMed ID: 30851474
    [Abstract] [Full Text] [Related]

  • 8. [Analysis of the accuracy of the Holter system ICR 6201-G3].
    Schmidt G, Goedel-Meinen L, Weixel G, Jahns G, Ulm K.
    Z Kardiol; 1986 Apr; 75(4):211-4. PubMed ID: 3727660
    [Abstract] [Full Text] [Related]

  • 9. Enhanced detection of cardiac arrhythmias utilizing 14-day continuous ECG patch monitoring.
    Liu CM, Chang SL, Yeh YH, Chung FP, Hu YF, Chou CC, Hung KC, Chang PC, Liao JN, Chan YH, Lo LW, Wu LS, Lin YJ, Wen MS, Chen SA.
    Int J Cardiol; 2021 Jun 01; 332():78-84. PubMed ID: 33727122
    [Abstract] [Full Text] [Related]

  • 10. Spectrum and prognostic significance of arrhythmias on ambulatory Holter electrocardiogram in hypertrophic cardiomyopathy.
    Adabag AS, Casey SA, Kuskowski MA, Zenovich AG, Maron BJ.
    J Am Coll Cardiol; 2005 Mar 01; 45(5):697-704. PubMed ID: 15734613
    [Abstract] [Full Text] [Related]

  • 11. Risk Prediction for Arrhythmias by Heart Rate Deceleration Runs in Patients with Chronic Obstructive Pulmonary Disease.
    Kong ZB, Wang XD, Shen SR, Liu H, Zhou L, Chen B, Chen Z, Yin SJ.
    Int J Chron Obstruct Pulmon Dis; 2020 Mar 01; 15():585-593. PubMed ID: 32231431
    [Abstract] [Full Text] [Related]

  • 12. Experience with an ambulatory 12-lead Holter recording system for evaluation of pediatric dysrhythmias.
    Emmel M, Sreeram N, Schickendantz S, Brockmeier K.
    J Electrocardiol; 2006 Apr 01; 39(2):188-93. PubMed ID: 16580418
    [Abstract] [Full Text] [Related]

  • 13. Arrhythmias Seen in Baseline 24-Hour Holter ECG Recordings in Healthy Normal Volunteers During Phase 1 Clinical Trials.
    Hingorani P, Karnad DR, Rohekar P, Kerkar V, Lokhandwala YY, Kothari S.
    J Clin Pharmacol; 2016 Jul 01; 56(7):885-93. PubMed ID: 26626443
    [Abstract] [Full Text] [Related]

  • 14. Deceleration and Acceleration Capacities in Risk Stratification for Arrhythmias in Patients With Chronic Obstructive Pulmonary Disease.
    Buzea CA, Dan GA, Dan AR, Delcea C, Balea MI, Gologanu D, Popescu RA, Dobranici M.
    Am J Ther; 2017 Jul 01; 24(1):e44-e51. PubMed ID: 27148677
    [Abstract] [Full Text] [Related]

  • 15. Usefulness of extended holter ECG monitoring for serious arrhythmia detection in patients with heart failure and sleep apnea.
    Uznańska-Loch B, Trzos E, Wierzbowska-Drabik K, Smigielski J, Rechciński T, Cieślik-Guerra U, Kasprzak JD, Kurpesa M.
    Ann Noninvasive Electrocardiol; 2013 Mar 01; 18(2):163-9. PubMed ID: 23530487
    [Abstract] [Full Text] [Related]

  • 16. Identifying arrhythmias in adults with congenital heart disease by 24-h ambulatory electrocardiography.
    Rodriguez FH, Moodie DS, Neeland M, Adams GJ, Snyder CS.
    Pediatr Cardiol; 2012 Apr 01; 33(4):591-5. PubMed ID: 22318853
    [Abstract] [Full Text] [Related]

  • 17. [Relationship between ventricular arrhythmia and clinical and echocardiographic parameters in hypertensive patients].
    Pedro E, Falcão M, Bonhorst D, Gomes RS.
    Rev Port Cardiol; 1992 Jan 01; 11(1):29-34. PubMed ID: 1599697
    [Abstract] [Full Text] [Related]

  • 18. Initial clinical experience with a new arrhythmia detection algorithm in dual chamber implantable cardioverter defibrillators.
    Theuns D, Klootwijk AP, Kimman GP, Szili-Török T, Roelandt JR, Jordaens L.
    Europace; 2001 Jul 01; 3(3):181-6. PubMed ID: 11467458
    [Abstract] [Full Text] [Related]

  • 19. Significance of arrhythmias during the first 24 hours of acute myocardial infarction treated with alteplase and effect of early administration of a beta-blocker or a bradycardiac agent on their incidence.
    Heidbüchel H, Tack J, Vanneste L, Ballet A, Ector H, Van de Werf F.
    Circulation; 1994 Mar 01; 89(3):1051-9. PubMed ID: 8124790
    [Abstract] [Full Text] [Related]

  • 20. Automated Method for Discrimination of Arrhythmias Using Time, Frequency, and Nonlinear Features of Electrocardiogram Signals.
    Hajeb-Mohammadalipour S, Ahmadi M, Shahghadami R, Chon KH.
    Sensors (Basel); 2018 Jun 29; 18(7):. PubMed ID: 29966276
    [Abstract] [Full Text] [Related]


    Page: [Next] [New Search]
    of 7.